Manual –TC.GXS
2016-09-16
32 / 43
Template V02.11
5.2.5.
System load connection
Possible injury and damage due to arcing!
•
On reversal of the DC connections.
Very high short circuit currents through the internal free-
wheeling diodes can cause arcing.
Avoidance:
⇒
On completion of connection work, check the cables
connected.
DC-
DC+
DC+
DC-
1
2
Fig. 10 Connection of DC plus and DC minus in parallel
-1-
,
serial device mode
-2-.
Load connection
The load is connected to terminals DC positive and DC negative
according Fig. 10
Please note the following points:
•
For installation location refer to TC.GSS manual
•
The system must be electrically isolated on the system side and
load side and secured against switching on.
•
Pay attention to ensure that all DC connections are connected
correctly.
CAUTION