Bellavista® B36XTE-10 Gas Fireplace
|
38
installation
Pipe Length
Vertical
Termination
Cap
Storm Collar
Flashing
Ceiling Firestop
Rigid Pipe Adaptor
Pipe
Length
Pipe Length
90 Elbow
o
Astrocap
(946-523/P)
Wall Thimble
Vinyl Siding
Standoff (Optional)
Reducer
(4” x 6-5/8” venting)
43”
(1092 mm)
HORIZONTAL OR VERTICAL TERMINATIONS
RIGID PIPE 4" X 6-5/8"
(MUST USE REDUCER PART # 946-606 & 770-994 RIGID PIPE ADAPTOR)
The minimum components required for a basic horizontal termination using 4" x 6-5/8" are:
1 Rigid Pipe Adaptor (770-994)
1 Reducer (946-606)
1 90
o
Elbow
1 Wall Thimble
1 Length of pipe to suit wall thickness
1 Horizontal Termination Cap
Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap. For siding other than vinyl furring strips
may be used, instead of the vinyl siding standoff, to create a level surface to mount the vent terminal. The Terminal must not be recessed into
siding. Measure the wall thickness including furring strips.
If a Vinyl Siding Standoff is required (it must be used with vinyl siding), measure to outside surface of wall without siding and add 2 inches.
A
B
11”
(279mm)
11”
(279mm)
ASTROCAP # 946-523/P
DIMENSIONS
This product has been evaluated by Intertek
when using a rigid pipe adaptor and use of
any of the specific chimney systems listed in
this manual. Use of these systems with the
rigid pipe adaptor is deemed acceptable and
does not affect the Intertek WHI listing of these
components.
WARNING:
Do not combine venting components from
different venting systems.
However use of the the AstroCap
TM
and
Regency Riser is acceptable with all systems.
The Regency AstroCap
TM
and Regency Riser Vent terminal are certified for installations using Regency venting systems as well as any specific
chimney systems listed in this manual. AstroCap
TM
is a proprietary trademark of Regency Fireplace Products.