Product Quality

This product has been manufactured in an ISO9001 facility and has been 
calibrated during the manufacturing process to meet stated product 
specifications. If a certificate of calibration is required please contact the 
nearest authorized REED distributor or authorized Service Center. Please 
note an additional fee for this service will apply.

Safety

Never attempt to repair or modify your instrument. Dismantling your 
product, other than for the purpose of replacing batteries, may cause 
damage that will not be covered under the manufacturer's warranty. 
Servicing should only be provided by an authorized service center.

Features

•  Noise Dosimeter, Sound Level Meter and Data Logger
•  High accuracy of ±1.0dB meets Type 2 standards
•  Designed to meet noise survey requirements in compliance with OSHA 

and CCOHS regulations

•  Personal sound exposure meets IEC 61252, ANSI S1.25
•  A & C frequency weighting
•  Fast & Slow time weighting
•  Lightweight and compact design 
•  Adjustable Criterion Level, Exchange Rate and Threshold
•  USB interface with Windows

®

 compatible software to retrieve stored 

data (sold separately)

•  Easy-to-read backlit LCD display
•  Data hold and Min/Max hold
•  Tripod mount for long-term monitoring
•  Low battery indicator and auto shut off

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание R8085

Страница 1: ...Noise Dosimeter Instruction Manual R8085 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...Mode 10 Data Hold 11 Recording Maximum and Minimum Readings 11 Backlighting 11 What is Dose Noise Exposure 11 15 Noise Exposure DOSE Test Duration Mode 12 13 Noise Exposure DOSE Programmable Time Mod...

Страница 3: ...Appendix B Canada Regulations Occupational Health and Safety Regulations Occupational Exposure Limits 23 Appendix C Noise Exposure Limits by Canadian Jurisdiction 24 Appendix D Regulations Conversion...

Страница 4: ...anty Servicing should only be provided by an authorized service center Features Noise Dosimeter Sound Level Meter and Data Logger High accuracy of 1 0dB meets Type 2 standards Designed to meet noise s...

Страница 5: ...Resolution 0 1dB Response Time Approx 1 second Frequency Range 31 5Hz to 8kHz Frequency Weighting A C Time Weighting Fast Slow 125mS and 1 second Microphone 0 5 12 7mm electret condenser Display 4 di...

Страница 6: ...oftware R8085 PC optional Software OS Compatability Windows XP Vista 7 8 10 Product Certifications CE IEC61252 ANSI S1 25 for Noise Dose and Sound Exposure Meters IEC 61672 Class 2 ANSI S1 4 Type S fo...

Страница 7: ...dB 500 3 2dB 0dB 1 5dB 1K 0dB 0dB 1 0dB 2K 1 2dB 0 2dB 2 0dB 4K 1dB 0 8dB 3 0dB 8K 1 1dB 3dB 5 0dB Time Weightings Fast Slow Characteristics Time Weighting Characteristics Max Response Reference conti...

Страница 8: ...n 4 Up Duration Begin Fast Slow dB Range Button 5 FUNCTION SET Button 6 Microphone Input Jack 7 RUN PAUSE Button 8 Down A C TIME Check Button 9 ENTER LOG Button 10 Wrist Strap Anchoring Point 11 RS 23...

Страница 9: ...Weighting Indicator 8 Recording Status Indicator 9 DOSE Measurement Sound Pressure Level SPL 1 dB Range Indicator 2 Time Weighting Indicator 3 Unit of Measure 4 Frequency Weighting Indicator 5 Sound...

Страница 10: ...the measurement of Peak Sound Pressure Level If the C Weighted level is much higher than the A Weighted level then there will be a large amount of low frequency noise 4 Press the button to scroll thr...

Страница 11: ...e When in recording mode the POWER button is disabled and the meter cannot be turned off Backlighting Press the BACKLIGHT button to turn the LCD Backlight on It will automatically turn off after appro...

Страница 12: ...d the button to select the desired Response Time 3 Set the Criterion Level Lc Exchange Rate ER and Threshold Level Lt see Setup Mode section for details Note At start up the meter s default settings a...

Страница 13: ...xposure value is displayed 15 To erase the previous accumulated DOSE value and start a new duration test press the FUNC and ENTER buttons simultaneously 16 Press the FUNC button to resume normal opera...

Страница 14: ...be placed in a pant or shirt pocket 16 Clip the microphone as close as possible to the user s ear i e shirt collar Note Set the cable in a way that does not hinder the user s ability to perform their...

Страница 15: ...c Data Logging Setup the meter parameters in order to automatically log data into the internal memory Note The meter can store up to 16 000 data points and will indicate FULL on the LCD display when t...

Страница 16: ...logging session press the LOG button and LOGGER will stop flashing 4 To resume press the LOG button again 5 To end the current data logging session press and hold the LOG button for 2 seconds to resu...

Страница 17: ...rnal clock will keep accurate time when the meter is powered off When new batteries are installed the clock will have to be reset Setting the Data Logging Sampling Rate SP t Follow steps 1 and 2 when...

Страница 18: ...low steps 1 and 2 when SEt LT appears on the LCD 1 Use the and buttons to adjust the threshold which can be set anywhere between 70 and 90 dB 2 Press the ENTER button to confirm selection and skip to...

Страница 19: ...and Sampling Rate During normal operation press the TIME button to display the year month day hour minutes and selected sampling rate Calibration Procedure In order to calibrate the R8085 an external...

Страница 20: ...into the memory which will flash confirming it has been saved 12 Press the FUNC button to exit the calibration mode and resume normal operation Data Stream Output Using Terminal application a data st...

Страница 21: ...3 x AAA batteries 4 Secure the battery cover and tighten the screw Applications Personal Accumulated Noise Exposure Preventative Maintenance Industrial Machinery Equipment Construction Sites Ensuring...

Страница 22: ...cement parts visit your product page on www reedinstruments com Appendix A USA Regulations OSHA Regulation Conversion Charts OSHA Permissible Noise Exposures Duration per day hours Sound level dBA slo...

Страница 23: ...Rate Allowable Level dB A Allowable Level dB A 90 8 90 93 4 95 96 2 100 99 1 105 102 0 5 110 105 0 25 115 Table 1B Noise Exposure Limits when Criterion Level 85 dB A 3 dB A Exchange Rate Maximum Perm...

Страница 24: ...85 3 Northwest Territories 85 Nunavut 85 Yukon Territories 85 3 In Nunavut and Northwest Territories the Occupational Health and Safety Regulations reference a staged action plan based on the dBA exp...

Страница 25: ...91 3 65 86 9 125 91 6 Note 5 dB exchange rate and 90 dBA Criterion Product Care To keep your instrument in good working order we recommend the following Store your product in a clean dry place Change...

Страница 26: ...r by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when dis...

Страница 27: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 28: ...www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Отзывы: