background image

Digital 

Refractometer

Instruction 

Manual

R9510

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R9510

Страница 1: ...Digital Refractometer Instruction Manual R9510 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 2: ...Battery 7 Error Codes 8 Applications 8 Accessories and Replacement Parts 8 Product Care 8 Product Warranty 9 Product Disposal and Recycling 9 Product Support 9 Introduction Thank you for purchasing your REED R9510 Digital Refractometer Please read the following instructions carefully before using your instrument By following the steps outlined in this manual your meter will provide years of reliab...

Страница 3: ... C The prism must be cleaned thoroughly with a soft clean damp cloth after each use failure to do so will result in inaccurate readings and possible long term damage Do not drop or use excessive force as it may result in damage to the meter Do not scratch the prism surface Do not leave the instrument in a location exposed to direct sunlight or near a heat source for an extended period of time Do n...

Страница 4: ...ix 0 2 Temperature 1 F 1 C Temperature Compensation Range 50 to 104 F 10 to 40 C Sample Volume 0 3mL Measurement Time 3 seconds Auto Shut off 2 minutes Power Supply 750mAh rechargeable Li ion battery Battery Life 40 hours Charge Time 3 5 hours Product Certifications CE IP54 Dimensions 5 5 x 2 2 x 1 38 140 x 55 x 35mm Weight 0 19lbs 84g REED Instruments 1 877 849 2127 info reedinstruments com www r...

Страница 5: ...tive Cover 5 START Button 6 Sample Well 7 USB Interface Display Description 1 Battery Status Indicator 2 Temperature Measurement Reading 3 Brix Measurement Mode Indicator 4 Brix Measurement Reading REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 6: ...ection 1 Apply distilled water minimum of 0 3ml to the sample well as shown below 2 When ready close the protective cover and press the ZERO button twice to enter zero calibration mode 3 A series of dashes will appear on the display followed by 0 0 Brix which confirms that the zero calibration was successful 4 The R9510 is now ready to use Measuring Procedure 1 Inspect the sample well to be sure t...

Страница 7: ...tery life the meter is programmed to turn off after approximately 2 minutes of inactivity Sample Well Maintenance Cleaning of the sample well should be performed immediately after each sample reading Never immerse the meter in any liquid When the sample well has been completely cleaned no residue should be present To properly clean the sample well use Isopropyl Alcohol followed by a distilled wate...

Страница 8: ...d Replacement Parts CA 52A Soft Carrying Case Don t see your part listed here For a complete list of all accessories and replacement parts visit your product page on www REEDInstruments com Product Care To keep your instrument in good working order we recommend the following Store your product in a clean dry place Charge the battery as needed Clean your product with biodegradable cleaner Do not sp...

Страница 9: ... or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposing or recycling your instrument Your product contains electronic components and must be disposed of separately from standard waste products Product Support If you have any questions on your prod...

Страница 10: ...www REEDInstruments com TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Отзывы: