REED ST-805 Скачать руководство пользователя страница 6

reedinstruments

www

com

6

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

8. MAX/Hold Button    

MAX/HOLD

                

     The MAX Hold position is used to measure the maximum level of 
     sounds. The maximum measured level is updated continuously.  
     Pressing the button a second time will release the maximum hold  
     function and allow another measurement.
     The Data HOLD function freezes the reading on the display. 
     Data HOLD Button: Press and hold the button for 2 seconds to turn 
     the Data HOLD function on or off. 

9. Microphone 
    

1/2-inch electret condenser microphone

10. Battery Cover

 

Operating Instructions

Notes

• 

Wind blowing across the microphone will bring additional  
extraneous noise. If using the instrument in the presence of wind, it is 
recommended to put the windscreen on the microphone so as not to 
pick up undesirable signals.

• 

To achieve more accurate measurements, use an extension cable 
to separate the microphone from the main body so that the effect of 
unexpected sound reflection can be eliminated.

• 

Calibrate the instrument before operation if the instrument has not  
been in use for a long period of time or was last operated under  
extreme conditions.

• 

Do not store or operate the instrument in high temperature and high 
humidity environments.

• 

Keep microphone dry and avoid severe vibrations.

• 

When not in use, please take the battery out and keep the instrument 
in a low humidity environment.

 

All manuals and user guides at all-guides.com

all-guides.com

Содержание ST-805

Страница 1: ...w com Model ST 805 Sound Level Meter Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 All manuals and user guides at all guides com a l l...

Страница 2: ...4 6 Operating Instructions 6 7 Battery Replacement 7 Safety Read the following safety information carefully before attempting to operate or service this meter Use this meter only as specified in this...

Страница 3: ...Display Update 0 5 sec Alarm Function OVER is show when input is out of range Maximum Hold Hold readings the Maximum Value with decay 1dB 3minutes Microphone 1 2 inch electret condenser microphone Cal...

Страница 4: ...low Pantone 534 Blue Black Rich Black 20 20 20 100 Blue 100 80 30 5 Yellow 0 27 100 0 Red 10 100 100 5 Yellow 0 27 100 0 Blue 100 80 30 5 Only if you REALLY need them Pantone 534 Blue 100 80 30 5 Pant...

Страница 5: ...ting Select Button A C A A Weighting For general sound level measurements C C Weighting For checking the low frequency content of noise If the C Weighted level is much higher than the A Weighted level...

Страница 6: ...2 inch electret condenser microphone 10 Battery Cover Operating Instructions Notes Wind blowing across the microphone will bring additional extraneous noise If using the instrument in the presence of...

Страница 7: ...t the microphone at the suspected noise source the sound pressure level will be displayed 4 When MAX maximum hold mode is chosen The instrument captures and holds the maximum noise level for a long pe...

Страница 8: ..._______________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _____________...