Redsail Laser
2) Water temperature should be examined at all times during the working
process. Once the water turns to be warm, please change it right away (the right way of
changing the water is to get out of some hot water and fill in cold water).
3) If there is any particular requirements, the Current shouldn't be no more than
20MA, thus to avoid the tube becoming aged quickly.
4) Water tank, water pump and water inlet rubber tube should be cleaned once
every week.
5) Lens and mirrors should be cleaned once every day before starting the
machine (Notice: not at the time of being off duty).
6) Don't clean the reflecting mirror carefully when it is on the machine, otherwise,
the ray path must be readjusted!
7) When cleaning the 4
th
reflecting mirror and condensing lens, they must be
removed form the machine. After that, the mirror and lens should be fixed firmly but not
too tightly for fear of breaking up.
8) Please pay attention to the focus length before starting the machine every time.
If the length is not accurate, it will greatly affect the engraving effects.
9) Please clean the working plate every time after working. Don't make the dust
fly upwards.
10) Guide rails should be cleaned, and lubricant should be added onto the rail
every two weeks.
11) The outer equipments (blower fan, air pump, etc.) should be cleaned once
every two weeks.
Redsail Tech Co., Ltd
http://www.hflaser.com