Specifications 

Wire Verification Distance   

10,000 feet (3000 meters)

Minimum Wire Size 

 

26 gage

Power Supply 

 

9V battery

Product Certifications 

 

CE

Visual Indicator 

 

Yes (Green and Red LEDs)

Audible Indicator 

 

Yes (Pulsating Beeper, approx. 85 dB)

Fuse Protection 

 

0.5A/250V

Continuity Confirmation   

Equal to or less than 2.0 K Ohms 

Operating Temperature 

 

14 to 113°F (-10 to 45°C)

Operating Humidity 

 

0-85%

Storage Temperature 

 

14 to 122°F (-10 to 50°C)

Dimensions 

 

4.5 x 3 x 1.1 “ (115 x 75 x 29mm)

Weight 

 

3.9oz (111g)

Operating Instructions

Remote Continuity Test

Remote continuity testing requires both the Main Unit and Remote Unit. 
This test is mainly used for verification of continuity for cable/wires, or 
identification of cable/wires. Ideally used for testing cable TV, electrical 
cables, and telephone/speaker wiring in multi-room or multi-floor  
installations. The remote continuity test mode can be used to check  
continuity and identify two, three or more cables/wires by applying simple 
logic and testing strategy.

1.   Turn on the Main Unit and the Power LED light will turn green. If 

LED light does not turn on, replace the battery.

2.   Refer to Figure 2, attach the red and black clips of the Main Unit to 

one end of cable/wires under test, then go to the other end of the 
cable/wires and connect them to the test leads of the Remote Unit.

3.   If continuity exists, the bi-color LED of the Remote Unit will flash 

either green or red depending on the Remote Unit leads orientation. 
Meanwhile the Main Unit will beep and the continuity LED will  
flash red.

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R5300

Страница 1: ...reedinstruments www com Model Instruction Manual Continuity Tester R5300 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 2: ...s operation by measuring known wires by using both local and remote continuity tests Do not use the tester if it operates abnormally Adhere to local and national safety regulations and follow normal...

Страница 3: ...Black Clip 7 Red Clip 8 Remote Unit 9 Bi Color LED 10 Continuity LED Tip To remove the Remote Unit from the Main Unit use one hand to hold the Main Unit and use other hand to move the Remote Unit upw...

Страница 4: ...ification of cable wires Ideally used for testing cable TV electrical cables and telephone speaker wiring in multi room or multi floor installations The remote continuity test mode can be used to chec...

Страница 5: ...of the Remote Unit then the bi color LED flashes green indicating correct connec tion orientation 5 If the bi color LED flashes red this indicates the Remote Unit leads are not correctly connected Re...

Страница 6: ...wo wires of the cable together 4 When continuity is found the Main Unit will beep and the continuity LED will flash red 5 To test other devices connect the Main Unit s leads to device ter minals in an...

Страница 7: ...o reedinstruments com Notes ______________________________________ ____________________________________________ ____________________________________________ ___________________________________________...

Страница 8: ..._______________________ ________________________________________________ ________________________________________________ ________________________________________________ _____________________________...

Отзывы: