Error Messages and Troubleshooting
57
Main Menu (v2.6)
REFUsol 50K-3T
982081 | 03 | 2021-03
En
gl
is
h
D
eu
ts
ch
ID49 Consist
-
ent
-
Fault_VGrid
The comparison of
the AC voltage
readings between
the master DSP
and slave DSP is
not consistent -
failed.
ID49-ID55 are internal faults of the inverter, switch off the DC switch, wait 5 minutes
and switch on the DC switch again. If no troubleshooting is possible, contact REFU
Service.
ID50 Consist
-
entFault_F
-
Grid
Comparison of AC
frequency read
-
ings between
master DSP and
slave DSP is not
consistent - failed.
ID51 Consist
-
entFault_DCI
Comparison of DC
current readings
between master
DSP and slave
DSP is not consist
-
ent - failed.
Tab. 8:
Event list
with error and information messages
ID
Event name Event description Measure