reedinstruments
www
com
9
Pantone 534 Blue
Pantone 123 Yellow
Pantone 485 Red
Pantone 123 Yellow
Pantone 534 Blue
Black
Rich Black -
20/20/20/100
Blue - 100/80/30/5
Yellow - 0/27/100/0
Red - 10/100/100/5
Yellow - 0/27/100/0
Blue - 100/80/30/5
Only if you REALLY need them:
Pantone 534 Blue - 100/80/30/5
Pantone 485 Red - 10/100/100/5
Pantone 123 Yellow - 0/27/100/
WATT
1.. Press.the.“WATT.II.6000W”.Function.Switch
2.. Adjust.the.Watt.Zero.Adjust.Knob.until.the.display.shows.a.value..
of.“0”
3.. Connect.a.standard.power.source.and.add.a.LOAD.(as.depicted.
in.AC.Watt.Measurement).whose.value.is.near.full.scale.(600V,.
10A).and.is.known.to.within.0.5%.accuracy.
4.. Adjust.VR2.until.the.display.shows.the.proper.WATT
5.. Remove.the.standard.power.source.and.LOAD.
Battery Replacement
1.. When.“LOW.BAT”.appears.on.the.left.corner.of.LCD.screen.you.
will.need.to.replace.the.battery
2.. Loosen.the.battery.compartment.screw.and.slide.off.the.battery.
cover.off.to.remove.the.battery
3.. Replace.with.a.new.9V.battery.(006V.DC.9V).and.reinstall.the.
cover
REED Instruments
1-877-849-2127 | [email protected] | www.reedinstruments.com