CB72EPV Gas Fireplace
HORIZONTAL TERMINATIONS
RIGID PIPE 4" X 6
-5/8"
The minimum components required for a basic horizontal termination
are:
1 Power Vent Kit
1 Rigid Pipe Adaptor
1 Vent Reducer
1 Length of pipe to suit wall thickness and total vent run
(see Table 1)
Wall thickness is measured from the back standoffs to the inside mounting
surface of termination cap. Create a level surface to mount the vent
terminal. The Terminal must not be recessed into siding. Measure the
wall thickness.
Flat Wall Installation
Wall Thickness
(inches)
Vent Length Required
(inches)
4" - 5-1/2"
6"
7" - 8-1/2"
9"
10" - 11-1/2"
12"
9" - 14-1/2'
11" - 14-5/8" Adj. Pipe
15" - 23-1/2"
17" - 24" Adj. Pipe
Adj.Pipe Length
Rigid Pipe Adapter
o
90 Elbow
Pipe Length
Vent reducer
(Part #946-606)
Powervent Kit
(Part #946-535)
Table 1