66
|
City Series CV72E
installation
Wiring Diagram
1
2
3
4
5
7
9
11
10
12
14
15
17
18
19
20
21
22
23
27
28
24
26
25
6
13
16
29
8
No electrical power supply is required for the gas control to operate. 120 Volt
AC power is needed for the lights. A receptacle box, receptacle and cover are
provided and located on the left hand side of the unit, under the outer base panel.
Electrical power must be brought to the appliance by a licensed
electrician.
Item Part #
Description
1
911-276
Pilot Assembly NG
911-277
Pilot Assembly LP
W840470
Pilot Gasket
2
911-038
Spark Electrode
3
911-037
Flame Sensor Electrode
4
911-266/P
PFII IFC Board
5
911-192
Power Harness w/Aux
Connector
6
N/A
Main Line
7
911-182
Fuse
8
911-208
Oven Lamp w/Wires
9
911-209
Wire 2 pos. IFC Fan
10
911-177
Wire 4 pos. IFC Fan &
Light
Item Part #
Description
11
N/A
Load
12
N/A
Diagnostic Interface
13
N/A
Combustion Blower
14
N/A
Lamp
15
N/A
User Interface
16
N/A
Comfort Fan
17
N/A
Split Flow
18
N/A
Motor
19
N/A
Switch
20
911-181
Battery Holder WIre
Harness
21
911-187
Battery Holder
22
911-190
Flame Modulator-NG
Item Part #
Description
22
911-191
Flame Modulator LP
23
N/A
Battery Connection
24
N/A
Adjustment Screw
25
911-242
Outlet Pressure Ports
26
911-173
Valve Wire Harness
27
911-188
Valve NG
911-189
Valve LP
28
911-193
Connector w/Jumper
CA
UTION
• Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
• Ensure that the wires do not touch any hot surfaces and are away from sharp edges.
• The IFC (Intermittent Fireplace Control) serves as the power source for this unit when plugged into a 120-volt receptacle.
The 4 x AA batteries in the battery holder are recommended as a backup in case 120-volt power is lost within the home.
• If replacing any of the wiring or wiring harnesses supplied with the appliance, you must purchase the same wiring or wiring
harnesses that came with the appliance. Do not substitute wiring.
• This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be
plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug.