Operating Instructions
Taking a Measurement
Turn.the.meter.ON.by.pressing.the. .button..Hold.the.meter.in.a.upright.
position.so.the.ball.sensor.is.in.the.air.and.at.least.8-10cm.away.from.any.
object..Press.the.MEAS.button.and.“CAL”.will.display.on.the.LCD.screen..
The.value.must.be.below.0.5.to.be.able.to.take.accurate.measurements..
If.the.reading.is.above.0.5.you.must.turn.the.meter.off.and.move.to.a.dry.
area.to.calibrate..After.the.meter.is.calibrated.it.will.automatically.start.to.
take.measurements..To.hold.the.current.measurement.press.the.MEAS..
button.and.the.data.hold.symbol.will.appear.on.the.LCD.screen...
After.30.seconds.of.inactivity.the.meter.will.auto.power.off.
Note:
.
When.you.move.from.the.location.of.your.initial.calibration.you.
.
must.re-calibrate.the.meter
Alarm Set Mode
To.change.the.RISK.and.WET.alarm.value.turn.on.and.calibrate.the.meter..
Press.the.MEAS.button.to.put.the.meter.in.data.hold.and.press.the.SET.
button..The.RISK.symbol.will.appear.on.the.LCD.screen.and.the.value.
which.the.RISK.alarm.is.set.to..To.change.the.alarm.value.press.the.UP.
or.DOWN.buttons..Press.the.SET.button.to.save.your.setting.and.to.
change.the.WET.alarm.value..The.WET.symbol.will.appear.on.the.screen.
beside.the.WET.alarm.value..To.change.the.WET.alarm.value.press.the.
UP.or.DOWN.buttons..Press.the.SET.button.to.save.the.WET.alarm.value.
and.to.return.to.data.hold.mode..If.the.moisture.measurement.exceeds.
the.RISK.alarm.setting.the.meter.will.beep.every.second..If.the.moisture.
measurement.exceeds.the.WET.alarm.setting.the.meter.will.beep.every.
half.second.
Note:
.
The.RISK.alarm.value.is.between.0-50..The.default.setting.is.30
.
The.WET.alarm.value.is.between.50-100..The.default.setting.is.60
Backlighting
When.the.meter.is.in.data.hold,.press.the.UP.button.to.turn.the.backlighting.
on.or.off..