background image

Bellavista® B36XTE 

Gas Fireplace

Owners & 

Installation Manual

www.regency-fire.com

Tested by:

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

MODEL: B36XTE-10  

Medium DV Gas Fireplace

Bellavista B36XT Video

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach your gas supplier, call the fire department.

 

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

919-390e

    FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

08.20.18

Содержание Bellavista B36XTE-10

Страница 1: ...U SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the...

Страница 2: ...warmth and charm of a wood fireplace at the flick of a switch The Bellavista B36XTE has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fir...

Страница 3: ...and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This appliance comes equipped with a dedicated 8 Ground Lug for attachment of the ground wire to the steel chassis...

Страница 4: ...wo 2 90o Elbows Rigid Pipe 4 x 6 5 8 39 Horizontal terminations 39 Three 3 90o Elbows Rigid Pipe 4 x 6 5 8 39 venting arrangements For Vertical Terminations 40 Rigid pipe 4 x 6 5 8 40 Vertical terminations 41 Three 3 90o Elbows Rigid Pipe 4 x 6 5 8 41 venting arrangements 42 With Co linear Flex System 42 Vertical Terminations 43 Co linear Flex System Into Masonry Fireplaces 43 Unit Installation wi...

Страница 5: ...ation minimum Pression à la tubulure d chappement lev e é é é Pression à la tubulure d chappement basse é Grandeur de l injecteur D bit Calorifique minimum selon é D bit Calorifique maximum selon é l altitude 11 WC C E 2 74kPa 10 WC C E 2 49kPa 6 4 WC C E 1 60kPa 51 DMS 25 000 Btu h 7 33kW 31 000 Btu h 9 09kW 0 4500 ft pi 0 1372m Minimum supply pressure Manifold pressure high Manifold pressure low...

Страница 6: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 7: ...m 838mm 40 3 8 463 5mm Front view shown with 3 sided finishing trim 37 3 4 34 5 8 35 5 16 1 7 8 22 5 16 11 16 959mm 567mm 897mm 879mm 48mm 18mm 3 Sided Vignette Trim 4 Sided Vignette Trim Vignette Finishing Trim ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Страница 8: ...8 Bellavista B36XTE 10 Gas Fireplace 8 dimensions UNIT DIMENSIONS WITH OPTIONAL FLUSH PANELS AND SAFETY SCREEN 3 sided finishing trim not shown 40 1 2 wide x 35 3 4 high ...

Страница 9: ...pliance requirescommonsense however wearerequired by the Canadian Safety Standards and ANSI Standards to make you aware of the following GENERAL SAFETY INFORMATION 1 The appliance installation must conform with local codes or in the absence of local codes with the current Canadian or National Gas Codes CAN1 B149orANSIZ223 1Installation Codes 2 The appliance when installed must be electrically grou...

Страница 10: ...on e VentingRequirements Referto Venting section 2 Assemble Top Standoffs and Top Facing Support and Side Nailing Strips Refer to Unit AssemblyPriortoInstallation Section NOTE Must be done before installing unit into place 3 Install vent Refer to Venting sections 4 Makegasconnections Testthepilot Mustbe as per Diagram Refer to Pilot Adjustment section Convert to propane if desired Refer to Gas Lin...

Страница 11: ...ce that this fireplace and vent system be installed only in accordance with these instructions B36XTE Clearance Requirements Minimum Vent Clearances to Combustibles Clearance Dimension Measured From A Mantel Height min with Vignette Vignette Trim Stepped finish 13 330mm Top of Fireplace Opening A Mantel Height min with Flush Panels and Safety Screen 13 330mm Top of Fireplace Opening A Mantel Heigh...

Страница 12: ...t this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of unit are shown in the diagram below Note Mantel starts at 1 deep and ends at 12 deep For Vignette with Vignette Finishing Trim flush finish all materials framing finishing below the mantel and the width of the Vignette finishing trim 37 3 4 must be non combustible if a lower mantel is desired Note E...

Страница 13: ...own to secure the non combustible material Diagram 1 Diagram 2 Vignette Vignette Finishing Trim Flush Finished Vignette Vignette Trim stepped finish or with Flush Panels and Safety Screen 1 Determine the total thickness of facing material e g non combustible plus ceramic tiles to allow the finished surface to be flush with the front of the unit Total facing thickness can vary from 1 2 13mm to 1 1 ...

Страница 14: ...s Q Top Vent Corner Facing Wall Width 68 3 4 1746mm Q Rear Vent Corner Facing Wall Width 75 1905mm AstroCapXL 87 2209mm other approved caps R Rear Vent Framed Chase Ceiling Rear 42 1067mm R Top Vent Framed Chase Ceiling Top 50 1 2 1283mm S Rear Vent Vent Centerline Height Rear 26 1 2 673mm S Top Vent 5 x 8 Vent Centerline Height Top 42 1 8 1070mm Flex 44 1 4 1123mm Rigid S Top Vent 4 x 6 5 8 Vent ...

Страница 15: ... approved caps R Rear Vent Framed Chase Ceiling Rear 42 1067mm R Top Vent Framed Chase Ceiling Top 50 1 2 1283mm S Rear Vent Vent Centerline Height Rear 26 1 2 673mm S Top Vent 5 x 8 Vent Centerline Height Top 42 1 8 1070mm Flex 44 1 4 1123mm Rigid S Top Vent 4 x 6 5 8 Vent Centerline Height Top 49 1245mm Rigid T Gas Connection Height 1 1 2 38mm U Gas Connection Inset 4 1 8 105mm V Gas Connection ...

Страница 16: ...a B36XTE 10 Gas Fireplace 16 installation NON COMBUSTIBLE REQUIREMENTS Diagram 1 Diagram 2 Vignette Vignette Finishing Trim Flush Finish Vignette Vignette Trim Stepped Finish or with Flush Panels and Safety Screen ...

Страница 17: ...on box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Receiver...

Страница 18: ...louvers or flush panels if not using the optional finishing trim To maintain a clean finished edge it is recommended to install the non combustible facing material with the finished edge against the fireplace nailing strips Alternatively you can use J Style Trim or Metal Corner Bead to cover cut edges of the non combustible facing material UNIT ASSEMBLY PRIOR TO INSTALLATION BEFORE YOU START The T...

Страница 19: ...depth of 1 1 4 32mm the top facing support must be reversed Side Nailing Strip eps Nail4 eps Nail5 eps A A B C B C Top Facing Support is reversed for C hole position A A B C B C Screw holes for Side Nailing Strip Top Facing Support Nail6 eps A B C Screw holes for Top Facing Support Top Facing Support is reversed for C hole position A B C Top Facing Support SIDE NAILING STRIPS The side nailing stri...

Страница 20: ...y Gasket spare 1 Insulation Plate Cover 1 Insulation Filling Exhaust Assembly w gasket Intake Cover Plate w gasket Insulation cover plate Insulation filling Intake Collar Assembly w gasket 2 From inside the firebox remove the top heat deflector by removing 2 screws Heat Deflector Diagram 2 1 Remove the door assembly by releasing the adjustable latches and lifting up off the door frame assembly Adj...

Страница 21: ... tight but do not over tighten All 8 screws must be used Diagram 8 Diagram 9 10 From the outside rear of the firebox install the intake cover plate with 4 1 4 x 1 2 screws Ensure all screws are tight but do not over tighten All 4 screws must be used 11 Set vent restrictor accordingly see next page 12 From inside the firebox re install the baffle plate and heat deflector reverse steps 2 3 9 From th...

Страница 22: ... a vent restrictor setting is required Note The vent restrictor does not apply to rear vent applications 4 Align the vent restrictor plate to the required vent restrictor position as per the Diagrams shown 5 Once the vent restrictor plate is in the required position secure with 2 1 4 x 1 2 screws Ensure all screws are tight but do not over tighten See Diagram 2 VENTING INTRODUCTION The B36XTE uses...

Страница 23: ...tended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on publi...

Страница 24: ... vent collar Slide the outer adapter over the collar and secure with 3 screws Inner adaptor Outer adaptor Inner collar Outer collar Millpack Millpack B36XTE B36XTCE B36XTE B36XTCE tooltip tooltip 1 Apply a bead of Millpack around the base of the inner vent collar Slide the inner adapter over the collar and secure with 3 screws 3 Follow installation instructions for the Flex venting kit 2 Apply a b...

Страница 25: ...eded to install the B36XTE with a maximum run of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 A...

Страница 26: ...T KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it reaches the flashing 1...

Страница 27: ...iagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling firestop A ceiling firestop firestop spacer must be installed when passing through each floor or ceiling level To install the...

Страница 28: ...ngth 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galvanized 4...

Страница 29: ...A 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 P Vent Guard Optional for Ris...

Страница 30: ...all Support Band 58DVA WS 5DT WS B 5DWS TM 5WS VDV WS05 Offset Support 58DVA ES N A from FPI 5DT OS N A TM 5OS N A Wall Thimble Black 58DVA WT 5DT WT 5DWT N A VDV WPT05 Wall Thimble Support Ceiling Support 58DVA DC N A from FPI N A N A N A N A Firestop Spacer 58DVA FS 5DT FS 5DFS TM 5LS VDV FS05 Trim Plate Black 58DAV WFS 5DT TP 5DCP TM 5TP VDV WTC05 5 X 8 RIGID PIPE CROSS REFERENCE CHART Componen...

Страница 31: ...Horizontal Cap 770 994 Rigid Pipe Adaptor Must use with all rigid piping 946 506 P Vent Guard Optional 946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 B36XTE B36XTCE ONLY 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 5DDA must be used in conjunction with FPI Rigid Pipe Adaptor 770 994 Not available applicable for the follo...

Страница 32: ... AstroCap XL 946 623 P 1 Rigid Pipe Adaptor 770 994 1 Vinyl Siding Standoff Optional 946 625 1 Wall Thimble 58DVA WT 1 6 galvanized rigid pipe 58DVA 06 1 8 1 2 galvanized pipe extension 58DVA 08A 1 45º galvanized elbow 58DVA E45 1 90 ml MillPac 948 128 26 1 2 673mm Placement of the unit into the corner Back top corner of unit to wall 4 Inside corner out along the wall 53 Across the face of the uni...

Страница 33: ...termination in a corner installation Kit 946 612 Includes 1 AstroCap XL 946 623 P 1 Rigid Pipe Adaptor 770 994 1 Vinyl Siding Standoff Optional 946 625 1 Wall Thimble 58DVA WT 1 6 galvanized rigid pipe 58DVA 06 1 8 1 2 galvanized pipe extension 58DVA 08A 1 45º galvanized elbow 58DVA E45 1 90 ml MillPac 948 128 26 1 2 673mm Placement of the unit into the corner Back top corner of unit to wall 4 Ins...

Страница 34: ...ions with a maximum continuous vent maximum horizontal length of 3ft 0 9m Note Must use optional rigid pipe adaptor Part 770 994 when using Rigid Pipe vent systems Maintain clearance to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall 2 0 12 6 4 8 10 2 0 6 4 8 Vertical Height Feet Rigid 44 1 4 1 1m Horizontal...

Страница 35: ...d if venting to the minimum of 42 1 8 to centerline No other application is approved 1 8 dia flexible liner 4 ft length 2 5 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 5 AstroCapXL termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 10 vinyl siding standoff Notes 1 Liner sections should be continuous without any join...

Страница 36: ...th Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff Optional Horizontal Termination A Top Vent No Vertical Rise When venting with a 90 elbow directly off the unit must use 5 X 8 AstroCapXL Flex vent or approved Rigid Vent System Max 3 ft horizontal run B Rear Vent w Horizontal Termination Can only use 5 x 8 venting Max 3ft horizontal run B A HORIZONTAL TERMINATIONS RIGID PIPE 5 X 8 ...

Страница 37: ...R PART 946 606 770 994 RIGID PIPE ADAPTOR The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Maintainclearancestocombustiblesaslistedin Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A wall thimble is mandatory fo...

Страница 38: ...o create a level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be used with vinyl siding measure to outside surface of wall without siding and add 2 inches A B 11 279mm 11 279mm ASTROCAP 946 523 P DIMENSIONS This product has been evaluated by Intertek when using a r...

Страница 39: ...ucer 946 606 and rigid pipe adaptor 770 994 No Vent Restrictor Installed HORIZONTAL TERMINATIONS THREE 3 90O ELBOWS RIGID PIPE 4 X 6 5 8 V1 H1 H V Lengths do not include elbow indicated Must use reducer 946 606 and rigid pipe adaptor 770 994 Option V H V V1 H H1 A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 Min 4 Max D 3 Min 2 Max 7 Min 5 Max E 4 Min 3 Max 9 Min 6 Max F 5 Min...

Страница 40: ...ach floor level and whenever passing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting to 2 1 4 opening 1 5 8 opening and to 1 1 16 opening Note Must use optional flue adapter when using Rigid Pipe Part 770 994 Maximum 35 5 ft 10 m 8 Minimum 8...

Страница 41: ...Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required One 90o elbow Two 45o elbows Lengths do not include elbow indicated Must use reducer 946 606 and rigid pipe adaptor 770 994 No Vent Rest...

Страница 42: ...d Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 35 ft 946 563 Co Axial to Co Linear Adapter Kit whichcontainsthefollowing Co linear Flex Adapter Outer Pipe Inner Pipe Adapter 770 994 Rigid Pipe Adaptor 946 606 Vent Reducer Alternate Approved Caps 46dva VC Vertical Termination Cap 46dva VCH High Wind Cap 46dva GK 3 Co linear Adapter with flashing Flex Liner Exh...

Страница 43: ...E 10 Gas Fireplace 43 43 installation VERTICAL TERMINATIONS CO LINEAR FLEX SYSTEM INTO MASONRY FIREPLACES FOR BOTH RESIDENTIAL MANUFACTURED HOMES The shaded area in the Diagrams show the allowable vertical terminations ...

Страница 44: ...thefireplaceandfastenittotheframing using nails or screws through the top and side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failuretodosomayresult in drafting or performance issues not covered under warranty Diagram 2 Horizontal runs of vent mus...

Страница 45: ... Separatethe2halvesofthewallthimbleand securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom Fasten the other thimble half to the inside wall The thimble halves slip inside each other and can be adjusted for 2 x 4 or 2 x 6 walls 5 Slip the assembled liner and termination assembly through the thimble making sure the termination cap faces up there ...

Страница 46: ... every level To install the Firestop spacer in a flat ceiling or wall cut a 10 inch square hole Frame the hole as shown in Diagram 2 and install the firestop 4 Assemble the desired lengths of pipe and NOTE For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Failure to do so may result ...

Страница 47: ...Screw should be snug but do not over tighten B36XTE NG10 System Data Conversion Kit 576 969 For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 35 Max Input Rating 31 000 Btu h Min Input Rating 21 500 Btu h Supply Pressure min 5 0 w c Manifold Pressure High 3 5 0 2 w c Manifold Pressure Low 1 6 0 2 w c B36XTE LP10 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 51 Max Input R...

Страница 48: ...per Motor 1 919 437 Instruction Sheet Installation of LP Conversion Kit 10 Re install pilot cap wire clip and pilot shield 11 Remove burner orifice with a 1 2 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice 12 Reinstall new burner orifice LPG stamped 51 and tighten 7 Remove the wire clip below the pilot cap 9 Unscrew the pilot orifice with the allen key then re...

Страница 49: ...ring the burner assembly and rear log tray so the panel is not damaged Note Ensure that an equal space gap is maintained on both the right and left side when installing the back panel 5 Remove the hex head screw on the upper left side of the firebox wall Position left brick panel in place and secure with the brick panel clip and screw 6 Slide top brick panel under left and back brick panel use car...

Страница 50: ...unit Failure to do this will result in burn stains on panels which you will be unable to remove Not protected by product warranty 5 Repeat step 4 for left side panel 6 Reverse step 1 Final Installation 4 Remove 1 screw see inset A position right side panel in firebox position panel clip in place and secure with 1 screw see inset B Tighten the screw A B 1 Remove the heat deflector by removing the 2...

Страница 51: ... Top Middle Log D Top Right Log E Rear Log 902 156 Lava Rocks 902 179 Vermiculite 946 669 Platinum Embers supplied w packaged manual 1 Carefully remove the logs from the packaging and unwrap them The logs are fragile handle with care do not force into position 2 Spread vermiculite along the base of the firebox Vermiculite D E A C B 4 Place Log B on the front left side of the burner Position the no...

Страница 52: ...the front right side of the burner Position the notch on the bottom right side of the log into the right side of the grate Slide Log A back towards Log E until the flat surface on Log A rests up against the tabs on the burner and grate this maintains a necessary gap between Logs A E Note Use the notch on the bottom of Log A as a guide see below Tabs on burner grate Back of Log A A 7 The notch on t...

Страница 53: ...und the lava rocks Avoid stacking platinum embers Platinum embers may be placed over burner ports 9 Position Log C with the flat side toward Log E Fit Log C onto left peg on Log E the notch on the bottom of Log C rests against the 3rd from the left grate post 10 Test fire to ensure proper light off make sure flame flows smoothly from one end of the burner to the other If there is any flame hesitat...

Страница 54: ... dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges Proflame System Configuration 886 GTMF Wire Diagram SureFire Switch 885 1 of 10 AC Adaptor WIRING DIAGRAM This heater does not require a 120V A C supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries In case of a power fai...

Страница 55: ...e fan motor Slide the black wire and the green ground wire into grommet and push grommet into the fan assembly housing 5 Connect the White wire onto the right side terminal of the fan motor Connect the red wire into the grommet and push grommet into the fan assembly housing BLACK WHITE 6 Position the fan base with the motor end towards the rear of the firebox and then slide the fan in towards the ...

Страница 56: ...e bracket clip on the left underside of the firebox Ensure that no wires will touch hot surfaces 11 Plug in the fan power cord to the Fan Control Module into the outlet marked Fan Plug the FCM COM wire from the remote control wiring harness into the location on the Fan Control Module marked COM Turn the switch on the Fan Control Module to the ON posi tion ON is to the left The O is the off positio...

Страница 57: ...WIRING DIAGRAM WITH OPTIONAL FAN SureFire Switch CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges ...

Страница 58: ...ill be located near the gas valve Disconnect greenTH wire Green Wires White Connector 3 Connect one thermostat lead to female connector using male spade con nector see picture below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step 1 using a female spade connector see picture below When complete turn remote receiver to th...

Страница 59: ...he 2 screws securing the cover plate to the firebox base Discard cover plate keep the 2 screws 6 From inside the firebox feed the wires from the bottom of the light assembly through the opening exposed after the removal of the cover plate 7 When light assembly has been fully seated secure in place with 2 screws that were removed from the cover plate 8 From underneath the firebox slide back the pro...

Страница 60: ...g to the base of the unit Ensure wiring does not come into contact with the fan blades or any sharp metal edges Wire Clip Gasket Ground Lug 15 Install a gasket over top of the bulb Installed diffuser shown below with 2 options a With amber glass plate for use with units without panels or with brick panels Left and right side tabs to be bent down 90 degrees as shown below Image A b Amber glass plat...

Страница 61: ...eptacle located on the bottom left side of the unit 20 Turn on electrical supply test lights 1 Follow steps 1 4 from previous page 2 Remove 2 screws to remove light diffuser plus gasket 3 Replace thebulb donottouchbulbwithbarehands useglovesorbulb packaging to protect bulb 4 Reinstall the gasket and light diffuser 5 Reverse steps 4 1 Ground Wire Receptacle BULB REPLACEMENT ...

Страница 62: ... by AC adaptor Break Tab on Black hot side Ground Ground Copper Black Hot White Neutral Do not break Tab on White neutral side Clamp Connector Receptacle located inside the unit Supplied with the appliance NOTE ON OFF switch all wires supplied by others Scheme 2 Only Use if Optional Fan is purchased Green Optional Accent Light Receptacle located inside the unit Extension Cord NOTE Lights can be tu...

Страница 63: ...th tabs in firebox Hook slots on to tabs and lower door slowly See Diagram 1 2 Lower the flush door then hook the 2 adjustable tension latches close the latches to secure the flush door See Diagram 2 Diagram 1 Tabs in Firebox Diagram 2 Adjustable Tension Latch location Note To remove Flush Glass door reverse Steps 1 and 2 ...

Страница 64: ...s on mesh assembly with slots in outer frame and lower gen tly into place Bring bottom of the mesh assembly toward the front of the appliance until it comes in contact with the magnets 3 To remove reverse steps Black Chrome Handling Instructions All hand and finger marks MUST be cleaned off with a soft cloth Use an ammonia based cleaner ie glass cleaner to remove any finger prints before applying ...

Страница 65: ...ion the Inlay so it is exactly centered from side to side and top to bottom within the Inner Vignette Frame 4 With the top of the Inlay in correct position push the studs at the bottom of the Inlay through the actual screen NOTE Ensure Inlay is in correct position before pushing studs through the safety screen 5 Secure the Inlay in position with supplied brackets washers and nuts as shown Bracket ...

Страница 66: ...im Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure 5 Hook Vignette Faceplate brackets into place 6 Line up the screw holes on the finishing trim and Vignette Face plate bracket with the unit fasten with 2 screws on each side 8 Hook Vignette Faceplate brackets into place see specific instructions in unit manual 7 Install the lower finish...

Страница 67: ...sh Panels 2 Line up the tabs on Flush Panels with the brackets on the unit 3 Hook the tabs up over the brackets to attach 4 Install Top Panel first as clearance is restricted once safety screen is in place Tabs on Flush Panel Bracket on unit for upper Flush Panel Completed Install shown with screen Bracket on unit for lower Flush Panel Installation of upper Flush Panel Installation of lower Flush ...

Страница 68: ...RIM INSTALLATION SAFETY SCREEN INSTALLATION MUST BE USED WITH PREMIUM FLUSH FRONT 919 590 919 590 07 23 15 07 23 15 B36XTE B36XTE SAFETY SCREEN INSTALLATION MUST BE USED WITH OPTIONAL PREMIUM FRONT 1 Hook the safety screen frame onto brackets within the unit in locations shown below 2 Gently lower screen on to glass door frame two 2 magnets located on inside lower part of the screen frame will sec...

Страница 69: ...tion and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE FIRST FIRE NORMAL OPERATING SOUNDS OF GAS APPLIANCES It is possible that you will hear some sounds from yourgasappliance Thisisperfectlynormaldueto the fact that there are various ga...

Страница 70: ...nds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if using opt...

Страница 71: ...service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l inform...

Страница 72: ... Glass Door Removal section MAINTENANCE INSTRUCTIONS 1 Always turn off the gas valve before cleaning Forrelighting refertolightinginstructions Keep the burner and control compartment clean by brushing and vacuuming at least once a year When cleaning the logs use a soft clean paint brush as the logs are fragile and easily damaged 2 Clean appliance and door with a damp cloth never when unit is hot N...

Страница 73: ...EV2 and ground wires from the valve as shown below Diagram 3 Diagram 5 Diagram 8 Diagram 6 INSTALLING VALVE 1 Place new valve tray into position 2 Reinstall the 8 hold down screws 3 Hook up the 2 TP and 2 TH wires to the ap propriate connections on the valve 4 Reinstall the rear log tray 5 Install burner grate assembly 6 Hook up the gas line and check for gas leaks with a soap and water solution o...

Страница 74: ...op 9 576 901 Brick Panel Standard Brown 576 902 Brick Panel Standard Red 576 904 Brick Panel Castle Stone 576 908 Black Enamel Panels 10 820 389 Thermodisc Bracket 12 948 165 Adjustable Tension Latch 13 904 731 Capscrew 1 4 20 x 3 5 NC Gr5 14 940 357 P Ceramic Glass 15 556 012 Door Frame 16 Outerbox Assembly 17 Firebox Assembly Part Description 18 578 917 Fan Assembly 19 910 215 P Fan Motor 120 Vo...

Страница 75: ...Bellavista B36XTE 10 Gas Fireplace 75 75 parts list MAIN ASSEMBLY 23 FAN SWITCH ASSEMBLY 22 20 21 3 4 5 6 13 7 8 16 17 14 12 10 11 18 9 15 19 1 2 25 26 ...

Страница 76: ...sembly NG 578 576E P Valve Assembly LP 10 911 006 Pilot Assembly NG 911 007 Pilot Assembly LP Part Description 911 012 Ignition Board DBC 911 013 Wiring Harness Switch 911 018 Battery Holder 911 037 Flame Sensor 911 038 Flame Electrode 911 039 Pilot Hood 910 432 Pilot Tube 911 228 P Remote Recevier 910 592 Remote Control GTMF hand held 911 030 Fan Control Module 910 100 Pilot Orifice NG 910 101 Pi...

Страница 77: ... Fireplace 77 77 parts list OPTIONAL ACCESORIES Part Description 1 576 916 Flush Panels 2 578 929 Safety Screen 3 578 928 Vignette Trim 4 578 918 Vignette Inlay Chrome 578 919 Vignette Inlay Black 578 920 Vignette Inlay Sunset ...

Страница 78: ...ttery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any p...

Страница 79: ...wndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the...

Страница 80: ...al codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and tel...

Страница 81: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ma...

Страница 82: ......

Страница 83: ......

Страница 84: ...e the following information Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No _________________...