Rega Atlas MK2 Скачать руководство пользователя страница 4

2

Operation

A 9 V battery must be installed upon first 

use. The battery compartment is located 

on the bottom of the unit. If the battery is 

low, “Bat” will show on the display.

To operate, first switch the power on 

via the rocker switch located on the 

back panel. The display will light up, first 

showing 

8.88

 and then 

0.00

. The display 

will then switch off, however, the power 

indicator will remain illuminated green. 

When the indicator is green, the gauge is 

ready to use. If a weight is placed on the 

measurement pad, the display will activate 

and display the measured force. If the 

indicator illuminates red, this indicates 45 

seconds have elapsed without the Atlas 

detecting any weight and the device has 

gone into sleep mode to conserve battery. 

To wake the Atlas from sleep mode, simply 

press the ‘zero/wake’ button on the top 

panel. The gauge will re-zero itself and go 

back to an active state where the display 

is off but the power indicator illuminates 

green.

Once ready to measure tracking force, 

remove your platter mat, zero the anti-

skate/bias, and lower the tonearm queuing 

device. Place the Atlas on the platter such 

that the edge of the front guard aligns with 

the edge of the platter, as shown.

To ensure the accuracy of the 

measurement, re-zero the gauge by 

pressing the ‘zero/wake’ button on the 

top panel once the gauge has been 

placed on the turntable, if possible.  If 

any part of your turntable is suspended, 

the gauge may need to be re-zeroed on 

a hard, flat surface and then transferred 

to the platter (the gauge can be kept 

from entering a sleep state by keeping a 

weight on the measurement pad). Also, 

ensure that there are no fibrous materials 

or other obstructions underneath the 

measurement arm.

Once the Atlas is on the platter and ready 

to measure, simply lift the tonearm using 

the finger lift and gently place it down so 

that the stylus makes contact with the 

centre of the measurement pad. If the 

stylus is off-centre, this will not affect 

the accuracy of the measurement. After a 

brief settling time of approximately three 

seconds, the tracking weight should be 

shown as a stable reading.

After finishing measurement, simply switch 

off the Atlas with the rocker switch on 

the back. Store in a dry, temperate area, 

ensuring the pad will not be at risk from 

errant snags and other accidental damage.

Although the Atlas is designed to be 

maintenance free, certain events such 

as severe shock may necessitate 

recalibration.

If your Atlas displays 

CAL

, it may require 

servicing by a dealer, however you must 

check the following before returning the 

unit.

CAL

 may be displayed if the set-up 

procedure is not followed properly. This 

includes issues such as moving the unit 

during its zeroing process, not placing 

the unit on a level surface, or anything 

contacting the balance arm.

If 

CAL

 is displayed, reset the unit ensuring 

all user instructions are correctly followed 

before returning for service.

Отзывы: