background image

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

 

Manual

Aug-24-2016

918-795d

WARNING:  

Improper installation, adjustment, alteration, service or maintenance can 

cause injury or property damage. Refer to this manual. For assistance or 

additional information consult an authorised installer, service agency or 

the distributor.

FOR YOUR SAFETY

Do not store or use petrol or other flammable vapours and liquids in the 

vicinity of this or any other appliance.

Installation and service must be performed by an authorised installer or 

service agency.

Model:  F200B-2

Albany F200B-2 Freestanding Wood Fire

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1 CONQUEST WAY, HALLAM, VICTORIA 3803

Содержание Albany F200B-2

Страница 1: ...tance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency Model F200B 2 Albany F200B 2 Freestanding Wood Fire FPI FIREPLACE PRODUCTS AUSTRALIA ...

Страница 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Страница 3: ...allation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 3 speed fan operation 8 MAINTENANCE Maintenance 9 Creosote 9 Ways to Prevent Keep Units Free of Creosote 9 Glass Maintenance 9 Door Latch Adjustment 9 Wood Storage 9 3 speed fan wiring diagram 10 PARTS LIST Heater Assembly 11 WARRANTY Warranty 14 ...

Страница 4: ...opy of the label that accompanies each F200B 2 Freestanding Wood Fire We have printed a copy of the contents here for your review NOTE Regency units are constantly being improved Check the label on the unit and if there is a difference the label on the unit is the correct one ...

Страница 5: ...Regency Albany Freestanding Wood Fire 5 DIMENSIONS dimensions ...

Страница 6: ...tivity Regency recommends that your unit is secured to the floor by using the bolt down holes inside the pedestal 11 Do not connect this unit to a flue serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater whi...

Страница 7: ...8m2 k w for 4mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Hawkwind Standard flue kit requires one 130o x 900mm stainless reflective shield between the decromesh casing and ac tive flue 2 The AHD Special Insulated flu...

Страница 8: ...tant that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THESE INSTRUC TIONS CAUTION THE USE OF SOME TYPES OF PRESERVATIVE TREATEDWOODASAFUEL CAN BE HAZARDOUS WARNING ANY MODIFICATION OF THE AP PLIANCE THAT HAS NOT BEEN APPROVED IN WRITING BY THE TESTING AUTHORITY IS CONSIDERED AS BREACHING AS NZS 4013 WARN...

Страница 9: ...ut 10 15 minutes every morning during burning season 2 Burn heater with draft control wide open for about 10 15 minutes every time you apply fresh wood This allows the wood to achieve the charcoal stage faster and burns up any unburned gas vapours which might otherwise be deposited within the system 3 Only burn seasoned wood Avoid burning wet or green wood Seasoned wood has been dried at least one...

Страница 10: ...10 Regency Albany Freestanding Wood Fire maintenance Note Thermodisc temp switch in the fan control circuit Heater Thermodisc must come up to operating temperature for fan to operate See page 8 ...

Страница 11: ...mbly 12 8010609 Ash Lip Panel 13 6150223 Fan Assembly fan only 14 1141400 Metal lip inside firebox 15 8010115 Glass Retainer Bracket 16 3720101 Door rope seal 5 ft 17 1141004 Rear Baffle Brick Support Bar 18 1211500 Latch Bracket 19 8010614 Hinge Bracket 20 1211201 Inner Back Shield 21 1151700B Air Slide Fasteners 3 pcs 22 8010611 Steel baffie 23 7510206 Cast Plate Set 24 1141704B Friebrick Retain...

Страница 12: ...12 Regency Albany Freestanding Wood Fire NOTES notes ...

Страница 13: ...Regency Albany Freestanding Wood Fire 13 NOTES notes ...

Страница 14: ...harges will apply It is the general practice of Regency Fireplace Products to charge for larger higher priced replacement parts and issue credit once the replaced component has been returned to Regency Fireplace Products and evaluated for manufacturer defect The authorised selling dealer is responsible for all in field service work carried out on your Regency product Regency Fireplace Products wil...

Страница 15: ...d Aber Holdings 28 30 Division St 1 3 Conquest Way 17 Mainstreet Place Welshpool WA 6106 Hallam VIC 3803 Te Rapa Ha 3200 08 9350 2200 03 9799 7277 07 849 7585 NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Страница 16: ..._____________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay informed about the current promotions events and...