Operating Instructions

Function selection 

1)  Turn on the meter by pressing the Power Button. To turn the meter 

off, hold the Power Button for over 2 seconds.

2)  The meter has 4 measuring functions to choose from: Humidity/

Temp, Dew Point, Wet Bulb, or Type K/J Thermometer. When the 
meter is on, press and hold the Function Button. The display will 
flash “rH”, for Humidity/Temperature measurement, “dP” for Dew 
Point measurement, “_Et” for Wet Bulb measurement, and “tP” for 
Type K/J Thermometer measurement. Release the Function Button 
to choose the displayed function.

Humidity/Temperature measurement

1)  1) When the meter is off, plug the Probe into the Probe Input 

Socket, then power on the meter by pressing the Power Button.

2)  Select the “rH” function (see Function Select).
3)  Hold the Probe Handle and face the Probe Head against the mea-

suring source. The top part of the Display will show the Humidity 
value, and the lower part of the Display will show the Temperature 
value. 

Dew Point measurment

1)  Select the “dP” function (see Function Select).
2)  Hold the Probe Handle and face the Probe Head against the mea-

suring source. The top part of the Display will show the Dew Point 
value, and the lower part of the Display will show “dP”.  

Wet Bulb measurement

1)  Select the “_Et” function (see Function Select).
2)  Hold the Probe Handle and face the Probe Head against the mea-

suring source. The top part of the Display will show the Wet Bulb 
value, and the lower part of the Display will show “_Et”. 

Содержание SD-3007

Страница 1: ...Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 Model Instruction Manual Humidity Temperature Datalogger SD 3007 reedinstruments www com...

Страница 2: ...Temperature measurement 7 Dew Point measurment 7 Wet Bulb measurement 7 Data Hold 8 Data Record Max Min reading 8 Backlight ON OFF 9 Datalogger 9 Auto Datalogger 9 10 Manual Datalogger 10 Checking the...

Страница 3: ...D card into the computer and it downloads directly to EXCEL SD card capacity 1 GB to 16 GB Easy to read LCD with backlight Auto power off or manual power off Data hold record max and min reading High...

Страница 4: ...2 F Operating Humidity Less than 85 R H Power Supply UM3 AA 1 5 V x 6 batteries Weight 515g 1 13lb Dimensions 177 x 68 x 45mm 7 0 x 2 7 x 1 9 Includes Humidity Temp probe Optional accessories 2G SD Ca...

Страница 5: ...1 6 C 50 0 C 6 9 F 122 0 F R solution 0 1 Type K J thermometer Sensor Type R solution Range Accuracy Type K 0 1 C 50 0 to 1300 0 C 0 4 0 5 C 50 1 to 100 0 C 0 4 1 C 0 1 F 58 0 to 2372 0 F 0 4 1 F 58 1...

Страница 6: ...ed 10 100 100 5 Instrument Description 1 Display 2 Power ESC Backlight Button 3 Hold Button Function Button Next Button 4 REC Button Enter Button 5 SET Button Up Button Time Check Button 6 Logger Butt...

Страница 7: ...rmometer measurement Release the Function Button to choose the displayed function Humidity Temperature measurement 1 1 When the meter is off plug the Probe into the Probe Input Socket then power on th...

Страница 8: ...Button once and the mea sured value will hold on the screen and a HOLD symbol will appear Press the Hold Button once again will release the data hold function Data Record Max Min reading The data rec...

Страница 9: ...rst time the meter is used you need to adjust the clock See Advanced Settings section of this manual for instruc tions 4 Now you need to set the decimal format The numerical data struc ture downloaded...

Страница 10: ...time the measuring data along the time infor mation will be saved in memory The lower Display will show the Position record number which is saved as well 2 To Change the Position Number press the Down...

Страница 11: ...3 The folder HTA01 can hold 99 XLS files When that number has been reached the meter will then will generate a new folder with a subsequent number for example HTA02 Max number of HTA folders is 10 Dat...

Страница 12: ...Auto power OFF management bEEP Set beeper sound ON OFF tYPE Select the Thermometer to Type K or Type J t CF Select the temperature unit to C or F SP t Set sampling time Hour Minute Second Sd F SD mem...

Страница 13: ...agement 1 When the lower display shows PoFF use the Up or Down But tons to select the value yES Enable Auto Power Off or no Disable Auto Power Off 2 After selecting yES or no press the Enter Button to...

Страница 14: ...ault To exit Advanced Settings press the Esc Button Set sampling time 1 When the lower display shows SP t use the Up or Down Buttons to adjust the value to either 0 1 2 5 10 30 60 120 300 600 1800 or...

Страница 15: ...or output is a 16 digit data stream which can be utilized to the user s specific application An USB RS232 lead with the following connection will be required to link the instrument with the PC serial...

Страница 16: ...utton does not fix the error please send in the unit to our Calibration Lab for repair E mail info reedinstruments com for more information Battery Replacement 1 When the left corner of LCD display sh...

Страница 17: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Страница 18: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Страница 19: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Страница 20: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________________...

Отзывы: