MI8O4 / MO4L
QUICK INSTALLATION GUIDE
R
EE
R S.p.A.
Via Carcano 32, 10153 Torino Italia
2
Tel. +39 0112482215 r.a. Fax +39 011859867
Sito web: www.reersafety.com - email: [email protected]
C) MORSETTIERE - TERMINAL BLOCKS - BORNIERS - ANSCHLUSSKLEMMEN - TERMINALES
PIN
SIGNAL
TYPE
DESCRIPTION
OPERATION
MI8O4
MO4L
1
24VDC
24VDC
-
24VDC power supply
-
2
NODE_SEL0
NODE_SEL0
Input
Node selection
(see following table)
Input (
"type B"
according to
EN 61131-2)
3
NODE_SEL1
NODE_SEL1
Input
Input (
"type B"
according to
EN 61131-2)
4
0VDC
0VDC
-
0VDC power supply
-
5
OSSD1
OSSD1
Output
Solid State Safety Output 1
PNP active high
6
OSSD2
OSSD2
Output
Solid State Safety Output 2
PNP active high
7
REST_FBK1/
STATUS1
REST_FBK1/
STATUS1
Input/
Output
Feedback/Restart 1
Input (according EN 61131-2)
SIL 1/PL c
PNP active high
8
REST_FBK2/
STATUS2
REST_FBK2/
STATUS2
Input/
Output
Feedback/Restart 2
Input (according EN 61131-2)
SIL 1/PL c
PNP active high
9
OSSD3
OSSD3
Output
Solid State Safety Output 3
PNP active high
10
OSSD4
OSSD4
Output
Solid State Safety Output 4
PNP active high
11
REST_FBK3/
STATUS3
REST_FBK3/
STATUS3
Input/
Output
Feedback/Restart 3
Input (according EN 61131-2)
SIL 1/PL c
PNP active high
12
REST_FBK4/
STATUS4
REST_FBK4/
STATUS4
Input/
Output
Feedback/Restart 4
Input (according EN 61131-2)
SIL 1/PL c
PNP active high
13
OUT_TEST1
Output
Short circuit detection output
PNP active high
14
OUT_TEST2
Output
Short circuit detection output
PNP active high
15
OUT_TEST3
Output
Short circuit detection output
PNP active high
16
OUT_TEST4
Output
Short circuit detection output
PNP active high
17
INPUT1
Input
Digital input 1
Input (according EN 61131-2)
18
INPUT2
Input
Digital input 2
Input (according EN 61131-2)
19
INPUT3
Input
Digital input 3
Input (according EN 61131-2)
20
INPUT4
Input
Digital input 4
Input (according EN 61131-2)
21
INPUT5
Input
Digital input 5
Input (according EN 61131-2)
22
INPUT6
Input
Digital input 6
Input (according EN 61131-2)
23
INPUT7
Input
Digital input 7
Input (according EN 61131-2)
24
INPUT8
Input
Digital input 8
Input (according EN 61131-2)
CONFIGURATION NODE SEL
NODE_SEL0
(PIN 2)
NODE_SEL1
(PIN 3)
NODE 0
0 (or not connected)
0 (or not connected)
NODE 1
24VDC
0 (or not connected)
NODE 2
0 (or not connected)
24VDC
NODE 3
24VDC
24VDC
Refer to the manual for wiring details in the different operation mode
D) ESEMPI DI CONFIGURAZIONE - CONFIGURATION EXAMPLE - EXEMPLE DE CONFIGURATION - KONFIGURATIONSBEISPIEL - EJEMPLO DE CONFIGURACIÓN
Configuration with 2 dual channel outputs
(safety category SIL3/Pl e)
Configuration with 4 single channel outputs
(safety category SIL3/Pl e)