background image

-5-

boiling process will remove any carbon dust that formed as a result of shipping.

It will also remove any air bubbles present in the carbon. Failure to complete

this step may result in water not flowing through the filter cup.

NOTE: The filter cup should be replaced every two months or whenever

an undesirable taste is detected in the distilled water.

Your distiller is now ready for use.

NOTE:  Be  sure  to  place  the  distiller  in  a  location  that  provides  adequate

ventilation during operation,

with at least 4 inches (10 cm) of clearance to the

sides and back, and 3 inches (8 cm) to the top of the unit. Do not operate the

distiller in an enclosed area such as a cupboard or cabinet. The distiller must be

operated in air temperatures of 40˚F-110˚F (5˚C-45˚C).

INSTRUCTIONS FOR MAKING DISTILLED WATER

1. Place the distiller on a dry, level surface in a well ventilated area. Plug the

cord into a properly grounded rated voltage AC electrical outlet ONLY.

2. Remove the boiling chamber from the distiller by grasping its handle and

pulling it straight out of the distiller chassis. Do not lift up when pulling

the boiling chamber out of the chassis.

CAUTION: To prevent personal injury, burn and/or scald injury, do not

remove the boiling chamber until i

t has cooled completely.

3. Remove the boiling chamber’s cap by turning it counterclockwise. Note

the four tabs at the base of the boiling chamber’s fill opening.

4. Fill the boiling chamber with cold

tap water to the bottom of the four

tabs which equals 1 gallon (4 liters) .

Do not over fill the boiling chamber .

Overfilling the boiling chamber

may  result in leakage, electrical

failure, electrical hazard, or

damage to the distiller.

5. Replace the boiling chamber’s cap

by turning it clockwise.

6. Make sure the baffle is in place and

its securing nut is tightened. To do

this, insert the long end of the baf fle,

flat side down into the spout and

secure with the nut. The hole on the

flat side of the baffle should be facing

down. It is important that you tighten

Tabs

Water

Fill

Level

Start

Button

Boiling

Chamber Cap

Baffle

Содержание W 10000 series

Страница 1: ...To prevent personal injury or property damage read and follow the instructions and or warnings in this use and care guide COUNTERTOP WATER DISTILLER Model No W 10000 Series USE CARE GUIDE ...

Страница 2: ...le of reducing many impurities which can be found in tap water With minimum maintenance your distiller will provide convenient trouble free operation Distillation naturally dependable Using nature s own design for recycling water distillation reduces impurities through the process of evaporation and condensation As the water is heated it turns into vapor which rises leaving most impurities behind ...

Страница 3: ... Water Bottle 4 Sanitize the Water Bottle 4 Prepare the Carbon Filter 4 5 Instructions For Making Distilled Water 5 7 Cleaning Instr uctions Boiling Chamber 7 8 Water Bottle 8 Outside Sur faces 8 Carbon Filter 8 Troubleshooting Guide 8 10 Warranty and Customer Service Information Back Cover 1 ...

Страница 4: ...w the boiling chamber to cool before removing it from the distiller Do not let the cord touch hot surfaces or hang over the edge of a counter or table Do not use the distiller if it or its cord is damaged or not working pr operly Return the unit to your authorized distributor for examination and or repair Avoid using extension cords Your distiller its boiling chamber cord and plug should not be im...

Страница 5: ...that it will not drape or hang over the edge of a countertop or tabletop where it can be pulled on by childrenortrippedover To preventelectricshock injury orfire theelectrical rating of the extension cord you use must be the same as or more than wattageofthedistiller wattageisindicatedonthebottomofthedistiller Plug distiller into rated voltage AC grounded electric outlet ONLY rated voltage found o...

Страница 6: ...quids other than distilled water Liquids other than distilled water may transfer a taste or odor to the water bottle TO SANITIZE WATER BOTTLE Add 4 3 4 ounces 150 ml of 3 hydrogen peroxide solution H2O2 to the water bottle Fill the bottle with hot 160 F 71 C distilled or tap water Do not install the carbon filter at this time Cap the water bottle and shake the vigorously Let stand for twenty minut...

Страница 7: ...AC electrical outlet ONLY 2 Remove the boiling chamber from the distiller by grasping its handle and pulling it straight out of the distiller chassis Do not lift up when pulling the boiling chamber out of the chassis CAUTION To prevent personal injury burn and or scald injury do not remove the boiling chamber until i t has cooled completely 3 Remove the boiling chamber s cap by turning it counterc...

Страница 8: ...ydamagetheboilingchambermust be fully engaged prior to start up 9 Press the start button at the base of the boiling chamber NOTE Thebuttonwillglowwhentheboiling chamber is heating however the light will go out and the boiling chamber will stop heating if electrical power to the boiling chamber is interrupted or stopped If this occurs press the start button again to restart the distillation cycle 1...

Страница 9: ...the distiller NOTE The water bottle has been designed to hold one gallon 4 liters of water and to provide enough space so that the carbon filter does not remain in contact with the distilled water Therefore the water bottle will not fill completely Once the distillation cycle is complete the water bottle may be placed in the refrigerator and used to dispense the distilled water The filter may be l...

Страница 10: ...ttle OUTSIDE SURFACES Use a common household glass or appliance cleaner or a damp soft cloth to cleanthedistiller soutsidesurfaces Donotuseabrasiveorsolventbasedcleaners Do not spray cleaning products directly onto the distiller Thedistiller scoolingsystemvents seediagramonpage4 shouldbevacuumed occasionally or cleaned with a soft brush to remove dust and debris Failure to do so may cause the dist...

Страница 11: ...in the Assure that this fitting is spout of the boiling tightened before each use chamber The baffle must be installed with the flat side down this means that the hole is down and the narrow end inser ted into the spout of the boiling chamber See page 6 The distiller is not in a well Distiller must be operated in ventilated area a well ventilated area for proper heat dissipation Machine is equippe...

Страница 12: ... chassis so that both the boiling chamber and the electrical connection are tightly joined See page 6 The o ring is damaged or If damaged replace o ring missing from the baffle Make sure the o ring is properly placed on the baffle fitting in the circular groove See page 6 The flat gasket between Replace gasket the boiling chamber spout and baffle is missing or damaged ...

Страница 13: ...ur authorized distributor for all warranty parts and service needs For additional information call Consumer Service at 262 626 8623 Regal Ware Inc 1675 Reigle Drive Kewaskum WI 53040 USA Printed in USA 2006 Regal Ware Inc ...

Отзывы: