29

parts list

5

1

12

2

11

18

13  

9  

MAIN ASSEMBLY CI1200

        Part #          Description

1)  156-004 

Door Hinge

2)  940-366/P  Neoceram Glass 

3)  948-155 

Hinge Pin Lower

4)  936-238 

Adhesive Tape Gasket

5)  156-054 

Glass Retainer Clips / Screws (set of 2)

6)  * 

 

Screws - 10-24 x 3/8"

9)  156-514 

Door Handle Assembly

11)  156-519 

Door Catch

12)  156-513 

Door Assembly Metallic Black (no glass)

 

846-570 

Med. Density Door Gasket Kit

13)  156-241 

Cast Handle

14)  074-954 

Air Tube - 1"  (Qty: 1)

15)  033-953 

Air Tube - 3/4"  (Qty: 1)

16)  073-955 

Baffle (2/set) 

17)  171-932 

Standard Flue Adaptor

 

171-936 

Offset Flue Adaptor

18)  156-060N  Draft plate arm

19)  820-483 

Stainless smoke deflector

 

*Not available as a replacement part.

16

14

15

17

19

Содержание CI1200 Alterra

Страница 1: ... 540 CI1200 CI1250 Alterra Wood Inserts 09 15 15 Owner s Installation Manual Tested by Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference French Manual Download http ow ly MuZyo ...

Страница 2: ... where the majority of the chimney is within the building envelope and fully lined It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual or if any parts are removed It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual CAUTION BURN UNTREATED WOOD ONL...

Страница 3: ...llation Into a Masonry Fireplace 13 Installation Into a Factory Built Fireplace 13 Stainless steel smoke deflector Installation 14 Cast faceplate installation 15 3 piece backing plate installation 18 Door reversal 19 Brick Flue Baffle Secondary Air Tube Installation 20 Firebrick Assembly 20 Draft Control 20 OPERATING INSTRUCTIONS Seasoned Wood 21 First Fire 22 Fan Operation CS1250 Only 23 Cord rev...

Страница 4: ... PAS TOUCHER GARDEZ LES EN FANTS VÊTEMENTS ET MEUBLES AU LOIN UN CONTACT AVEC LE PEAU PEUT OC CASIONER DES BRULURES BRÛLURES CUTANÉES LIRE CETTE ÉTIQUETTE CAUTION ATTENTION ADJACENT SIDEWALL A 15in 380mm MANTLE B 20in 510mm TOP FACING C 14in 355 mm SIDE FACING D 7 375in 185mm INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS INSTALL AND USE ONLY IN ...

Страница 5: ...BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA UNITED STATES ENVIRONMENTAL PROTECTION AGENCY CERTIFIED TO COMPLY WITH JULY 1990 PARTICULATE EMISSION STANDARDS JAN FEB MAR APR MAY JUN JUL AUG SEPT OCT NOV DEC 2015 2016 2017 Duplicate Serial MADE IN CANADA 367 DATE OF MANUFACTURE INSTALLER ET UTILISER SELONS LES INSTRUCTIONS DU FABRICANT INSTALLER ET UTILISER ...

Страница 6: ... 58mm 19 9 16 498mm 9 9 16 15 381mm 18 13 16 478mm 17 11 16 449mm 22 9 16 574mm 244mm 21 3 8 543mm 15 1 16 383mm 9 15 16 250mm 17 432mm NOTE Before assembling your Insert use these dimensions to ensure appro priateclearanceswillbemet referto MasonryandFactoryBuiltFireplace Clearances section 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 14 1 8 from flue centerline to rear of faceplate 16 15 16 430m...

Страница 7: ...381mm 22 13 16 579mm 250mm 20 1 2 521mm UNIT DIMENSIONS CI1250 WITH STANDARD BLOWER 6 152mm Diameter STANDARD FLUE ADAPTOR 171 932 6 152mm Diameter OFFSET FLUE ADAPTOR 171 936 14 1 8 from flue centerline to rear of faceplate 16 15 16 430mm NOTE Before assembling your Insert use these dimensions to ensure appro priateclearanceswillbemet referto MasonryandFactoryBuiltFireplace Clearances section ...

Страница 8: ... Insert 8 dimensions OPTIONAL BACKING PLATE DIMENSIONS 40 1016mm 40 1016mm 37 940mm 37 914mm 29 1 2 749mm 27 686mm 26 660mm 23 5 8 600mm CI1250 Standard CI1250 Custom Minimum Dimensions CI1200 Custom Minimum Dimensions CI1200 Standard ...

Страница 9: ...lower 1 Read all instructions before installing and us ing your fireplace insert Install and use only in accordance with manufacturer s installation and operating instructions 2 Check your local building codes Building Inspection Department You may require a permit before installing your insert Be aware that local codes and regulations may override some items in the manual WARNING Careless install...

Страница 10: ...brick 1 C 1 1 25 0 80 1 8 mineralboardofk 0 29 therefore Rmin bd 1 0 29 x 0 125 0 431 Total R Rbrick Rmineral board 0 8 0 431 1 231 Step c CompareproposedsystemRof1 231tospeci fied R of 0 893 Since proposed system R is greaterthanrequired thesystemisacceptable DEFINITIONS Thermal Conductance C Btu W hr ft2 o F m2 K Thermal Conductivity k Btu inch W Btu hr ft3 o F m K hr ft o F Thermal Resistance R...

Страница 11: ...ng when level slightly above the required height Secure adaptor using 3 screws 1 in the front and 1 each on the left and right side Flex Liner Diagram 1 Yourinsertisveryheavyandwillrequiretwoorthreepeopletomove it into position Whenhandlingcastparts pleasehandlewithcareastheycanbedamaged 1 Open door to a 45 angle 2 Holding door firmly from top and bottom lift door up and off to remove 3 Lift the u...

Страница 12: ... flue adaptor as shown in diagram 4 While sliding the unit into place pull on the rod to ensure that the flue adaptor is properly engaged See diagram 5 Pull Rod 10 Ensure that the unit is still level 11 To complete the installation and to ensure a secure fit and connection of the flue adaptor to the insert it is essential that the two bolts flat wash ers and lock washers supplied with packaged man...

Страница 13: ...stainless steel rigid or flexible liner pipe is routed from the insert outlet collar to the top of the chimney Regency highly recommends the use of a full liner as the safest installation and provides the most optimum performance Your retailer should be able to help you decide which system would be the best for your application In Canada this fireplace insert must be in stalledwithacontinuouschimn...

Страница 14: ...h 2 hand tightened bolts To replace the deflector loosen off both bolts and slide defector upward and out Install new defector and hand tighten bolts Ensure positive location of the defector prior to hand tightening WARNING Operation of the unit with out proper installation of smoke deflector will void warranty Smoke deflector is installed through the door opening in location shown in diagram Smok...

Страница 15: ... the bracket on the unit as shown below Line up the left side casting bracket with the left side bracket on the unit Note the CI1200 right left sides are reversible 4 Secure the left cast surround with the two bolts removed in Step 2 5 Repeat Steps 2 and 4 to install right cast surround CI1250 Only 3 Install fan controls into left surround with 2 screws as shown below Note Left side faceplate when...

Страница 16: ...Move the damper control lever to the right so it is out of the way Note If the fan power cord needs to be re routed to the right side of the unit go to step 16 before installing the lower cast surround piece 13 Line up the brackets on the lower cast surround piece with the lower holes in the bracket on the unit Replace two 2 screws removed in step 9 14 Before tightening screws adjust the position ...

Страница 17: ...routed to the right side of the unit if necessary Before installing the lower cast surround run the cord between the left cast surround and the unit Then run the cord along the lower part of the lower cast surround and out in between the right cast and the unit 17 With the cord re routed follow steps 13 15 to complete the installa tion ...

Страница 18: ... 5 Standard backing plate shown on the CI1250 2 The pointed end of the screws should be facing the front of the back ing plate 3 Install 2 clips to the back of the top cast faceplate with hex bolts If the unit is already installed remove the top cast faceplate from the unit if access is too difficult see Cast Faceplate Installation in the owners manual for instructions 4 Slide the backing plate ov...

Страница 19: ... leakage 3 Remove the 2 bolts securing the door catch assembly to the unit 6 Remove the glass from the door and flip it around 180 so the painted strip is at the bottom of the door 7 Flip the handle around 180 and reattach to the door with 2 botls 4 Flip the door hinge 180 install on the left side of the unit with 2 bolts 5 Reattach the door catch assembly on the right side with 2 bolts from step ...

Страница 20: ...into place with a hammer A tighter fit will ensure the tube will not move when the unit is burning 2 Slide the left baffle brick over the front air tube and then slide it back over the rear air tube 3 Tilt the left baffle brick up on top of the side channel and it will leave enough room to posi tion the right baffle brick in the same manner as Step 1 above Then reposition the left baffle brick fla...

Страница 21: ... sides Softer woods like pine spruce and poplar aspen that is cut split and stacked properly in the early spring maybe be ready for burning in the fall Extremely hard woods like oak and maple and large pieces of firewood may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many ind...

Страница 22: ...adequate ventilation while this tempo rary condition exists Burning the insert at a very high temperature the first few times may damage the paint Burn fires at a moderate level the first few days 8 Do not place anything on the insert top during the curing process This may result in damage to your paint finish 9 Duringthefirstfewhoursitmaybemoredifficult to start the fire As you dry out your fire ...

Страница 23: ...r Low for fan speed The automatic temperature sensor will engage the blower when the unit is at temperature and will shut off the blower once the fire has gone out and the unit has cooled to below a useful heat output range To manually operate the fan system push the first switch to Man and second switch to either high or Low This will bypass the sensing device and allow full control of the fan Sw...

Страница 24: ...ombustible materials pending final disposal If the ashes are disposed of by burial in soil or otherwise locally dispersed theyshouldberetainedintheclosedcontaineruntil all cinders have thoroughly cooled Other waste should not be placed in the ash container SOME SAFETY GUIDELINES 1 Neverusegasoline gasolinetypelanternfuels kerosene charcoallighterfuel orsimilarliquids orchemicalstostartor freshenup...

Страница 25: ...pen and check the clearance to the Right Hand Cast Side Iftightorrubbing loosenthe 7 16nutsandadjusttheclearance and then re tighten GLASS REPLACEMENT Allow the stove to cool before removing or replacing glass Remove the door from the stove and remove the glass retainer Use caution when removing broken glass to avoid injury When placing the replacement glass in the door make sure that the glass ga...

Страница 26: ...e spacer washer shown in the diagram below will allow the catch to be moved closer to the door frame causing a tighter seal Remove and replace the nuts washer and spacer as shown TO REMOVE THE FAN 1 See next page Maintenance The sealed bearings are lubricated there is no need to lubricate them further Extra lubricant will cause more lint and dust buildup causing the bearings to prematurely fail Re...

Страница 27: ...move two 2 screws with 3 16 Allen Key to remove lower cast sur round set aside on a soft surface 4 Lift fan housing up off pins on floor of unit 5 Remove fan from unit 9 To install fan reverse Steps 8 1 6 Remove 3 screws to remove fan heat shield 7 Slide back the protect sheath on the wiring disconnect the black red and white wires 8 Disconnect the ground wire located on the left side of the fan h...

Страница 28: ...a cold stove close the door Try to remove the paper by pulling The paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Inspect condition and seal of Glass Gasket Door Gasket Perform paper test replace gasket if required Check and lubricate door hinge latch Use only high temperature anti seize lube ie never seize Check g...

Страница 29: ...rews set of 2 6 Screws 10 24 x 3 8 9 156 514 Door Handle Assembly 11 156 519 Door Catch 12 156 513 Door Assembly Metallic Black no glass 846 570 Med Density Door Gasket Kit 13 156 241 Cast Handle 14 074 954 Air Tube 1 Qty 1 15 033 953 Air Tube 3 4 Qty 1 16 073 955 Baffle 2 set 17 171 932 Standard Flue Adaptor 171 936 Offset Flue Adaptor 18 156 060N Draft plate arm 19 820 483 Stainless smoke deflec...

Страница 30: ...mbly 11 156 519 Door Catch 12 156 513 Door Assembly Metallic Black no glass 846 570 Med Density Door Gasket Kit 13 156 241 Cast Handle 14 074 954 Air Tube 1 Qty 1 15 033 953 Air Tube 3 4 Qty 1 16 073 955 Baffle 2 set 17 171 932 Standard Flue Adaptor 171 936 Offset Flue Adaptor 919 540 Manual Not available as a replacement part 1 2 12 19 5 11 18 20 13 9 18 910 140 3 way switch 19 910 157 P Fan Asse...

Страница 31: ... Not available as a replacement part FIREBRICK Part Description 156 960 Complete Brick Set 1 Brick Regular Full Size 1 1 4 x 4 1 2 x 9 2 Brick Partial 1 1 4 x 2 x 9 3 Brick Partial 1 1 4 x 1 1 4 x 9 4 Brick Partial 1 1 4 x 4 1 2 x 8 5 Brick Partial 1 1 4 x 4 1 4 x 8 6 Brick Partial 1 1 4 x 4 1 2 x 5 1 2 7 Brick Partial 1 1 4 x 3 x 4 1 2 Not available as a replacement part CI1250 Bottom Surround CI...

Страница 32: ...32 Regency CI1200 CI1250 Wood Cast Insert 32 notes ...

Страница 33: ...Regency CI1200 CI1250 Wood Cast Insert 33 33 notes ...

Страница 34: ...34 Regency CI1200 CI1250 Wood Cast Insert 34 notes ...

Страница 35: ...e warranty will be invalid Exclusions This limited Lifetime Warranty does not extend to or include paint door or glass gasketing firebrick back sides bottom or trim It does not cover installation and operational related problems such as over firing use of corrosive driftwood wood preservatives metal foils coal plastic garbage sulphur mill ends oils solvents petroleum products railroad ties paper car...

Страница 36: ...__________________ Serial No ___________________________________________________________ Printed in Canada Regency Alterra are trademarks of FPI Fireplace Products International Ltd Copyright 2015 FPI Fireplace Products International Ltd All rights reserved Register your Regency warranty online www regency fire com Reasons to register your product online today View and modify a list of all your re...

Отзывы: