www.reer.it
8540759 Rev.1
7/8
•
You can find the exact position of the barrier in the table below (distance between the first light
beam and the ground) (according to ISO 13855).
MODEL
FMC-EB2
FMC-EB2R
FMC-EB4
FMC-EB4R
FMC-EB1700
FMC-EB1700R
FMC-EB2000
FMC-EB2000R
Distance between the first light beam
(red LED) and the ground [mm]
400 300 300 300
Table 1
ALIGNMENT OF EMITTER AND RECEIVER (Fig. 4)
•
The last operation you have to perform is the emitter / receiver alignment.
•
Ensure that the stands of emitter and receiver are in a vertical position (placing a spirit level (
A
) on
the top end of each stand). Perform leveling fine adjustments by means of the hexagonal nuts of the
stand bottom (
B
).
•
Connect the light curtain / light grid. (ref. Curtain technical manual).
•
For an exact alignment of emitter and receiver, loosen the three allen screws (
C
) that fix the rotation
flange and rotate the two columns until the barrier signal LEDS light on (ref. Technical manual).
Figure 4