background image

 

 
 

PES1 Safety

 

 

 

PES1IPS #04290 

PES1CTS #04292 

Safety Considerations 

Pressure control situations requiring squeeze-off may involve working in the 
vicinity of escaping gas.  Consider the possibility and potential hazard of static 
electricity and observe safety precautions.  Safety precautions regarding static 
electricity generally include performing squeeze-off in a separate bellhole remote 
from the blowing gas; applying a wet rag/tape to the pipe surface; and spraying 
the area with a fine water mist to conduct the static charge to the ground – 
grounding the squeeze-off tool*.  Check the squeeze-off tool prior to use to assure 
it is the correct size; is properly functioning; and is properly adjusted for the 
squeeze-off to be done. 

 
* Consider using Reed’s Grounding Accessory (#04619) and Static Discharge Alarm 

(#04620). 

 

 

12/02     54290 

 

Reed Manufacturing Co. 

                                                                                  Phone: 800-666-3691 or 814-452-3691 

1425 West 8

th

 St. 

                                                                                       Fax: 800-456-1697 or 814-455-1697 

Erie, PA 16502 USA                                                                                                                                                                             

www.reedmfgco.com

 

 
 

PES1 Safety

 

 

 

PES1IPS #04290 

PES1CTS #04292 

Safety Considerations 

Pressure control situations requiring squeeze-off may involve working in the 
vicinity of escaping gas.  Consider the possibility and potential hazard of static 
electricity and observe safety precautions.  Safety precautions regarding static 
electricity generally include performing squeeze-off in a separate bellhole remote 
from the blowing gas; applying a wet rag/tape to the pipe surface; and spraying 
the area with a fine water mist to conduct the static charge to the ground – 
grounding the squeeze-off tool*.  Check the squeeze-off tool prior to use to assure 
it is the correct size; is properly functioning; and is properly adjusted for the 
squeeze-off to be done. 

 
* Consider using Reed’s Grounding Accessory (#04619) and Static Discharge Alarm 

(#04620). 

 

 

12/02     54290 

 

Reed Manufacturing Co. 

                                                                                  Phone: 800-666-3691 or 814-452-3691 

1425 West 8

th

 St. 

                                                                                       Fax: 800-456-1697 or 814-455-1697 

Erie, PA 16502 USA                                                                                                                                                                             

www.reedmfgco.com

 

Отзывы: