This.clamp.meter.has.very.good.frequency.response.due.to.the.elec-
tric.property.of.the.transformer.jaws.used..Therefore,.the.measurement.
result.contains.not.only.the.fundamental.frequency.of.50/60Hz.but.also.
the.high.frequencies.and.harmonics.superimposed.on.the.fundamental.
frequency..To.eliminate.the.effect.of.high.frequency.noise,.a.low.pass.filter.
is.designed.to.filter.out.high.frequency.signal..To.enable.the.filter,.set.the.
switch.at.the.50/60.position..The.filter’s.cut-off.frequency.is.set.at.100Hz.
with.an.attenuation.characteristic.of.approx..24dB/octave.
Wide Position
If.the.circuit.under.test.is.originated.from.a.high.frequency.generating.de-
vice.such.as.inverter,.switching.regulators,.etc.,.then.the.switch.should.be.
set.at.wide.position.to.measure.the.signal.which.contains.the.frequency.
from.40Hz-1kHz..To.confirm.the.presence.of.a.high.frequency.signal,.
switch.between.the.50/60.and.wide.position.to.see.if.there.is.a.difference..
If.the.reading.is.very.different,.then.high.frequency.signals.or.harmonics.
are.present.
AC Load Current Measurement
LOAD........LEAKAGE
1.. Set.the.rotary.switch.to.the.desired.range.and.turn.the.meter.on.by.
pressing.the.Hold.Button
2.. Press.the.trigger.to.open.the.jaw.and.fully.enclose.only.one.wire
3.. The.measured.value.will.appear.on.the.LCD.screen