Technical data
8 — English
EEHR Electric screw-in heating element —
18.05.2018
4
Technical data
Note!
The following values apply for all variants:
•
Permissible ambient temperature at the housing:
•
Permissible minimum content of the water tank:
•
Permissible overpressure:
35 °C
200 l
Max. 10 bar
1
60 mm AF open-ended spanner fixture
6
Nameplate (on the bottom)
2
Warning sign
7
G 1 ½ B screw-in thread
3
Temperature control knob
8
Spacer plate for installation lengths larger than 240 mm
4
Indicator lamp
9
Heating elements
5
Cover, safety temperature limiter
Type
Installation
length
(L) mm
Width
(W) mm
Height
(H) mm
Housing
length
(G) mm
Electric supply
V
Capacity
KW
Power density
W/cm
2
Type of
protection
EEHR 2,0 KW
320
88
88
118
~230 or 3~400
2.0
7.5
IP 45
EEHR 2,5 KW
390
88
88
118
~230 or 3~400
2.5
6.3
IP 45
EEHR 3,0 KW
390
88
88
118
~230 or 3~400
3.0
7.6
IP 45
EEHR 3,8 KW
430
88
88
118
3~400
3.8
8.5
IP 45
EEHR 4,5 KW
470
88
88
118
3~400
4.5
8.5
IP 45
EEHR 6,0 KW
5
00
88
88
118
3~400
6.0
10
.
2
IP 45
EEHR 7,5 KW
720
88
88
118
3~400
7.5
8.1
IP 45
EEHR 9,0 KW
780
88
88
118
3~400
9.0
8.8
IP 45
Содержание EEHR 2,0 KW
Страница 2: ......
Страница 4: ...4 Deutsch EEHR Elektro Einschraubheizk rper 18 05 2018...
Страница 16: ...4 English EEHR Electric screw in heating element 18 05 2018...
Страница 28: ...4 Fran ais EEHR Corps de chauffe lectrique visser 18 05 2018...
Страница 40: ...4 EEHR 18 05 2018...
Страница 41: ...EEHR 18 05 2018 5 1 Reflex Winkelmann GmbH 2 2 1 2 2 8...
Страница 42: ...6 EEHR 18 05 2018 2 3 2 4 VDI 2035 DIN 1988 VDI 2035 2 5 14 dH 7 dH 90 C 2 6...
Страница 45: ...EEHR 18 05 2018 9 5 5 1 5 2 VDE 150 130 1 2 70 60 3...
Страница 46: ...10 EEHR 18 05 2018 5 3 5 3 1 1 400 2 230 3 5 3 2 1 2 3 4 5 6 7 8 9 IP54 10 11 12...
Страница 47: ...EEHR 18 05 2018 11 6 6 1 70 C 70 C 1 75 C 75 C 2 3 4 70 C 70 C 5 W551...
Страница 48: ...12 EEHR 18 05 2018 7 400 400 12 C 20 C 7 1 12 7 1 12 C 1 2 3 4 5 6...
Страница 49: ...EEHR 18 05 2018 13 8 7 dH 60 C 8 1 8 2...
Страница 51: ......