Model

R5600

Digital Insulation Tester

Instruction

Manual

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

INSTRUMENTS

www.

.com

[email protected]

1.800.561.8187

Содержание R5600

Страница 1: ...truments www com Model R5600 Digital Insulation Tester Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 www com information itm com 1 800 561 8187 ...

Страница 2: ...ty 3 Specifications 4 5 General 4 Electrical 5 Meter Description 6 Operating Instructions 6 7 How to connect the test leads 6 How to check the test leads 7 Battery replacement 7 Measurements 7 8 Insulation Resistance Measurements 7 Low Resistance Measurements 8 AC DC Voltage Measurements 8 Power Tool Small Appliances 9 10 Motors 9 Cables 10 For service on this or any other REED product contact REE...

Страница 3: ...the conductor could result in electric shock Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired Read the operating instructions before use and follow all safety Information Caution when working with voltages above 60V DC or 30V AC RMS Such voltages pose a shock hazard Before taking resistance measurements or testing acoustic continuity dis...

Страница 4: ...ase with a dry cloth Do not use abrasives or solvents on this instruments Display Large LCD with dual display Measurement Range 200Ω 200kΩ 200MΩ 250V 200MΩ 500V 2000MΩ 1000V 750V ACV 1000V DCV Sampling Rate 2 5 times per second Zero Adjustment Automatic adjustment Over Range Indicator Number 1 of highest digit is displayed Low Battery Indication The is displayed when the battery voltage drops belo...

Страница 5: ...r Range Resolution Operation Resistance Max open Circuit Voltage Overload Protection 0 1Ω Resistance 40Ω 4 5V 250Vrms Short circuit current 200mA DC Voltage Range Resolution Accuracy Input Impedance Overload Protection 1000V 1V 0 8 3 10MΩ 1000Vrms AC Voltage 40Hz 400Hz Range Resolution Accuracy Input Impedance Overload Protection 750V 1V 1 2 10 10MΩ 750Vrms Meg OHMS Range Resolution Accuracy Termi...

Страница 6: ... 10 Battery Cover Operating Instructions How to connect test leads 1 On MΩ Range Connect the red test lead into the VΩ terminal and the black lead into the COM terminal 2 On 200Ω and ACV Range Connect the red test lead into the VΩ terminal and the black lead into terminal COM How to check the test leads Set the range select switch to the 200Ω range With the tip and alligator clip of the test leads...

Страница 7: ...a case an installation may be divided into sections each being separately tested Each section must have at least fifty outlets an outlet being a switch socket lighting point etc A switched socket counts as one outlet The minimum accept able insulation resistance is 1MΩ For a large installation the capacitance of the insulation will be high and it will take longer for it to become charged by the di...

Страница 8: ...ure For hands free operation a lock power on feature is incorporated in the press to test button Set the LOCK button to lock test voltage pressing it again will turn the tester off Low Resistance Continuity Measurements 1 Set the range switch to 200Ω Position 2 Connect the red test lead to the V Ω terminal and back to the COM terminal 3 Connect the tips of the test leads to both ends of the circui...

Страница 9: ...r then the starter must be held by some means in the ON position In the latter case the measured resistance will include the resistance of the motor wire and all other components be tween the motor and the main switch If a weakness is in dicated the mo tor and other components should be checked individually If the motor is disconnected at the motor terminals connect one megohmmeter lead to the gro...

Страница 10: ...lso disconnect opposite end to avoid errors due to leakage from other equipment Check each conductor to ground and or lead sheath by connecting one megohmmeter lead to a ground and or lead sheather and the other megohmmeter lead to each of the conductors in turn Check insulation resistance between conductors by connecting megohmmeter leads to conductors in pairs For service on this or any other RE...

Страница 11: ..._____________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ___________________________________________...

Страница 12: ..._____________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ___________________________________________...