READ CAREFULLY BEFORE MOUNTING AND USING THIS PRODUCT. FOR THE PUMP, REFER TO ITS MANUAL

OPERATION

The RPC32E Pressure controller orders the automatic start and stop of the water pump when opening or closing any tap or valve of the installation. When the 

water pump starts, it keeps running while any tap is opened in the system, giving a constant flow and pressure to the network. 

CONSTRUCTION CHARACTERISTICS

TECHNICAL CHARACTERISTICS

Inlet male 1 1/4’’

Outlet male 1 1/4’’

Special non return valve which avoids surges

Security system avoiding the possibility for the machine to work without 

water

Pressure gauge

Manual start switch (RESET)

Tension LED (POWER)

Pump-working LED (ON)

Security system LED (LOW WATER)

Tension: ~220/240 V

Max. Intensity: 30(16)A

Frequency: 50/60 Hz

Protection: IP65

Max. temperature of water: 60° C

Max. Flow: 12.000 l/h

Starting pressure: 1,5 bar-2,5 bar

Max. pressure for use: 10 bar

Max. Pump power: 220/240V:3CV(2200W)

HYDRAULIC CONNECTION (Fig.1)

Before proceeding with the hydraulic connection it is essential to prime the pump correctly. The electronic controller should be installed always in horizontal po-

sition with the overmolded arrow pointing to the top, connecting the inlet opening (male 1 1/4 “) directly to the pump and the outlet opening (male 1 1/4” ) to the 

network. 

ATTENTION: the water column between the pump and the highest point of the installation depends on the starting pressure. Here below, we give you a list with the 

height of the column and the maximum pressure which must supplies the pump.

ELECTRIC CONNECTION (Fig. 2)

Check the power supply to be ~220 ±10% Vac, dismount the cover 1 of the electronic circuit, and make the connections as per diagram on plate 2. The RPC32E can 

be used with a single-phase pump with electrical input greater than 16 A.). In this case the electrical connections must be made as shown in the diagram, fig.3 

WARNING

Bad connections may spoil the electronic circuit.

H07RN-F 3G1,5 type cables (Ø9÷12mm) must be used to ensure IP65 protection. 

STARTING

1.- Be sure that the pump is correctly primed, then gently open one tap. 

2.- Connect the electronic controller to the electric supply. The tension LED will turn on (POWER). 

3.-The pump starts working automatically and within a period of 20-25 seconds the pressure gauge will reach 

approximately the maximum pressure provided by the pump. During its working the corresponding LED (ON) 

will be on. 

4.-Close the tap indicated on point 1. After 10-12 seconds the pump will stop. The tension LED (POWER) will be 

the only one to remain on. 

Any problem after this procedure will be due to a defective pump priming. 

AUTOMATIC RESET FUNCTION

If the device goes into failure mode, this function will execute a series

of automatic starts to attempt to restore operation without any

manual intervention via the RESET button. The system operates

as follows:

•  10 seconds after the controller senses loss of prime and

•  turns off, it trys to restart for 10seconds,

•  Stops for 30 seconds,

•  Trys for 10 seconds,

•  Stops for 30 seconds,

•  Trys for 10 seconds,

•  Then Stops for 24 hours.

•  The pump will then try for 10 seconds, once every 24 hours from then on, and does not stop this cycle until there is water again.

•  Disconnecting the pump from power will stop the pump from completing its periodic 24hr water check.