Operating Instructions
CE Spring Driven Cord Reels
Reelcraft International Inc. • Ph: +44 (0) 1536 406999 • Fax: +44 (0) 1536 406777
Unit 17 - Cronin Courtyard, Weldon South Industrial Estate, Corby - Northamptonshire NN18 8AG
[email protected] • www.reelcraft.com/europe
Form# 1290-1116 Rev: 10/2018
WARNING: Even low voltage can cause
irreparable damage or death! Exercise
extreme caution while operating or
servicing this equipment.
IMPORTANT
Read this manual carefully
before installing,
operating or servicing this
equipment.
Personal injury and/or equipment damage may
result if proper safety precautions are not
observed.
• Ensure that only a qualified electrician
installs/services this equipment.
• Ensure that power supply voltage does not
exceed maximum voltage rating of reel.
• Ensure that reel is properly installed before
connecting to power supply.
• Ensure that all electrical power is removed
from reel before servicing.
• A high-tension spring is contained within the
reel. Exercise extreme caution.
• Check for frayed and/or broken wires before
each use. Pull cord from reel by grasping the
cord itself, not the work device.
• If an electrical malfunction should occur,
remove power from reel immediately.
• Ensure that reel, cord, and equipment being
serviced are properly grounded. Use an
ohmmeter to check ground continuity.
• If reel ceases to unwind or rewind, remove
power immediately. Do not pull or jerk on
electrical cord!
• Treat and respect the reel as any other piece
of machinery, observing all common safety
practices.
Safety Precautions
L 4000 118
L 4545 123 X 118 L 5550 124 X 118 L 70100 123 X 118
L 4100 118
L 5000 118
L 5700 118
L 70100 124 118
L 4500 118
L 5500 118
L 70100 118
L 70100 124 X 118
L 4000
L 4100
L 4500
L 5000
L 5500
L 5700
A
327 mm 365 mm 448 mm 448 mm
B
321 mm 362 mm 425 mm 425 mm
C
203 mm 248 mm 248 mm 248 mm
D
64 mm
64 mm
64 mm
64 mm
E
238 mm 267 mm 267 mm 318 mm
F
44 mm
54 mm
54 mm
54 mm
L 70000
with
pigtail
L 70000
bare
reels
A
514 mm 514 mm
B
502 mm 502 mm
C
198 mm 198 mm
D
98 mm
98 mm
E
298 mm 318 mm
Part No.
Cable
Nominal
AC Voltage
Nominal Output with Cable Weight
Fully Wound
Unwound
L 4000 118
15m H07RN-F 3G1.5*
220 V
1430 W
1430 W
10 kg
L 4100 118
12m H07RN-F 4G1.5*
220 V
1100 W
1100 W
10 kg
L 4500 118
13.5m H07RN-F 3G2.5*
220 V
3520 W
3520 W
10 kg
L 5000 118
10.5m H07RN-F 3G6*
220 V
3300 W
3300 W
13 kg
L 5500 118
15m H07RN-F 3G2.5*
220 V
3520 W
3520 W
16 kg
L 5700 118
15m H07RN-F 3G6*
220 V
3300 W
3300 W
17 kg
L 70100 118
30m H07RN-F 3G2.5*
220 V
3520 W
3520 W
26 kg
L 70100 124 118
30m H07RN-F 4G4*
220 V
3520 W
3520 W
26 kg
L 4545 123 X 118 13.5m H03RN-F 3G2.5
220 V
3520 W
3520 W
13 kg
L 5550 124 X 118
15m H07N-F 4G4
220 V
3520 W
3520 W
24 kg
L 70100 123 X 118 30m H07RN-F 3G2.5
220 V
3520 W
3520 W
39 kg
L 70100 124 X 118
30m H07RN-F 4G4
220 V
3520 W
3520 W
44 kg
*NOTE: