Specifications

Circuit: 

Custom microprocessor LSI circuit

Display: 

52mm x 38mm LCD with backlight

Conductivity Units: 

µS, mS

TDS Units: 

PPM

Salt Units: 

% (of weight)

Conductivity Probe: 

Carbon rod electrode

Auto Sampling Time: 

1 second to 9 hours

Memory Card: 

SD memory card, 1 GB to 16 GB

Sampling Time of Display:  Approx. 1 second
Data Output: 

USB/RS232 PC computer interface

Temperature Range: 

0-50°C (0-122°F)

Resolution: 

0.1°C/0.1°F

Accuracy: 

± 0.8°C/1.5°F

Operating Temperature: 

Meter: 0-50°C; Probe: 0-60°C

Operating Humidity: 

Less than 85% R.H. 

Power Supply: 

UM3/AA (1.5 V) x 6 batteries

Weight:  

515g/1.13lb

Dimensions: 

Meter: 177 x 68 x x45mm (7.0 x 2.7 x 1.9”)

 

Probe: 22mm Dia. X 120mm Length

Includes: 

Conductivity/TDS/Salt Probe  

 

and a Hard Carrying Case

Optional accessories: 

2G SD Card (SD-2GB) 

 

USB cable (USB-01 

 

Power adapter (AP-9VA-110V) 

 

Data Acquisition Software (SW-U801-WIN) 

 

Tripod (BS-6)

Visit us at www.reedinstruments.com for more information on our optional 
accessories, or e-mail us at [email protected]

[email protected]

www.

GlobalScientificSupply

.com

GLOBAL SCIENTIFIC SUPPLY

The Laboratory Supply Company!

Содержание SD-4307

Страница 1: ...f you REALLY need them Model Salt TDS Conductivity Datalogger SD 4307 reedinstruments www com Instruction Manual info GlobalScientificSupply com www GlobalScientificSupply com GLOBAL SCIENTIFIC SUPPLY...

Страница 2: ...8 9 Data Record Max Min reading 9 Backlight ON OFF 10 Datalogger 10 Auto Datalogger 10 11 Manual Datalogger 11 Checking the Time 11 Check Sampling Time Information 11 SD Card Data Structure 12 Data Tr...

Страница 3: ...ime SD memory card datalogger with a built in clock and calendar Sampling time set from 1 second to 9 hours Meter can switch to a Manual Datalogging No extra software needed just plug the SD card into...

Страница 4: ...RS232 PC computer interface Temperature Range 0 50 C 0 122 F Resolution 0 1 C 0 1 F Accuracy 0 8 C 1 5 F Operating Temperature Meter 0 50 C Probe 0 60 C Operating Humidity Less than 85 R H Power Supp...

Страница 5: ...0 01mS 200mS 20 200 0mS 0 1mS TDS Specifications Range Measurement Resolution Accuracy 200PPM 0 132PPM 0 1 PPM 2 Full Scale 1d at 23 5 C 2 000PPM 132 1 320PPM 1PPM 20 000PPM 1 320 13 200PPM 10PPM 200...

Страница 6: ...Backlight Button 3 Hold ESC Button 4 REC Enter 5 Mode Up Button 6 Range Down Button 7 Time Button 8 Logger SET Sampling Check Button 9 Stand 10 Battery Compartment 11 Battery Cover Screw 12 Tripod Fi...

Страница 7: ...lowing Display Unit Conductivity Temperature Unit C Temp Compensation Factor 2 0 per C Auto range ON Auto power off ON Datalogger Sampling Time 2 seconds Conductivity Measurement 1 When the meter is o...

Страница 8: ...ernal air bubble drift out from under the sensing head The Display will show the Total Dissolved Solids value Salt Measurement 1 When the meter is off plug the Probe Plug into the Probe Socket then po...

Страница 9: ...make other ranges 20 S range 20mS range or 200mS range after if necessary Data Record Max Min reading The data record function records the maximum and minimum readings Press the REC Button once to sta...

Страница 10: ...for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded to the SD card is defaulted used the as the decimal for example 20 6 1000 53 But in certain countri...

Страница 11: ...how the Position record number which is saved as well 2 To Change the Position Number press the Down Button and the lower position number will flash on the display Press the Up or Down Buttons to set...

Страница 12: ...x number of CDA folders is 10 Data Transfer from SD card to Computer EXCEL Software 1 After Datalogging remove the SD card from the SD card slot 2 Plug in the SD card into the Computer s SD card slot...

Страница 13: ...ling time Hour Minute Second Sd F SD memory card Format PEr C Set CD temperature compensation factor ESC Exit Advanced Settings While in the Advanced Setting function press the Esc Button to exit and...

Страница 14: ...t the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to save the setting as the default To exit Advanced Settings press the Esc Button...

Страница 15: ...no do not format the SD card 2 To format your SD card select yES and press the Enter Button The Display will show yES Enter to confirm Press the Enter Button to confirm Setting the CD Temperature Comp...

Страница 16: ...RS232 lead with the following connection will be required to link the instrument with the PC serial input Meter 3 5mm Jack Plug PC 9W D Connector Center Pin Pin 2 Ground Shield Pin 5 The 16 digit data...

Страница 17: ...eedinstruments com for more information Battery Replacement 1 When the left corner of LCD display shows it is necessary to replace the battery 2 Loosen the screws of the Battery Cover and remove 3 Rem...

Страница 18: ...____________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________...

Страница 19: ...____________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________...

Страница 20: ...____________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________...

Отзывы: