Reefe 22603 Скачать руководство пользователя страница 6

www.

reefe

.com.au

Ascento Group Australia

© 

AI.062020

P: 1800 807 604

IMPORTANT INSTALLATION & WARRANTY CONDITIONS - EXTERNAL PUMPS

1) The mains supply must not exceed 500kPa refer AS/NZS 3500.1

2) The pump must have flooded suction (gravity feed of tank-water) with an inlet pipe not less than the size of the pump inlet (typically 25mm)

3) The suction must have a Y-Strainer fitted (on the inlet from tank)

4) Mains supply must have an isolation valve (ball-valve)

5) Tank supply must have an isolation valve (ball-valve)

6) ALL CONNECTIONS must be with Barrel-Unions

7) Most pump warranties are conditional upon a pump cover being fitted

IMPORTANT INSTALLATION & WARRANTY CONDITIONS - SUBMERSIBLE PUMPS

1) The mains supply must not exceed 500kPa refer AS/NZS 3500.1

2) The pump must be easily accessible for repair or servicing

3) If the pump has a float switch, ensure it CANNOT get stuck on the side of the tank or under baffles or similar -warranty service does not cover this situation.

4) Mains supply must have an isolation valve fitted (ball-valve)

5) ALL CONNECTIONS must be with Barrel-Unions

6) For underground tanks, the installation must be designed and constructed to allow easy access, for removal or replacement of the pump, warranty does not 

include costs of digging up gardens etc!

MAINTENTANCE

The RM1500-2 or RM1600-2 Valve does not require any regular maintenance however there are things you can do to ensure its most reliable operation.

• Fit a Y-Strainer

• Cleaning your gutters

• Cleaning the inlet strainer on rainwater tank

WARRANTY INFORMATION

RM1500-2 and RM1600-2 warranty for Australia and New Zealand

The RM1500-2 and RM1600-2 valve is guaranteed for a period of 2 years from the date of original purchase to be free of material or manufacturing defects. 

Should any part fail as a result of such defects within this period, the RM1500-2 and RM1600-2 valve will be repaired or replaced by the manufacturer, free of 

charge. The RM1500-2 and RM1600-2 valve also has a LIMITED LIFETIME WARRANTY on all brass components, any brass component will be replaced free of 

charge if it fails in normal use during its life.

This warranty applies in all states and territories in Australia and New Zealand. The warranty period commences on the day of the original purchase of the 

RM1500-2 and RM1600-2 valve. Evidence of this purchase must be provided when claiming repairs or replacement, it is recommended you retain all receipts.

Both warranties are subject to conditions by the original purchaser with all conditions set out in the installation and operating instructions. Failure to comply with 

these instructions, damage or breakdown caused by fair wear and tear, negligence, misuse, incorrect installation, chemical or additives in the water, corrosive or 

abrasive water, inadequate conditions, attempting repairs or accidents, are not covered by this warranty.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. If you are a consumer as defined by the Australian Consumer Law, 

you are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled 

to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. The above conditions form 

part of the instructions and do not over-ride your statutory rights.

TROUBLESHOOTING
SYMPTOM

CAUSE

REMEDY

No water is delivered from pump or 

pump performance is decreased 

Rainwater tank is empty. No Power. Isolation Valve 

is shut. Pump is not primed. Y-Strainer is blocked.

Wait for tank to fill.  

Check power supply & plug. Restart pump.  

Open isolation Valve.  

See pump owners manual on priming pump. Clean Y-Strainer.

No water is delivered from mains

No water from mains. Debris in valve.

Check isolation valve on water meter. Open bleed plug

Pump continually runs

Leak in the plumbing system. E.g. Toilet or tap 

leaking.  

Faulty pump

Repair Leak.  

Contact pump manufacturer.

RM1500-2

RM1600-2

Max Mains Pressure

500KPa

500KPa

Max Pump Pressure

600KPa

600KPa

Min Pump Pressure

350KPa

300KPa

Max Flow Rate

100L/Min

50L/Min

Max Water Temperature

50C

40C

Min Water Temperature

0C

0C

Pump Inlet 

25mm, 1” FBSP

25mm, 1” FBSP

Mains Water In

25mm, 1” FBSP

25mm, 1” FBSP

Outlet 

25mm, 1” FBSP

20mm, 3/4” FBSP

Weight

1.6Kg

0.85Kg

SPECIFICATIONS 

Meets Requirements of WMTS477/LN60075

Complies to WMTS477/LN60075 when installed by a licensed plumber

NOTE: According to WMTS477/LN60075 maximum allowable pressure in 

buildings is 500 KPa

*Ensure proper protection against freezing weather.  Complies to AS/NZS 

3500.1 when installed by a licenced plumber

Содержание 22603

Страница 1: ...www reefe com au EXPLODED VIEW INSTRUCTION MANUAL SUBMERSIBLE RAIN MAINS SYSTEM MODEL RM5000 4 PUMP RPS57E CODE 22603 PIPEWORK...

Страница 2: ...www reefe com au SUBMERSIBLE RAIN MAINS SYSTEM PARTS LIST EXPLODED VIEW Refer next page for componentry listing...

Страница 3: ...N COMPONENT 1 Stopper 25 Rubber 3 Holes 2 Suction Screen 26 Cable Gland 3 Screw 27 Earth Connector 4 Washer 28 Connector 5 Separator 29 Connector 6 Impeller 30 Screw 7 Diffuser 30b Screw 8 Washer 31 C...

Страница 4: ...Potable Water Fittings may differ from the image shown due to variations in design Do not adjust the PRV warranty is void if adjusted Read and follow the instructions in the pages following IMPORTANT...

Страница 5: ...0 300 200 100 Pressure drop kPa 0 10 15 20 25 30 Pressure drop vs flow rate Main inlet side 35 40 45 Flow Rate L min Pressure drop verssus flow rate between the mains water inlet side and the outlet o...

Страница 6: ...ces on the day of the original purchase of the RM1500 2 and RM1600 2 valve Evidence of this purchase must be provided when claiming repairs or replacement it is recommended you retain all receipts Bot...

Страница 7: ...00 807 604 ANNEX A Barrel Union WARNING GLUE DRIPPED INSIDE PUMP VOIDS WARRANTY ENSURE STRONG CONNECTION SO PUMP DOES NOT WORK LOOSE USE 15 WRAPS OF THREAD SEAL TAPE ON THE MI FITTING Ball Valve Disch...

Страница 8: ...USING A CORD THROUGH THE HANDLE NEVER LIFT THE PUMP FROM THE CABLE NO APPLIANCE LASTS FOREVER INSTALLATION MUST ALLOW FOR REMOVAL FOR SERVICING OR REPAIRS WARRANTY SERVICE DOES NOT COVER COST OF MOVI...

Страница 9: ...ump is preferred 17 IMPORTANT NOTICE RE THE STOPPING FUNCTION In some situations the pump will cycle a few times after each use THIS IS NOT A WARRANTY FAULT it is a normal function of the internal pum...

Страница 10: ...ecommended to use flexible not rigid pipework to help avoid vibrations from the pump transmitting to the house STEP 5 Mains supply is to be connected to the RM1500 2 valve assembly through the PRV pre...

Страница 11: ...nd hollow Feel the side of the tank you can normally feel a temperature difference from where the water is to where there is none If you cannot tell that way get a torch and look in through the tank o...

Страница 12: ...s problem would be a blockage in one of the valves which is not a pump warranty have the valves disassembled and cleaned by a licensed Plumber or replaced 8 Mains Water flows very slowly when power is...

Страница 13: ...talling or servicing disconnect from the power supply A ball valve or gate valve must be fitted on the suction and the Town water backup supply where fitted A First flush diverter or similar device mu...