2. The pump has come loose off the pipe inside the tank > look inside the tank with a torch to check this > if the water is above the 
pump  you  will  need  to  lower  the  water  level  so  you  can  check  this  properly  >  if  there  is  water  leaking  inside  the  tank  have  the 
original installer return and rectify this, it is not covered by the pump warranty as it is an installation issue.  
 
3. There is a leak in the pipework inside the tank > reduce the water level in the tank until you can see the top of the pump, open a 
tap to a slow dribble so the pump starts, then remove the leaf-trap off the tank and use a bright torch to inspect the pipework inside 
the tank to see if it is leaking 

 even a slight leak will cause the pump to cycle on/off/on/off > if there is water leaking inside the tank 

have the original installer return and rectify this, it is not covered by the pump warranty as it is an installation issue. 

 
5. Pump not pumping properly

 

1. Too high head or pump under specified > Check specifications. 
2. Too low water level > Check the water level in the tank, tank level indicators are not always accurate  
3. If a  check valve has been installed directly on the discharge of the pump, this  will  cause the  pump controller to  malfunction > 
Move the check valve to outside of the tank. 

 
6. Safety Switch (RCD) or Circuit Breaker trips when the pump starts 

1. Circuit is overloaded with too many appliances connected to it > contact a licenced electrician to install additional circuit  
2. Power plug is wet > refer 2.3 
3. If none of the above, the Motor may be defective > have it checked by a qualified technician 
 

7. Mains Water does not flow when power is off to the Pump 

1.This is very unlikely due to the design of the RM4000-3 system, the possible cause for this problem would be a blockage in one of 
the valves, which is not a pump warranty > have the valves disassembled and cleaned by a licensed Plumber, or replaced.  

8. Mains Water flows very slowly when power is off to the Pump 
1.The Town-water supply is usually less pressure than the pump supply. This is normal, it is not a fault.

 

If the Town-

water supply is very slo

w (a “dribble”) the possible cause for this

 would be a partial blockage in one of the valves, which is not a 

pump warranty > have the valves disassembled and cleaned by a licensed Plumber. 
2. Filter between pump and house (if fitted) is blocked - change the filter cartridge. 
3.Inlet filters on the inlet of the Toilet Cisterns and Washing Machine are blocked - turn the pump and the mains water off, 
disconnect the hoses and clean the filters.   

9. I have done all above, what do I do now? 

If you have followed all the above instructions and continue to have a problem with your RM4000 / RM5000 / RC550 system & if 
you are sure the problem is a warranty problem please contact Ascento: Ph: 1800 807 604 or email: [email protected] 
We will need your proof-of-purchase and your name, phone number and address. It also is of great assistance if you can take a 
couple of photos of the system and email these to us with your details. Note that field-service staff can usually only access in the 
hours 9:00am to 3:30pm weekdays excluding public holidays. Please be aware that if our field service agent attends and finds it is 
not a warranty problem the applicable charges must be paid by you, at the time of the visit. 

For pumps out of warranty please contact a local pump specialist 

 search internet 

for “Pump Repairs

 in my area

” 

 

Installation issues are covered by the Builders/installers warranty policy. 

OPERATING AND MAINTENANCE

 

1.

 

OPERATING:  

No further action is needed once the system is installed; it will operate automatically

 

2.

 

MAINTENANCE:  Start  by  doing

 

this  MONTHLY:  for  submersible  pumps 

  clean  the  inlet  filter  screen/first  flush  diverter 

according to manufacturers instructions. Ensure you re-fit the mesh strainer after doing this.  If you find no debris, do it 2 monthly, 
review  and  repeat  according  to  the  conditions  of  your  tank  (installations  where  there  is  a  lot  of  trees  will  need  to  be  flushed 
frequently)   
3.

 

No other periodic maintenance is usually necessary, except if low flow rate is found when the MAINS supply is in use, ask a 

licensed  Plumber  to  dissasemble  and  clean  blockages  from  the  RM4000-3  valve  assembly.  This  is  not  a  warranty  fault  it  is  a 
maintenance item. NOTICE TO PLUMBER: avoid adjusting any of the Valves as they are factory set and must not be interfered with. 
4.

 

TROUBLESHOOTING: - Refer to the Troubleshooting Guide. 

5.

 

SPARE PARTS LIST IF REQUIRED: - 

 
 
 
 
 
 
 

RainPro™ 

RM4000-3 Water Controller - Spare Parts        

 

 

Order Code 

Description 

Price inc GST* 

RMV3550 

RainPro RM4000-3 Valve Assembly 

POA 

8379 

RainPro RM4000 Pressure Controller *external pumps only* 

POA 

Pump 

As per the model supplied 

POA 

Содержание RainPro RC550

Страница 1: ...LLATION CONDITION THE PREMISES WHERE THE PUMP IS INSTALLED MUST BE PROTECTED BY AN RCD SAFETY SWITCH DO NOT INSTALL PUMPS WITHOUT THIS PROTECTION All parts shown are WaterMarked certified for Potable Water Fittings may differ from the image shown Do not adjust the PRV warranty is void if adjusted Read and follow the instructions in the pages following WMK Licence WM 022109 Australian Standard WMTS...

Страница 2: ...Page 2 Ascento Group Australia P 1800 807 604 E csv ascento com au WaterMark Quality System Doc RQS 1059 ...

Страница 3: ...Page 3 Ascento Group Australia P 1800 807 604 E csv ascento com au WaterMark Quality System Doc RQS 1059 ...

Страница 4: ...Page 4 Ascento Group Australia P 1800 807 604 E csv ascento com au WaterMark Quality System Doc RQS 1059 ...

Страница 5: ... sealed VERY well Use 15 wraps of thread seal tape on the male thread DO NOT USE glue unless you are CERTAIN that you will not drip glue inside the pump 7 Glue or other substances dripped inside the pump voids warranty Do NOT fit threaded fitting to the pump then glue pipe to that fitting as glue will drip inside the pump Glue the fitting and allow it to dry BEFORE attaching the threaded fitting I...

Страница 6: ...RY REQUIREMENTS FOR ALL INSTALLATIONS For any installation of pumps supplying irrigation you must fit an 18L or larger pressure tank Set tank air pressure RPS036 set air pressure to 250kPa RPS050 set air pressure to 350kPa 17 IMPORTANT NOTICE RE THE STOPPING FUNCTION In some situations the pump will cycle a few times after each use THIS IS NOT A WARRANTY FAULT it is a normal function of the intern...

Страница 7: ...the checking in daylight hours 9 6 to 8 are not applicable for a submersible pump with float switch it will stay off until the tank fills again 10 If it is dry for a long time no rain it is best to turn the power off to the pump at the power outlet 11 A First flush diverter or similar device must be installed to prevent debris from entering the tank or a filter screen through which all the incomin...

Страница 8: ... tank or a filter screen through which all the incoming water passes before entering the tank NO WARRANTY if the pipe is less than 25mm INTERNAL DIAMETER Step 2 IF THE PUMP HAS A FLOAT SWITCH ensure it can move freely and wont get stuck against the side of the rainwater tank or baffles inside the tank Step 3 Attach Rainwater supply to the RM4000 3 Valve as shown in the diagram Step 4 Connect Disch...

Страница 9: ...INGS TO CHECK BEFORE YOU CALL FOR SERVICE WARNING SAFETY FIRST TAKE PRECAUTIONS Before servicing a pump always shut off the power supply and then make sure you are not standing in water and that there is no risk of electrical shock If the pump is direct wired to the electrical circuit contact a licensed electrician to disconnect it TROUBLESHOOTING CHECKLIST Before you call for service or repair pl...

Страница 10: ...is installed backwards arrow on valve should point in direction of flow have the installer fix this 3 Discharge shut off valve ball valve gate valve may be closed open the valve 4 Impeller or volute openings are fully or partially clogged or it might be blocked with debris disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technicia...

Страница 11: ...es which is not a pump warranty have the valves disassembled and cleaned by a licensed Plumber 2 Filter between pump and house if fitted is blocked change the filter cartridge 3 Inlet filters on the inlet of the Toilet Cisterns and Washing Machine are blocked turn the pump and the mains water off disconnect the hoses and clean the filters 9 I have done all above what do I do now If you have follow...

Страница 12: ...or replacement warranty replacement or upgrading The installation must NOT be constructed in such a manner that specialized tools or paid tradespersons or external paid contractors are required to be engaged in order to remove and or replace and or refit the pump therefore all pumps must be installed using barrel union connections to facilitate easy servicing or replacement If the rainwater tank i...

Отзывы: