background image

7

Battery Replacement

When the low battery icon appears on the left corner of LCD display, you 
will need to replace the battery. Remove the battery cover using a Phillips 
head screwdriver, insert a new 9V battery and secure the cover.

Accessories and Replacement Parts 

CA-52A

 Soft Carrying Case

Don't see your part listed here? For a complete list of all accessories and 
replacement parts visit your product page on www.reedinstruments.com.

Applications

•  HVAC and Refrigeration Servicing
•  Detecting Filter Blockage
•  Condensers and Chillers

Product Care

To keep your instrument in good working order we recommend the following:
•  Store your product in a clean, dry place.
•  Change the battery as needed. 
•  If your instrument isn't being used for a period of one month or longer 

please remove the battery.

•  Clean your product and accessories with biodegradable cleaner. Do not 

spray the cleaner directly on the instrument. Use on external parts only.

www.

.com

[email protected]

1.800.561.8187

Содержание LM-81AM

Страница 1: ...Vane Anemometer Instruction Manual LM 81AM www com information itm com 1 800 561 8187 ...

Страница 2: ...asing your REED LM 81AM Vane Anemometer Please read the following instructions carefully before using your instrument By following the steps outlined in this manual your meter will provide years of reliable service Product Quality This product has been manufactured in an ISO 9001 facility and has been calibrated during the manufacturing process to meet stated product specifications If a certificat...

Страница 3: ...red under the manufacturer s warranty Servicing should only be provided by an authorized service center Features Measures fpm m s kph mph and knots Easy to operate compact design 4 digit LCD display Min Max and data hold functions Designed for one hand operation Low battery indicator and auto shut off Included Wrist Strap Battery www com information itm com 1 800 561 8187 ...

Страница 4: ...1 Vane Diameter 1 3 32mm Response Time 1 second Display 4 digit LCD Data Hold Yes Min Yes Max Yes Sampling Rate 1 time second Auto Shut Off Yes after 10 minutes Low Battery Indicator Yes Power Supply 9V Battery Product Certifications CE Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 14 to 140 F 10 to 60 C Operating Humidity Range 10 to 80 Dimensions 6 1 x 2 4 x 1 3 156 x 60 x 33mm...

Страница 5: ...nt Description 1 Air Flow Sensor 2 LCD Display 3 Power Button 4 Unit Button 3 4 5 6 7 8 LM 81AM 5 Wrist Strap 6 Battery Compartment Cover 7 Hold Button 8 MAX MIN Button www com information itm com 1 800 561 8187 ...

Страница 6: ...ear on the LCD 3 Press the button again to resume normal operation Recording Maximum and Minimum Readings 1 Press the MAX MIN button to enter recording mode as indicated by REC on the LCD The meter will now begin recording maximum and minimum readings 2 While in recording mode A Press the MAX MIN button once and the maximum value will appear on the display as indicated by REC MAX B Press the MAX M...

Страница 7: ... visit your product page on www reedinstruments com Applications HVAC and Refrigeration Servicing Detecting Filter Blockage Condensers and Chillers Product Care To keep your instrument in good working order we recommend the following Store your product in a clean dry place Change the battery as needed If your instrument isn t being used for a period of one month or longer please remove the battery...

Страница 8: ...e at 1 877 849 2127 or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposing or recycling your instrument Your product contains electronic components and must be disposed of separately from standard waste products Product Support If you have any que...

Страница 9: ...www com information itm com 1 800 561 8187 ...

Страница 10: ...Test Measure with Confidence Check out our latest Products www com information itm com 1 800 561 8187 ...

Отзывы: