Reed Instruments R2160 Скачать руководство пользователя страница 15

15

Enabling/ Disabling Temper at ur e Bar

1.  Press the 

SET

 button when "Temp Bar" is highlighted to enter the 

appropriate function.

2.  Press the 

 and 

 buttons to select between ON or OFF.

3.  Press the 

SET

 

button to con

fi

rm 

selection.

4.  Press the 

 

button to exit 

the "Temperature 

Bar" function 

and return to 

advanced settings.

Set t ing t he High/ Low Alar m Values

1.  Press the 

SET

 button when "HI/LO Alert" is 

highlighted to enter the appropriate function.

2.  Press the 

 and 

 buttons to select the 

parameter to be adjusted.

3.  Press the 

SET

 button to con

fi

rm selection.

4.  Use the 

 and 

 buttons to increase or 

decrease the alarm values.

5.  Press the 

SET

 button to con

fi

rm selection.

6.  Repeat steps 2 through 5 for each parameter.
7.  Press the 

 button to exit the "High/Low 

Alarms" function and return to advanced settings.

Device Infor mat ion

1.  Press the 

SET

 button when "Device Info" is 

highlighted to view detailed information of 
the device.

2.  Press the 

 button to exit the "Device Info" 

function and return to advanced settings.

continued...

 

REED Ins t r ume nt s

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R2160

Страница 1: ...Ther mal I magi ng Camer a I nst r uct i on Manual R2160 REED Ins t r ume nt s 1 877 849 2127 i nf o r eedi nst r ument s com www r eedi nst r ument s com ...

Страница 2: ...ow Temper at ur e Tr acki ng 11 Cent erPoi ntTr acki ng 11 Col orPal et t e Sel ect i on 12 Enabl i ng Di sabl i ng Hi gh and Low Temper at ur e Al ar ms 12 Syst em Set t i ngs 12 16 Set t i ng t he Language 13 Set t i ng t he Dat e and Dat e For mat 13 Adj ust i ng Emi ssi vi t y 14 Enabl i ng Di sabl i ng Aut o PowerOFF 14 Set t i ng t he LCD Br i ght ness 14 Enabl i ng Di sabl i ng Temper at ur...

Страница 3: ...t at ed pr oduct speci ficat i ons I fa cer t i ficat e ofcal i br at i on i s r equi r ed pl ease cont actt he near estaut hor i zed REED di st r i but ororaut hor i zed Ser vi ce Cent er Pl ease not e an addi t i onalf ee f ort hi s ser vi ce wi l lappl y Sa fe ty Neverat t emptt o r epai rormodi f y youri nst r ument Di smant l i ng your pr oduct ot hert han f ort he pur pose ofr epl aci ng bat...

Страница 4: ...t e t emper at ur e measur ement i ti s notr ecommended t o t ake measur ement s dur i ng orr i ghtaf t erchar gi ng t he i nst r ument The i nher entt emper at ur e dr i f toft he sensormay occasi onal l y cause i naccur at e measur ement s I n t hi s case pr ess t he but t on undert he t emper at ur e measur ementi nt er f ace t o Cal i br at e t he sensor F e a tu re s 160 x 120 i nf r ar ed r ...

Страница 5: ...Resol ut i on 0 1 F C Detector Speci cations Det ect orType Uncool ed mi cr obol omet er Focalpl ane ar r ay FPA Spect r alRange 8 t o 14μm I R Resol ut i on 160 x 120 19 200 pi xel s Image Presentation and Measurement Analysis Di spl ay 2 8 col orTFT Col orPal et t es 5 I r on Rai nbow Gr ay Red Whi t e Whi t e Bl ue Cent erSpot Yes Emi ssi vi t y Adj ust abl e 0 01 t o 0 99 Temper at ur e Al ar ...

Страница 6: ...4 hour s PC Connect i vi t y USB Cabl e Type C Sof t war e Yes downl oad f r om websi t e Sof t war e OS Compat i bi l i t y Wi ndows 7 8 10 Suppor t ed Languages Engl i sh and Fr ench Pr oductCer t i ficat i ons CE I P65 6 5 2m dr op t est Oper at i ng Temper at ur e 32 t o 122 F 0 t o 50 C St or age Temper at ur e 4 t o 140 F 20 t o 60 C Oper at i ng St or age Humi di t y Range 10 t o 90 Maxi mu...

Страница 7: ...r f ace 6 I nf r ar ed Camer a Lens 7 I nt er f ace Cover 8 LCD Di spl ay 9 POWER But t on 10 Li ghtBut t on 11 LEFT But t on 12 SET But t on 13 UP But t on 14 Pl ayback But t on 15 BACK But t on 16 RI GHT But t on 17 DOWN But t on 18 Tr i pod Mount i ng Hol e REED Ins t r ume nt s 1 877 849 2127 i nf o r eedi nst r ument s com www r eedi nst r ument s com ...

Страница 8: ...l et t e Set t i ngs 7 Hi gh Low Temper at ur e Al ar m Set t i ngs Power ON OFF Pr ess and hol d t he POWER but t on f or3 seconds t o poweron To t ur n OFF pr ess t he POWER but t on f or1 second 8 Advanced Menu Set t i ngs 9 Mi ni mum SpotTemper at ur e 10 Cent erSpot 11 Maxi mum SpotTemper at ur e 12 Bat t er y I ndi cat or 13 Dat e Ti me REED Ins t r ume nt s 1 877 849 2127 i nf o r eedi nst ...

Страница 9: ...stofemi ssi vi t y val ues f orsome common mat er i al s The f ol l owi ng t abl e gi ves t ypi calemi ssi vi t y ofsome mat er i al s Mat er i al Emi ssi vi t y Asphal t 0 95 Concr et e 0 95 Har d pl ast er 0 90 Wood nat ur al 0 93 Li me St one 0 98 Bal l astchi ppi ng 0 95 Paper ever y col or 0 95 Pl ast i cs non fil m 0 95 Ti ssue f abr i c 0 95 Sand 0 90 Gl ass wool 0 90 Mel t ed asphal t 0 93...

Страница 10: ...ed di st r i but ororCust omerSer vi ce ati nf o r eedi nst r ument s com or1 877 849 2127 Op e ra tin g In s tru c tio n s M ain M enu 1 Pr ess t he SET but t on t o ent ert he mai n menu 2 Use t he and but t ons t o scr ol lt hr ough t he l i stofpar amet er s Swi t chi ng t he Uni tofMeasur e F C Enabl i ng Di sabl i ng Cent erPoi nt Hi gh Low Temper at ur e Spot s Col orPal et t e Sel ect i on...

Страница 11: ... ess t he SET but t on when t he t emper at ur e uni tofmeasur e submenu i s sel ect ed 2 Use t he and but t ons t o swi t ch bet ween or 3 Forcent erpoi nt pr ess t he SET but t on when i s hi ghl i ght ed t o enabl e ordi sabl e t hi s f eat ur e 4 Fort emper at ur e t r acki ng pr ess t he SET but t on when i s hi ghl i ght ed t o enabl e ordi sabl e t hi s f eat ur e 5 Pr ess t he SET but t on...

Страница 12: ...ct ed 2 Use t he and but t ons t o enabl e or di sabl e hi gh orl ow al ar m Note Each al ar m can be enabl ed di sabl ed separ at el y 3 Pr ess t he SET but t on t o save yoursel ect i on and r et ur n t o t he mai n menu 4 Pr ess t he SET but t on agai n t o exi tt he mai n menu and r esume nor maloper at i on Advanced Settings M enu 1 Whi l e i n t he mai n menu scr een pr ess t he SET but t on...

Страница 13: ...but t on when Dat e Ti me i s hi ghl i ght ed t o ent ert he appr opr i at e f unct i on 2 Use t he and but t ons t o sel ectt he par amet ert o be adj ust ed 3 Pr ess t he SET but t on f ol l owed by t he and but t ons t o adj ust t he sel ect ed par amet er 4 Pr ess t he SET but t on agai n t o confir m sel ect i on 5 Repeatst eps 2 t hr ough 4 f oreach r equi r ed par amet er 6 Pr ess t he but ...

Страница 14: ...i on 2 Pr ess t he and but t ons t o sel ectt he desi r ed Aut o PowerOf fopt i on bet ween Of f 5 Mi n 10 Mi n or 30 Mi n 3 Pr ess t he SET but t on t o confir m sel ect i on 4 Pr ess t he but t on t o exi tt he Aut o Power Of f f unct i on and r et ur n t o advanced set t i ngs Setting the LCD Brightness 1 Pr ess t he SET but t on when Br i ght ness i s hi ghl i ght ed t o ent ert he appr opr i ...

Страница 15: ...t o sel ectt he par amet ert o be adj ust ed 3 Pr ess t he SET but t on t o confir m sel ect i on 4 Use t he and but t ons t o i ncr ease or decr ease t he al ar m val ues 5 Pr ess t he SET but t on t o confir m sel ect i on 6 Repeatst eps 2 t hr ough 5 f oreach par amet er 7 Pr ess t he but t on t o exi tt he Hi gh Low Al ar ms f unct i on and r et urn t o advanced set t i ngs Device Information ...

Страница 16: ... ce 2 Pr ess t he and but t ons t o sel ect bet ween Yes or No 3 Pr ess t he SET but t on t o confir m sel ect i on 4 Pr ess t he but t on t o exi tt he For mat t i ng SD Car d f unct i on and r et ur n t o advanced set t i ngs Enabling Disabling Auto Save 1 Pr ess t he SET but t on when Aut o Save i s hi ghl i ght ed t o vi ew det ai l ed i nf or mat i on of t he devi ce 2 Pr ess t he and but t o...

Страница 17: ... Pr ess t he but t on t o r et ur n t o t he saved pi ct ur es menu 9 I f Del et e an I mage i s sel ect ed use t he and but t ons t o sel ectbet ween Yes or No as shown i n Fi gur e B 10 Pr ess t he SET but t on t o confir m yoursel ect i on 11 Pr ess t he but t on t o exi tt he saved pi ct ur es menu and r esume nor maloper at i on Ch a rg in g th e Ba tte ry 1 Connectt he R2160 vi a t he i ncl ...

Страница 18: ... r umentt o be f r ee ofdef ect s i n mat er i alorwor kmanshi p f ora per i od ofone 1 yearf r om dat e ofshi pment Dur i ng t he war r ant y per i od REED I nst r ument s wi l lr epai rorr epl ace atno char ge pr oduct s orpar t s ofa pr oductt hatpr oves t o be def ect i ve because ofi mpr opermat er i alorwor kmanshi p undernor maluse and mai nt enance REED I nst r ument s t ot all i abi l i t...

Страница 19: ...or i zed REED di st r i but ororREED I nst r ument s Cust omerSer vi ce by phone at 1 877 849 2127 orby emai lati nf o r eedi nst r ument s com Please visit www RE E DIn s tru me n ts c o m for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unauthorized copying or reproduction of this manual is stri...

Страница 20: ...TEST MEASURE WI TH CONFI DENCE CHECK OUT OUR LATEST PRODUCTS REED Ins t r ume nt s 1 877 849 2127 i nf o r eedi nst r ument s com www r eedi nst r ument s com ...

Отзывы: