REED R2002 Скачать руководство пользователя страница 3

reedinstruments

www

com

3

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

Safety

• 

Do not let the laser beam enter your eye, another person’s eye or the 
eye of an animal

• 

Do not shine the laser beam off of a reflective surface into your eye

• 

Do not direct the laser beam towards any gas that can explode 

Features

• 

Precise non-contact temperature measurements

• 

Built-in laser pointer identifies target area

• 

8:1 Distance to Spot Size ratio

• 

Fixed emissivity covers 90% of all applications

• 

Automatic ambient temperature compensation

• 

Max/Min temperature display

• 

User selectable °F or °C

• 

Display backlight

• 

Automatic Data hold

• 

Trigger lock

• 

Low battery indication with auto shut off 

 
 
 
 
 
 
 
 

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R2002

Страница 1: ...Model R2002 Infrared Thermometer Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123Yellow 0 27 100 REED Instruments 1 877 849 2127 info reedinstruments com...

Страница 2: ...nly if you REALLY need them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Table of Contents Safety 3 Features 3 Specifications 4 Instrument Description 5 Operating Instructions 6 7 Battery...

Страница 3: ...ye of an animal Do not shine the laser beam off of a reflective surface into your eye Do not direct the laser beam towards any gas that can explode Features Precise non contact temperature measurement...

Страница 4: ...e 1 sec Emissivity 0 95 fixed value Field of View Approx 8 1 distance to spot ratio with 90 encircled energy at focal point Diode Laser Output 1mW Wavelength 630 670nm class 2 II Laser product Spectra...

Страница 5: ...534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Instrument Description 1 IR Sensor 2 Laser Pointer 3 LCD Display 4 C F Button 5 Max Min Button 6 Laser Backlight Button 7 Trigger 8 Battery Cover Disp...

Страница 6: ...after approximately 8 seconds of inactivity Notes The meter will take up to 30 minutes to adjust from high ambient temperatures to low ambient temperatures Not recommended for measuring shiny or polis...

Страница 7: ...es from the target the diameter of the object under test must be at least 1 inch in size The target needs to be larger than the unit s spot size The smaller the target the closer you should be to it W...

Страница 8: ...______________________ ________________________________________________ ________________________________________________ ________________________________________________ ______________________________...

Отзывы: