7. Electrical Connection 

 

Connect the plug-on display as shown in the wiring diagram. 

 
Connector assignment 

 

PIN 1 

Switch out 

PIN 2 

GND 

PIN 3 

+VS 

PIN 4 

PIN 5 

PIN 6 

PIN 7 

PIN 8 

PIN 9 

PIN 10 

PIN 11 

PIN 12 

 
 
 

Содержание A2X90-VM

Страница 1: ...A2X90 VM FT00536 0 00 0179FV A2X90 VM page 1 12 Operating Instructions for 4 20 mA loop powered 96x48 indicator Model A2X90 VM...

Страница 2: ...page 2 12 1 Contents 1 Contents 2 2 Note 3 3 Instrument Inspection 3 4 Regulation Use 3 5 Operating Principle 4 6 Mechanical Data 4 7 Electrical Connection 5 8 Commissioning 7 9 Technical Information...

Страница 3: ...Instruments are inspected before shipping and sent out in perfect condition Should damage to a device be visible we recommend a thorough inspection of the delivery packaging In case of damage please i...

Страница 4: ...t with two keys The menu steps are output to the LED display field 6 Mechanical Data The instrument is setted up for panel mounting It is fixed in place with the two clamps provided The maximum permit...

Страница 5: ...0179FV A2X90 VM page 5 12 7 Electrical Connection Connect the plug on display as shown in the wiring diagram Connector assignment PIN 1 Switch out PIN 2 GND PIN 3 VS PIN 4 PIN 5 PIN 6 PIN 7 PIN 8 PIN...

Страница 6: ...he sensor the voltage drop across the display 5 V and any other voltage losses additional evaluation cable losses Ub Us Ua 5V Us other voltage losses Switching output The operating voltage Ub at PIN 1...

Страница 7: ...selection of menu items B Upward and selection menu items A B Enter menu selection for adjustment or to exit acknowledge setting 8 2 Decimal Point Press key B until is displayed Press A B to enter adj...

Страница 8: ...menu item FS 8 5 Damping Press key B until is displayed Press A B to enter adjustment menu min 0 3 s max 20 0 s Press B or A for up and down for example 1 5 sec Press A B to acknowledge setting and re...

Страница 9: ...resis is the adjusted switching point minus 3 digits first digit resp first position right On customer s request the hysteresis can be factory set 8 8 Switching direction Press key B until is displaye...

Страница 10: ...time 0 3 20 s adjustable Data back up Non volatile FLASH MEMORY Error message HI overrange LO underflow Programming With two keys menu assisted scaling of indication decimal point gate time error mes...

Страница 11: ...A2X90 VM FT00536 0 00 0179FV A2X90 VM page 11 12 10 Order Code A2X90 VM loop powered 4 20 mA 96x48 indicator 11 Dimensions...

Страница 12: ...A2X90 VM FT00536 0 00 0179FV A2X90 VM page 12 12 Document FT00536 rev 0 00 of 18 07 2008 Draft P Bruno Verify M Stillavato Approvals A Marini...