Rega Elicit-R Скачать руководство пользователя страница 6

 

 

INSTALLATION & VENTILATION  

 

The 

Elicit-

amplifier will work well on most surfaces, such as a shelf or a table, 

provided there is sufficient air around the heat sinks to prevent overheating. If using 
a  turntable,  avoid  magnetic  interference  by  positioning  the  amplifier  as  far  away 
from the turntable as the tonearm lead will allow. If possible, place it to the left of the   
turntable. Keep other equipment away from the amplifier. Due to the layout of 

Rega’s

 

amplifier  circuit  designs,  they  are  virtually  insusceptible  to  electro  magnetic       
interference,  and  by  virtue  of  the  case,  emit  practically  no  electro  magnetic         
radiation.  However,  placing  any  electronic  equipment,  such  as  sensitive  phono      
amplifiers close together may impair the performance of one or both items.  

Never

 

stack other Hi-Fi components on top of the 

Elicit-

R

 

 

 

 

 

The heat produced by the 

Elicit-

R

 

amplifier is dispersed to the air via the heat sinks 

mounted  on  either  side  of  the  product.  Please  ensure  the  side  section  is  always    
exposed to allow for sufficient airflow resulting in adequate cooling of the amplifier. If 
the 

Elicit-

R

 

is driven at high volume for a long period it will become quite warm. This 

is entirely acceptable and as long as there is sufficient ventilation the amplifier will 
continue to work normally. 

Never

 place the amplifier on carpets, rugs or bedding. Do 

not force objects into the unit’s ventilation openings above or below the sides. 

            Do not touch the heat sinks                   They can become very hot.

 

Содержание Elicit-R

Страница 1: ...Elicit R Integrated amplifier...

Страница 2: ...ON VENTILATION 4 REAR PANEL CONNECTIVITY 5 6 PHONO LINE INPUT 7 8 FRONT PANEL 9 VOLUME CONTROL LED DIMMER FUNCTION 10 THERMAL CUT OUT DC PROTECTION 11 OPERATING TEMP SHORT CIRCUIT PROTECTION 12 REMOTE...

Страница 3: ...ped attenuator volume control The Elicit R includes a high quality built in moving magnet phono stage which can be switched off by the user if so required A simple switch on the rear panel switches to...

Страница 4: ...cit II by combining the Brio R power amplifier circuit the Elicit II FET discrete line pre amplifier circuit and a stepped attenuator volume control Improvements have also been made to the Brio R powe...

Страница 5: ...Brio R was born after extensive research by our engineers to develop a low source impedance emitter follower Class A driver stage This is based around a complementary pair of 150w Sanken Darlington ou...

Страница 6: ...g any electronic equipment such as sensitive phono amplifiers close together may impair the performance of one or both items Never stack other Hi Fi components on top of the Elicit R The heat produced...

Страница 7: ...ost types of AM FM and DAB tuners and can also be used as a CD input suitable for use with any CD Blu ray and DVD source All inputs other than the Direct and Phono input are at standard line level and...

Страница 8: ...l Record Output Link This output is in parallel to the Record output and can be used to drive ancillary components like headphone amplifiers etc when a signal unaffected by the volume control and sele...

Страница 9: ...be in the in position and the line source must be connected to the phono sockets on the right looking at the back The phono line Input 1 can be used as two separate inputs These inputs are selected b...

Страница 10: ...crease the level to make sure the signal is ok and not excessive in level distorted or muddy sounding which would be the case if the incorrect input has been used for a line level signal Switching of...

Страница 11: ...e switching on again so that the self test circuitry can complete its reset cycle Input Selection The inputs are selected by firstly pressing the input selector switch to the left of the input LED s t...

Страница 12: ...of the volume control this is calibrated in 4dB steps across the total gain of the volume range The left and right channels are matched and balanced within 0 2dB ensuring a centrally placed sound stag...

Страница 13: ...h level driving of a difficult load If it occurs under normal conditions there could be a problem with insufficient airflow around the heat sinks or a fault with the loudspeakers In this case it is ad...

Страница 14: ...shorted the fold back short circuit protection will protect the output stage from excessive currents This protection circuit is not placed in the audio signal path and therefore does not affect sound...

Страница 15: ...supplied is a system remote handset It allows you to operate all the various remote controllable functions of this and many other Rega products Batteries included 2 x AAA Alkaline RC CODE Phillips RC5...

Страница 16: ...r 105 Watts into 8 Line inputs input 1 switch set to line 1 5 and record 196mV load 10K Phono input 1 switch set to phono 2mV Load 47K in parallel with 220pF Direct input 760mV Load 50K Power amplifie...

Страница 17: ...100Hz to 20KHz Direct 12Hz 0 5dB to 95KHz 3dB THD Noise at 1dB blow clip into 8 Direct input Power amplifier typically 0 003 at 1KHz measurementbandwidth 22Hz to 22KHz Line input typically 0 01 at 1K...

Страница 18: ...OWNERS LOG 1 Owner Date Where purchased 2 Owner Date Where purchased 3 Owner Date Where purchased 16...

Страница 19: ...Rega Research Ltd exceptional Hi Fi designed and made in ENGLAND...

Отзывы: