Overrange Indicator 

Yes

Continuity Check 

Audible signal if resistance <10Ω

Non-Contact  
Voltage Detector 

Yes

Autoshut off 

Yes (after 15 mins)

Power Supply 

2 AAA Batteries

Low Battery Indicator 

Yes

Jaw Opening 

0.67” (17mm)

Overvoltage Category 

CAT. II 600V, CAT. III 300V

Product Certifications 

CE, ETL, RoHS

Operating Temperature 

32 to 104°F (0 to 40°C)

Storage Temperature 

14 to 122°F (-10 to 50°C)

Dimensions 

6.9x 2.4 x 1.3” (175 x 60 x 33.5 mm)

Weight 

6oz (170g)

Overload protection: 100A

• Accuracy guarantee scale: 5~100% of measuring range, <20 digit 

residual reading is allowed for 600mA open circuit.

• AC crest factor may reach 3.0 at 4,000 counts; for non-sinusoidal 

waveform, the error of crest factor increases with the following formula:

a.  Add 3% when the crest factor is 1~2
b.  Add 5% when the crest factor is 2~2.5
c.  Add 7% when the crest factor is 2.5~3
Overload protection: 600V-PTC

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание R5015

Страница 1: ...reedinstruments www com Model Instruction Manual INSTRUMENTS INSTRUMENTS True RMSmA Clamp Meter R5015 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...caused by arc discharge when the live conductor is exposed Before each use check the product carefully to ensure no damage Hold the instrument by the handle when in use Before changing the battery en...

Страница 3: ...ry and over range indicators Diode test and continuity check functions Durable double molded plastic housing Cat II 600V CAT III 300V safety rating Auto shut off Includes test leads batteries and carr...

Страница 4: ...0k 0 8 rdg 2 dgt 6M 1 2 rdg 3 dgt 60M 1 5 rdg 5 dgt Resolution 1pF 10pF 100pF 1nF 10nF 100nF 1 F 10 F Capacitance Range 6 2nF 62nF 620nF 6 2 F 62 F 620 F 6 2mF 62mF Accuracy 6 200nF 4 10 62 00nF 620 0...

Страница 5: ...Temperature 14 to 122 F 10 to 50 C Dimensions 6 9x 2 4 x 1 3 175 x 60 x 33 5 mm Weight 6oz 170g Overload protection 100A Accuracy guarantee scale 5 100 of measuring range 20 digit residual reading is...

Страница 6: ...from ACV DCV Hz Resistance Diode Capacity Current ACA DCA NCV Off 5 HOLD Backlight Button To keep the current measurement on the screen Hold button for 2 seconds for backlight to turn on 6 ZERO Butto...

Страница 7: ...reedinstruments www com 7 INSTRUMENTS INSTRUMENTS LCD Description www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 8: ...d 600V AC DC as there is a risk of electric shock and potential damage to the instrument that may occur Measure Resistance Diode Circuit On Off Capacity Insert the red probe in the red jack positive t...

Страница 9: ...000mA 60A Press the ZERO button to bring the reading back to zero Press it multiple times if pressing it once doesn t work Open the clamp head and attach the wire on the hook Ensure that the hooks are...

Страница 10: ...HOLD button for 2 seconds to turn on the LCD backlight Automatically Turns Off If the unit is left unused for 15 minutes it will automatically turn off to save power Press the SELECT button in shutdo...

Страница 11: ...600V mA AC DC current 620mA or 6200mA A AC DC large current 62A Battery Replacement 1 Ensure the power switch is set to OFF and pull the probe out of input jack 2 Remove the battery cover with a screw...

Страница 12: ...__________________________________ ________________________________________________ ________________________________________________ ________________________________________________ __________________...

Отзывы: