background image

Operating Instructions

CE Spring Driven Cord Reels

Reelcraft International Inc.  •  Ph: +44 (0) 1536 406999  •  Fax: +44 (0) 1536 406777

Unit 17 - Cronin Courtyard, Weldon South Industrial Estate, Corby - Northamptonshire NN18 8AG

[email protected]  •  www.reelcraft.com/europe

Form# 1290-1116  Rev: 10/2018

WARNING:  Even low voltage can cause 

irreparable damage or death!  Exercise 

extreme caution while operating or 

servicing this equipment.

IMPORTANT

Read this manual carefully 

before installing, 

operating or servicing this 

equipment.

Personal  injury  and/or  equipment  damage  may         

result if proper safety precautions are not 

observed.

• Ensure that only a qualified electrician 

   installs/services this equipment.

• Ensure that power supply voltage does not

   exceed maximum voltage rating of reel.

• Ensure that reel is properly installed before 

   connecting to power supply.

• Ensure that all electrical power is removed 

   from reel before servicing.

• A high-tension spring is contained within the    

   reel. Exercise extreme caution.

• Check for frayed and/or broken wires before

   each use. Pull cord from reel by grasping the 

   cord itself, not the work device.

• If an electrical malfunction should occur, 

   remove power from reel immediately.

• Ensure that reel, cord, and equipment being 

   serviced are properly grounded. Use an 

   ohmmeter to check ground continuity.

• If reel ceases to unwind or rewind, remove

   power immediately. Do not pull or jerk on

   electrical cord!

• Treat and respect the reel as any other piece 

   of machinery, observing all common safety 

   practices.

Safety Precautions

L 4000 118

L 4545 123 X 118 L 5550 124  X 118 L 70100 123 X 118

L 4100 118

L 5000 118

L 5700 118

L 70100 124 118

L 4500 118

L 5500 118

L 70100 118

L 70100 124 X 118

L 4000

L 4100

L 4500

L 5000

L 5500

L 5700

A

327 mm 365 mm 448 mm 448 mm

B

321 mm 362 mm 425 mm 425 mm

C

203 mm 248 mm 248 mm 248 mm

D

64 mm

64 mm

64 mm

64 mm

E

238 mm 267 mm 267 mm 318 mm

F

44 mm

54 mm

54 mm

54 mm

L 70000 

with 

pigtail

L 70000

bare 

reels

A

514 mm 514 mm

B

502 mm 502 mm

C

198 mm 198 mm

D

98 mm

98 mm

E

298 mm 318 mm

Part No.

Cable

Nominal 

AC Voltage

Nominal Output with Cable Weight

Fully Wound

Unwound

L 4000 118

15m H07RN-F 3G1.5*

220 V

1430 W

1430 W

10 kg

L 4100 118

12m H07RN-F 4G1.5*

220 V

1100 W

1100 W

10 kg

L 4500 118

13.5m H07RN-F 3G2.5*

220 V

3520 W

3520 W

10 kg

L 5000 118

10.5m H07RN-F 3G6*

220 V

3300 W

3300 W

13 kg

L 5500 118

15m H07RN-F 3G2.5*

220 V

3520 W

3520 W

16 kg

L 5700 118

15m H07RN-F 3G6*

220 V

3300 W

3300 W

17 kg

L 70100 118

30m H07RN-F 3G2.5*

220 V

3520 W

3520 W

26 kg

L 70100 124 118

30m H07RN-F 4G4*

220 V

3520 W

3520 W

26 kg

L 4545 123 X 118 13.5m H03RN-F 3G2.5

220 V

3520 W

3520 W

13 kg

L 5550 124 X 118

15m H07N-F 4G4

220 V

3520 W

3520 W

24 kg

L 70100 123 X 118 30m H07RN-F 3G2.5

220 V

3520 W

3520 W

39 kg

L 70100 124 X 118

30m H07RN-F 4G4

220 V

3520 W

3520 W

44 kg

*NOTE:

 Models provided without cable

Отзывы: