www.REEDINSTRUMENTS.com

Thermo-

Hygrometer

Instruction 

Manual

R6001

1.800.561.8187 

[email protected]

REED-Direct.ca

Содержание R6001

Страница 1: ...www REEDINSTRUMENTS com Thermo Hygrometer Instruction Manual R6001 1 800 561 8187 info REED Direct ca REED Direct ca ...

Страница 2: ...umidity Calibration Procedure 6 7 Restoring Factory Settings 7 Battery Replacement 7 Accessories and Replacement Parts 7 Applications 8 Product Care 8 Product Warranty 8 Product Disposal and Recycling 9 Product Support 9 Introduction Thank you for purchasing your R6001 Thermo Hygrometer Please read the following instructions carefully before using your instrument By following the steps outlined in...

Страница 3: ...or the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Easy to use intuitive design Dual LCD readout displays temperature and humidity User selectable F C High Sampling Rate of 2 5 times sec Data hold Min Max and Relative functions Low battery indicator and auto shu...

Страница 4: ...4 to 140 F 20 to 60 C Storage Temperature 14 to 140 F 10 to 60 C Operating Humidity Range 10 to 80 Dimensions 9 5 x 2 1 x 1 3 240 x 54 x 34mm Weight 6 4oz 180g Included Carrying Case Battery Instrument Description 1 Sensor Protective Cap 2 LCD Display 3 Power Button 4 MAX MIN Button 5 Data Hold Button 6 Relative Function Button 7 Unit of Measure Button 8 Battery Cover 1 2 3 4 5 6 7 8 1 800 561 818...

Страница 5: ...FF Unit of Measure Selection Temperature When the meter is powered on press the C F button to toggle between Celsius and Fahrenheit Note The default unit of measure is Celsius C The meter will automati cally save the last selected unit of measure when turned off Data Hold Press the HOLD button to freeze the current reading on the display Press the button again to resume normal operation Note When ...

Страница 6: ... through stored measurements 5 To exit MAX MIN mode and resume normal operation press and hold the MAX MIN button for two seconds Note When in MAX MIN mode the REL and C F buttons are disabled Auto Power Off To preserve battery life the meter is programmed to turn itself off after 30 minutes of inactivity To disable this feature press and hold the HOLD button while powering on the meter When the m...

Страница 7: ...steps can be cancelled at any point by pressing the ON OFF button Restoring Factory Settings 1 Turn the meter off 2 Press the HOLD C F and power button simultaneously then release 3 When the LCD flashes press the MAX MIN button to restore factory default settings 4 A long beep will confirm factory settings have been restored The meter will then resume normal operation Battery Replacement When the ...

Страница 8: ...free of defects in material or workmanship for a period of one 1 year from date of shipment During the warranty period REED Instruments will repair or replace at no charge products or parts of a product that proves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Ins...

Страница 9: ...e contact your authorized REED distributor or REED Instruments Customer Service by phone at 1 877 849 2127 or by email at info reedinstruments com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is strictly p...

Страница 10: ...www REEDINSTRUMENTS com TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS 1 800 561 8187 info REED Direct ca REED Direct ca ...