DANGER!!!
Keep the pump equipment protected from interference by children, infirm persons,
incompetent persons, pets and wildlife.
WARNING!!!
This pump is designed for clean fresh water only, in non-hazardous locations.
It must NOT be used as a continuous duty fountain pump, or to pump dirty water, or to pump
liquids other than clean water.
WARNING!!!
It must never be used in bodies of water used for swimming or bathing or in
animal drinking containers.
PUMP CONTROLLER FUNCTION AND OPERATION:
The pump controller inside this pump is designed to be almost completely automatic, and will restart itself if the pump runs out of
water; you should not normally need to do anything. Instructions and basic function;
a)
Use for CLEAN rainwater only
b)
Do not operate on domestic generator power supply as this may damage the electronics
c)
Points d) to h) do not apply to pumps WITH FLOAT SWITCH
–
the float turns the power OFF to the pump when water level is
low, it will not turn back ON until the tank fills up again.
d)
The pump controller will stop the pump if there is no water in it
e)
It then rechecks for water several times
–
it makes the pump start each time, to try and “re
-
prime” itself (fill it back up with
water) It might “crackle & gurgle” due to air in it, as it tries to restart, th
is will do no harm to the pump. Air and water mix
may come through the pipes when this happens, this is not a warranty fault.
f)
It will check for water after some minutes, then off for 1 hour and restart again, then off for 5 hours then restart again, if
there is no water it then is off for 24 hours, and will restart automatically every 24hours, indefinitely.
g)
If it happens to do this in the middle of the night it can be annoying to the residents. In the early morning, turn it off & on
again after 1 minute and it will reset itself so it does the checking in daylight hours.
h)
You can reset the function back to the beginning anytime by turning the power off, and on again after 1 minute.
i)
If it is some days before it is expected to rain, turn off the power to the pump, at the power outlet, to save power.
j)
When the pump re-starts after a run-dry event, some air might come through the pipes, this should do no harm, and is not
a warranty fault.
TROUBLESHOOTING CHECKLIST
Check the following before requesting service or repair. A call out fee and labour cost may apply to field services.
PROBLEMS & POSSIBLE CAUSES;
1.Pump Operates When Water Tank Is Empty:
this is either the normal re-start function of the pump, or due to an airlock, or
some debris inside the pump > simple solution is to turn the power off to the pump, and turn it back on when rain fills the tank.
NOTICE:
tank level indicators are not always accurate!! Check inside the tank to be sure of the water level.
2. Pump does not run or motor runs for a short time, then stops
1. Circuit breaker or Safety Switch is off or fuse has blown > in a SAFE manner investigate why this has occurred, by process of
elimination > do not assume it is the pump > if you cannot do this safely, have a licenced Electrician check and rectify it.
2. Water level in the tank is too low > Top up or use alternative supply > or turn pump off until the tank fills
3. Electrical components have been flooded > It is likely that the pump will need to be replaced > in a SAFE manner investigate why
this has occurred, by process of elimination > do not assume it is the pump > if you cannot do this safely, have a licenced Electrician
check and rectify it.
4. Pump plug is not connected properly, or has been flooded or wet > Isolate power at main switch, remove plug & allow to dry. If
the problem continues, contact a licenced electrician to check the cause.
Содержание RPS036
Страница 1: ...Page 1 Ascento Group Australia P 1800 807 604 E csv ascento com au...
Страница 2: ...Page 2 Ascento Group Australia P 1800 807 604 E csv ascento com au...
Страница 3: ...Page 3 Ascento Group Australia P 1800 807 604 E csv ascento com au...
Страница 4: ...Page 4 Ascento Group Australia P 1800 807 604 E csv ascento com au...