Regency Albany Freestanding Wood Fire

maintenance

Pull - Open

WARNING:  To build a fire in ignorance 

or to disregard the information con-

tained in this section can cause serious 

permanent damage to the unit and void 

your warranty!!

AIR SLIDE CONTROL

Both the primary and air wash drafts are control-

led by the control rod located on the right side 

of the unit (when facing the unit). To increase 

your draft - pull open, and to decrease - push 

closed.  All units have a secondary draft system 

that continually allows combustion air to the 

induction  ports  at  the  top  of  the  firebox,  just 

below the flue baffle.  

3 SPEED 
FAN OPERATION

A 3 speed fan is fitted to the heater. The fan is con

-

trolled by a thermodisc, and Auto / Manual switch 

and a speed selection switch. The Auto / Manual 

switch is mounted on the back of the pedestal. The 

speed select switch is located on the right hand side 

of the pedestal and has selections for fan  OFF/ 

LOW / MED /HI. The OFF position is marked by a 

red dot on the pedestal.

Manual control of the fan

Select Manual control and the fan speed will be 

directly controlled by the selection of the fan speed 

switch.

Automatic Control of the fan

Select Auto control of the fan and the fan will be 

controlled by the selection on the fan speed switch 

and the temperature of the heater. The thermodisc  

in the fan circuit ensures that the heater has achieved 

a high temperature before the fan can operate– this 

may take 20-30 minutes. When the heater cools 

down the fan will automatically turn off–this may 

take 20-30 minutes.

Selection OFF on the fan speed switch will always 

turn the fan off immediately.

OPERATING 
INSTRUCTIONS

With your unit now correctly installed and safety 

inspected by your local authority, you are now 

ready to start a fire.  Before establishing your 

first fire, it is important that you fully understand 

the operation of your draft control.

CAUTION: THIS APPLIANCE MUST BE 

MAINTAINED AND OPERATED AT ALL TIMES 

IN ACCORDANCE WITH THESE INSTRUC-

TIONS.

CAUTION: THE USE OF SOME TYPES OF 

PRESERVATIVE-TREATED WOOD AS A FUEL 

CAN BE HAZARDOUS.

WARNING: ANY MODIFICATION OF THE AP-

PLIANCE THAT HAS NOT BEEN APPROVED 

IN WRITING BY THE TESTING AUTHORITY 

IS CONSIDERED AS BREACHING AS/NZS 

4013.

WARNING: DO NOT USE FLAMMABLE 

LIQUIDS OR AEROSOLS TO START OR 

REKINDLE THE FIRE.

WARNING: DO NOT USE FLAMMABLE LIQ-

UIDS OR AEROSOLS IN THE VICINITY OF 

THIS APPLIANCE WHEN IT IS OPERATING.

WARNING: DO NOT STORE FUEL WITHIN 

HEATER INSTALLATION CLEARANCES.

WARNING: OPEN AIR CONTROL (AND 

DAMPER WHEN FITTED) BEFORE OPENING 

FIRING DOOR.

FIRST FIRE

When your installation is completed and inspected 

you are ready for your first fire.

1)

  Open control fully.

2)

  Open firebox door and build a small fire using 

paper and dry kindling on the firebox base.  Se

-

cure door on the firebox and wait a few minutes 

for a good updraft in the flue to establish the 

fire.  (Leaving the door slightly open will help 

your fire start more rapidly.)

 

CAUTION:  Never leave unit unattended if 

door is left open.  This procedure is for fire 

start-up only, as unit may overheat if door 

is left open for too long.

3)

  With the draft still in the fully open position add 

two or three seasoned logs to your  fire. Form 

a trench in the ash bed to allow air to reach the 

rear of the firebox prior to closing the door.

4)

  After about 45 minutes, when your wood has 

begun to burn strongly, adjust your draft control 

down to keep the fire at a moderate level.

 

WARNING:  Never build a roaring fire in a 

cold heater.  Always warm your heater up 

slowly!

5)

  Once a bed of coals has been established on 

the base of the firebox, you may adjust the draft 

control to a low setting to operate the unit at its 

most efficient mode.

Push - Closed

For safety reasons and in order to avoid 

over firing of your unit do not burn your 

fire with the door open or ajar.

Содержание Albany F200B-2

Страница 1: ...tance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency Model F200B 2 Albany F200B 2 Freestanding Wood Fire FPI FIREPLACE PRODUCTS AUSTRALIA ...

Страница 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Страница 3: ...allation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 3 speed fan operation 8 MAINTENANCE Maintenance 9 Creosote 9 Ways to Prevent Keep Units Free of Creosote 9 Glass Maintenance 9 Door Latch Adjustment 9 Wood Storage 9 3 speed fan wiring diagram 10 PARTS LIST Heater Assembly 11 WARRANTY Warranty 14 ...

Страница 4: ...opy of the label that accompanies each F200B 2 Freestanding Wood Fire We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Albany Freestanding Wood Fire 5 DIMENSIONS dimensions ...

Страница 6: ...tivity Regency recommends that your unit is secured to the floor by using the bolt down holes inside the pedestal 11 Do not connect this unit to a flue serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater whi...

Страница 7: ...8m2 k w for 4mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Hawkwind Standard flue kit requires one 130o x 900mm stainless reflective shield between the decromesh casing and ac tive flue 2 The AHD Special Insulated flu...

Страница 8: ...tant that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERVATIVE TREATEDWOODASAFUEL CAN BE HAZARDOUS WARNING ANY MODIFICATION OF THE AP PLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARN...

Страница 9: ...ut 10 15 minutes every morning during burning season 2 Burn heater with draft control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system 3 Only burn seasoned wood Avoid burning wet or green wood Seasoned wood has been dried at least one...

Страница 10: ...10 Regency Albany Freestanding Wood Fire maintenance Note Thermodisc temp switch in the fan control circuit Heater Thermodisc must come up to operating temperature for fan to operate See page 8 ...

Страница 11: ...mbly 12 8010609 Ash Lip Panel 13 6150223 Fan Assembly fan only 14 1141400 Metal lip inside firebox 15 8010115 Glass Retainer Bracket 16 3720101 Door rope seal 5 ft 17 1141004 Rear Baffle Brick Support Bar 18 1211500 Latch Bracket 19 8010614 Hinge Bracket 20 1211201 Inner Back Shield 21 1151700B Air Slide Fasteners 3 pcs 22 8010611 Steel baffie 23 7510206 Cast Plate Set 24 1141704B Friebrick Retain...

Страница 12: ...12 Regency Albany Freestanding Wood Fire NOTES notes ...

Страница 13: ...Regency Albany Freestanding Wood Fire 13 NOTES notes ...

Страница 14: ...harges will apply It is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products wil...

Страница 15: ...d Aber Holdings 28 30 Division St 1 3 Conquest Way 17 Mainstreet Place Welshpool WA 6106 Hallam VIC 3803 Te Rapa Ha 3200 08 9350 2200 03 9799 7277 07 849 7585 NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Страница 16: ..._____________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and...

Отзывы: