background image

3

www.REEDIN STRUM EN TS.com

Int r oduct ion

Thank you for purchasing your REED R2310 Infrared Thermometer. Please 
read the following instructions carefully before using your instrument. By 
following the steps outlined in this manual your meter will provide years of 
reliable service.

Pr oduct   Qualit y

This product has been manufactured in an ISO9001 facility and has been 
calibrated during the manufacturing process to meet stated product 
speci cations. If a certi cate of calibration is required please contact the 
nearest authorized REED distributor or authorized Service Center. Please 
note an additional fee for this service will apply.

Safet y

• Never attempt to repair or modify your

instrument. Dismantling your product, 
other than for the purpose of replacing 
batteries, may cause damage that will 
not be covered under the manufacturer’s 
warranty. Servicing should only be 
provided by an authorized service center.

• Use extreme caution when the laser beam

is turned on.

• Do not let the beam enter your eye, another person's eye or the eye of

an animal.

• Be careful not to point the beam off a reáective surface and strike your eye.
• Do not allow the laser light beam to impinge on any gas which can explode.

 

REED Inst r ument s

1 -8 7 7 -8 4 9 -2 1 2 7  | info@r eedinst r ument s.com | www.r eedinst r ument s.com

Содержание R2310

Страница 1: ...www REEDINSTRUM ENTS com In r ar d Th r mom t r In t r ct ion M an al R2 3 1 0 REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 2: ...aximum Minimum Average and Differential Functions 10 Setting the High Temperature Alarm 10 Setting the Low Temperature Alarm 11 Adjusting Emissivity 11 Switching the Unit of Measure F C 12 Turning Laser ON OFF 12 Trigger Lock Setup 12 Turning High and Low Alarms ON OFF 13 Battery Replacement 14 Applications 14 Appendix Emissivity Chart 15 16 Product Care 17 Product Warranty 17 Product Disposal and...

Страница 3: ...ributor or authorized Service Center Please note an additional fee for this service will apply Safety Never attempt to repair or modify your instrument Dismantling your product other than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an authorized service center Use extreme caution when the la...

Страница 4: ...tion and auto shut off Included Carrying Case Battery Specifications Temperature Range 31 to 1202 F 35 to 650 C Accuracy 32 F 0 C 3 6 F 1 8 C or 1 8 rdg whichever is greater 32 F 0 C 3 6 F 0 1 F 1 8 C 0 1 C rdg Resolution 0 1 F 0 1 C Optical Resolution D S 12 1 Spectral Response 8 to 14µm Emissivity 0 1 to 1 0 Adjustable Response Time 250ms Backlit Display Yes Display Hold Yes High Low Alarms Yes ...

Страница 5: ...rox 10 hours with continuous use backlight on Product Certi cations CE RoHS IP65 Drop Tested Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 4 to 140 F 20 to 60 C Operating Humidity Range 10 to 90 Maximum Operating Altitude 6561 2000m Maximum Storage Altitude 39370 12000m Dimensions 7 4 x 4 7 x 2 2 189 x 118 x 55mm Weight 10 3oz 292g REED Inst r ument s 1 877 849 2127 info reedinst...

Страница 6: ...High Low Alarm Indicators 5 LCD Display 6 Mode Button Down Arrow 4 5 6 7 8 9 12 10 11 1 2 3 7 Set Button 8 High Low Alarm Button Up Arrow 9 Handle Grip 10 Battery Cover 11 Battery Compartment Screw 12 Tripod Mount REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 7: ...ON High and Low Limit Alarm Low Battery Temperature Measurement Active Measurement Data Hold Unit of Measurement Temperature Measurement Value Mode Emissivity Temperature Measurement Value from Selected Mode REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 8: ...8 www REEDINSTRUM ENTS com Distance Spot Size REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 9: ...rement has stopped and the last measured temperature will remain on screen until another measurement is taken or the unit turns off Continuous Temperature M easurement Trigger Lock 1 Once the trigger lock function is enabled see page 12 the icon will appear on the display and the icon will áash when the trigger is pressed The thermometer will continuously measure temperature and the backlight will...

Страница 10: ... Setting the High Temperature Alarm Press the SET button once to enter the high alarm limit setup Use the UP and DOWN buttons to set temperature value Press the UP and DOWN buttons to add or subtract 1 Hold the UP or DOWN buttons to add or subtract 10 temperature values The instrument will exit the setup after 5 seconds of inactivity continued REED Inst r ument s 1 877 849 2127 info reedinstrument...

Страница 11: ...t will exit the setup after 5 seconds of inactivity Adjusting Emissivity The instrument s emissivity can be adjusted from 0 01 to 1 0 Press the SET button three times to enter the emissivity setup Use the UP and DOWN buttons to set the values Press the UP and DOWN buttons to add or subtract 0 01 unit and or hold the UP and DOWN buttons to add or subtract 0 1 The thermometer will exit the setup aft...

Страница 12: ... press the SET button ve times to enter laser setup Use the UP and DOWN buttons to turn the laser on or off The thermometer will exit the setup after 5 seconds of inactivity Trigger Lock Setup To turn the lock measurement on or off press the SET button six times to enter lock measurement setup Use the UP and DOWN buttons to feature on or off The thermometer will exit the setup after 5 seconds of i...

Страница 13: ... Press the button to enter alarm setup screen Press the button again to toggle through the alarm functions 1 High Low alarms on 2 High alarm on 3 Low alarm on 4 No alarm set 1 3 2 4 REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 14: ...ighten the screw Applications Verify mechanical bearings motors or electrical circuit breaker boxes equipment Calibration and control of heater and oven temperatures Monitoring materials in processes involving heating and or cooling Quality control monitoring Research and development applications Automotive diagnostics Conduct HVAC energy audits REED Inst r ument s 1 877 849 2127 info reedinstrume...

Страница 15: ...it Measure the temperature of the tape or painted surface Measured Surfaces Emissivity Metal Aluminum Oxidization 0 2 0 4 A3003 Alloy Oxidization Rough 0 3 0 1 0 3 Brass Burnishing Oxidization 0 3 0 5 Copper Oxidization Electric Temrinal Board 0 4 0 8 0 6 Hastelloy Alloy 0 3 0 8 Inconel Oxidization Sand Blasting Electro Burnishing 0 7 0 95 0 3 0 6 0 15 Iron Oxidization Rusting 0 5 0 9 0 5 0 7 Iron...

Страница 16: ...lt 0 7 Carbon Non Oxidization Graphite Silicone Carbide 0 8 0 9 0 7 0 8 0 9 Ceramics 0 95 Clay 0 95 Concrete 0 95 Cloth 0 9 Glass Convex Smooth Lead Boron 0 76 0 8 0 92 0 94 0 78 0 82 Plates 0 96 Stone Products 0 93 Plaster 0 8 0 95 Ice 0 98 Limestone 0 98 Paper 0 95 Plastics 0 95 Water 0 93 Soil 0 9 0 98 Wood 0 9 0 95 REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments...

Страница 17: ...oves to be defective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instruments shall not be liable for damages to goods property or persons due to improper use or through attempts to utilize the instrument under conditions which exceed the designed capabilities In order to begin ...

Страница 18: ...eedinstruments com Please visit www REEDINSTRUM ENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is strictly prohibited without prior written permission from REED Instruments REED Inst r ument s 1 877 849 2127 info reedinstruments com ww...

Страница 19: ...www REEDINSTRUM ENTS com Tes T M ea s u r e w iTh Co n f id en Ce Ch eCk o u T o u r l aTes T Pr o d u CTs REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 20: ...2 0 www REEDINSTRUM ENTS com AIR VELOCITY TEM PERATURE HUM IDITY SOUND M OISTURE ELECTRICAL www REEDINSTRUM ENTS com REED Inst r ument s 1 877 849 2127 info reedinstruments com www reedinstruments com ...