Reer Mosaic MCT1 Скачать руководство пользователя страница 2

 

 

 

MCT1 / MCT2

 

QUICK INSTALLATION GUIDE

 

R

EE

R S.p.A.

 Via Carcano 32, 10153 Torino Italia 

Tel. +39 0112482215 r.a. Fax +39 011859867 
Sito web: www.reersafety.com - email: [email protected] 

 

C) MORSETTIERE - TERMINAL BLOCKS - BORNIERS - ANSCHLUSSKLEMMEN - TERMINALES 

 

 

PIN 

CABLE 

CONNECTIONS 

SIGNAL 

TYPE 

MCT1 

MCT2 

 

24VDC 

24VDC 

Power supply 24VDC 

 

n.c. 

n.c.

 

 

BRAIDING CH1 

BRAIDING CH1 

 

0VDC 

0VDC 

Power supply 0VDC 

 

n.c. 

n.c. 

 

n.c. 

n.c. 

 

n.c. 

BRAIDING CH2 

 

 

n.c. 

n.c. 

First pair 

twistate 

conductors 

CH1 - A 

CH 1 - A 

Be sure to connect to the corresponding 

terminals of the remote MCT: 

A <-> A 
B <-> B 

C <-> C 

D <-> D 

BRAIDING

 <-> 

BRAIDING 

 

You can also connect CH1 with CH2 (MCT2) 

10 

CH1 - B 

CH 1 - B 

11 

Second pair 

twistate 

conductors 

CH1 - C 

CH 1 - C 

12 

CH1 - D 

CH 1 - D 

13 

First pair 

twistate 

conductors 

n.c. 

CH 2 - A 

14 

n.c. 

CH 2 - B 

15 

Second pair 

twistate 

conductors 

n.c. 

CH 2 - C 

16 

n.c. 

CH 2 - D 

 

MCT1 

=> 1 independent connection channel 

 

MCT2

 => 2 independent connection channels 

 

 

The system response time does not change with the use of MCT modules.

   

 

  Refer to the manual for wiring details in the different operation mode

 

 

D) ESEMPI DI CONFIGURAZIONE - CONFIGURATION EXAMPLE - EXEMPLE DE CONFIGURATION - KONFIGURATIONSBEISPIEL - EJEMPLO DE CONFIGURACIÓN

 

 The connection of two MCT2 can be performed by wiring a channel of your choice. 

 The connection of the MCT1 must be connected as the first or last module.   

 

The picture shows a configuration with 2 MCT1 module (first and last position) and 2 MCT2 module between them.  
To connect the MCT modules, R

EE

R advise to use a MC series cable (i.e. MC25, MC50) depending on the necessary length to be covered. 

 

 

MCT1 

MCT1 

MCT2 

MCT2 

MC cable 

MC cable 

MC cable 