![Regency Fireplace Products Bellavista B36XTE Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/regency-fireplace-products/bellavista-b36xte/bellavista-b36xte_owners-and-installation-manual_1433856005.webp)
Bellavista
®
B36XTE-11 Gas Fireplace | 5
safety decal
This is a copy of the label that accompanies each Bellavista™ B36XTE Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
Copy of Safety Decal
Decal Location
For the State of Massachusetts, installation
and repair must be done by a plumber or
gas fitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
501
501
DOOR SEAL: Please check
that the door is properly
sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Dégagements minimaux par rapport aux matériaux combustibles
Serial No./ No de série
919-999a
Electrical supply/Alimentation électrique 115VAC, 1.13 A, 60Hz.
NOT FOR USE WITH SOLID FUELS. / NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.
Made in Canada/ Fabriqué au Canada
Duplicate S/N
0" Clearance to
combustibles from /
Top, sides, bottom and rear of unit
Mantel Clearances from
Fireplace Opening /
(A) Min. 13" (330mm)
Side Wall Clearance
from Fireplace Opening /
B) Min. 12” (305mm)(on one side)
Ceiling from Top of
Fireplace Opening:
C) 36-3/4” (933mm)
Mantel Depth:
D) Max. 12” (304mm)
Alcove Clearances:
E) Min. Width 84" (2134mm),
F) Max. Depth 36" (914mm)
Minimum Vent Clearances:
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/2" (38mm)
(
See Instruction Manual for detailed instructions)
APPAREIL
FONCTIONNANT AU GAZ PROPANE
Modèle B36XTE-LP11
PROPANE GAS: Model B36XTE-LP11
NATURAL GAS: Model B36XTE-NG11
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
Pression d'alimentation minimale
Pression manifold - haute
Pression manifold - basse
Taille de l'orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
5.0" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
# 35 DMS
21,500 Btu/h (6.3 kW)
31,000 Btu/h (9.09 kW)
0-4500 ft/pi
(0-1372 m)
Part #: 919-999a
Colour: Everything black on grey except what is highlighted is printed red.
Size: File@100% 9.125’’W x 6.095’’H
Dec. 13/18 : Created Draft
Jan. 22/19: Rev A - Remodeled the decal and added ETL logo
*
Printer
:Start serial sequence @ 000001
Pression d'alimentation minimale
Pression manifold - haute
Pression manifold - basse
Taille de l'orifice
D bit calorifique minimal
é
D bit calorifique maximal
é
Altitude
11" WC/C.E. (2.74 kPa)
10" WC/C.E. (2..49 kPa)
6.4" WC/C.E. (1.60 kPa)
# 51 DMS
25,000 Btu/h (7.33 kW)
31,000 Btu/h (9.09 kW)
0-4500 ft/pi
(0-1372 m)
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in
the United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See
owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit #578-972). Fan Part # 578-917.
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur. Installer l'appareil
selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces normes
ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à
demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée
est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY POUR UTILISATION UNIQUEMENT AVEC LES PORTES EN VERRE CERTIFIÉES AVEC L'APPAREIL
For Use Only with Barrier (Part #578-005 with Vignette) or (Part #578-929 Installed with Flush Panels) Follow installation instructions.
Utiliser uniquement avec l’écran ( n°578-005 avec façade Vignette) ou ( n°578-929 Installation avec panneaux affleurants). Suivre les consignes d'installation.
E
B
A
C
D
F
C #: 4001172
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Listed/Nom:
VENTED GAS FIREPLACE / FOYER AU GAZ À ÉVACUATION
Certified to/Certifi pour:
é
ANSI Z21.88-2017 • CSA-2.33-2017
CSA 2.17-2017
Refer to Intertek's Directory of Building Products for detailed information.
Pour plus de détails , se reporter au Répertoire des produits de construction de Intertek.
APPAREIL
FONCTIONNANT AU GAZ NATUREL
Modèle B36XTE-NG11
CSA P.4.1 Fireplace Efficiency (FE) /Efficacité énergétique des foyers (EEF) CSA P.4.1
Natural Gas / Gaz naturel 65.90%
Propane Gas / Gaz propane 65.90%
CANADIAN ENERGY
PERFORMANCE
VERIFIED
RENDEMENT
ÉNERGÉTIQUE
VÉRIFIÉ
EP5011169
Remove the faceplate from unit (refer to
manual) the rating plate will be attached
to a black chain as shown below.
DO NOT REMOVE DECAL FROM UNIT.