Installation

Grounding  Connection

RS485  Installation

1

3

5

2

4

5

Locating Plate

Expansion Bolts

6

Locating Plate

Nut / washer

Stand

4

Avoid water and electricity when drilling, bit size φ8mm, drilling depth 40mm.

This figure is for reference only, please refer to the actual product!

Customers could connect their own WiFi

module,to replace the built-in WiFi module

with the same communication port.
Refer to the RX - 2505AC manual for the

detail of the RS485 installtion.

Notice

RX-2505AC 

Bracket

1

2

3

4

2

3

1

1

+5V

485

A

GND

2

3

4

-

485

B

-

CT or smartmeter Installation (choose one of them)

1

2

4

6

5

3

RX-2505AC

Mark

Mark

4Pin

Connector

RX-2505AC

4Pin

Connector

Nut

CT_GRID

CT_PV

Connector

CT_GRID - ( 

 )

CT_PV  - ( Black )

C ( 

 )

CT_PV + (   )  

Waterproof Sealing Ring 

Nut

4Pin Connector

M2.5

 

1 N.M

 

Screw

Notice

CT

L-Line

GRID

Load

N

1

2

N

CT_PV + 
CT_PV -

C

CT_GRID -

CT

L-Line

4Pin Connector diagram

Middle Connector diagram

1

2

CT_PV + 
CT_PV -

C

CT_GRID -

The CT with the "GRID" label is
connected to the L line of the
power grid. If there is a solar
inverter at home, you can
connect the CT with "PV" label
to the Lline of the inverter. The
"GRID" CT arrow points towards
the grid. The  "PV"  CT arrow
points from PV to power panel.