If the shower is unsatisfactory, make the following checks before calling out the contractor. Any 
of these adjustments could restore the performance 

 
a) Water too HOT   

Increase water flow by adjusting the 
temperature control clockwise. 
Clean spray plate holes. (Select outer or 
combination spray patterns). 
Switch power to MEDIUM setting. 
Increase pressure of water supply e.g. fully 
open service valve or stop cock. Check hose is 
not kinked restricting the water flow. 
 

 
b) Water too COLD 

Decrease water flow by adjusting the 
temperature control anti-clockwise.  
Select inner or outer spray patterns only. 

Switch power to HIGH setting. 

c) Spray pattern poor 

Clean spray plate and flush heater with 
handset removed. Select inner / outer spray 
pattern. 

 
d) Water goes cold while using shower 

Check power setting lights are on 
Check water pressure has not fallen so far as 
to let pressure switch cut out, e.g. another tap 
drawing water off. Raise position of handset

.

 

 
e) Broken parts 

Please contact our spares department on  
0870 0102 829. Fitting instructions are 
provided with spares. 

 

PROFESSIONAL SERVICE 

 

If the previous checks fail to restore the performance, you should either contact the Redring 
Technical Advisory Service or seek the assistance of a qualified plumber and / or electrician. 

 

The person who installed the shower is probably the best one to repair it and is certainly 
the person to contact if you have a problem in the guarantee period. 

 

The following additional checklist is provided for the benefit of the qualified serviceman. 

 

WARNING – SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE 
REMOVING THE COVER TO MAKE CHECKS. 

 
a) Water too HOT 

Water flow restricted by blockage in filter of 
solenoid valve. Switch off water and undo 
plastic nut on elbow, loosen brass nut to swing 
elbow away from solenoid. Remove filter in 
solenoid with long nosed pliers and flush 
clean. 

 
b) Water too COLD 

Check circuit through thermal cut-out 
Check circuit through microswitch on the 
pressure switch 
Check each element circuit. 
Check tightness of electrical connections. 

 
c) Water leaks from burst pressure relief 

valve 

Check for cause of high pressure and remove 
it. Blockage on outlet i.e. blocked spray plate. 
Replace the pressure relief disc. 

 
d) Water does not flow when button “A” 

“B” or “C is pressed 

Check the circuit through the solenoid coil. 
Check circuit through microswitch 
Possible PCB fault, if defective, then replace. 
Power supply not reaching shower. 

Содержание 650

Страница 1: ...Shower Handbook Also covers 650 chrome variant IMPORTANT Please retain this booklet for future reference ...

Страница 2: ...nts The final adjustment can be anywhere on the scale See diagram 3 for relationship of flow to temperature 5 Once a temperature setting to your liking has been achieved knob E will rarely need adjusting e g Adjust for variations of incoming mains water temperature between summer and winter 6 When you have finished showering push button D only The electricity to the elements is then disconnected a...

Страница 3: ... in the field RING 0870 9000 430 Spare parts can be supplied against any debit or credit cards RING 0870 0102 829 Remember to quote the exact type of shower as written on the front of the shower and on this leaflet It may also be of use to have a note of the model and serial number as stated on the underside the shower How your shower works Your shower is designed for convenience economy and safet...

Страница 4: ... spray plate settings adjustable by rotating the spray plate see diagram 4 The modes have a positive click to identify them If desired many combinations between the 3 can be achieved IN ORDER TO MAINTAIN THE PERFORMANCE OF YOUR SHOWER YOU MUST CLEAN THE SHOWERHEAD All water contains particles of lime which build up in the showerhead and unit reducing the performance It is therefore important to cl...

Страница 5: ...us checks fail to restore the performance you should either contact the Redring Technical Advisory Service or seek the assistance of a qualified plumber and or electrician The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have a problem in the guarantee period The following additional checklist is provided for the benefit of the...

Страница 6: ...ngement taking the following into account a The possible need to use the handset over the sink for hair washing etc b The heater must not be mounted in the direct spray from the showerhead c The handset must not be able to come into contact with any used water in the bath or basin If it can even after the hose has been retained by the hose retainer see diagram 13 then a vacuum breaker must be fitt...

Страница 7: ... the mains cold water supply This must have a minimum running pressure of 100kPa 1 0 bar 14 5 p s i and a maximum pressure of 1000kPa 10 bar 145 p s i Before connecting the pipe work to the shower ensure that pipe work is flushed out 1 It is recommended that a WRAS Water Regulations Advisory Scheme listed isolating valve is fitted between the rising main and the unit This will allow the unit to be...

Страница 8: ...current BS 7671 I E E regulations If in doubt consult a qualified electrician 1 The shower is designed for a single phase A C electrical supply Please check the rating plate on the unit to see what details apply 2 For the 9 5kW you may be able to use 6mm cable if Method 1 clipped direct is used Remember to up rate the cable if it runs in thermal insulation in a loft or for longer distance 3 A mean...

Страница 9: ...e flow valve see diagram 12 WARNING TAKE CARE WHEN REPLACING THE FRONT COVER TO AVOID DAMAGING ANY COMPONENTS 9 Operate the shower first without the handset to flush out particles fit handset and then operate the shower as explained previously and check a That the water gets to a satisfactory temperature b Power selection does give a change in water temperature c Check again for leaks d That the h...

Страница 10: ...odically cleaned as previously detailed Additional Accessories Catalogue Number White 2 metre Shower hose 83 593529 Water control tap 93 792452 Shower de scaling powder 95 711015 Curtain and rail pack 83 792802 Curtain and rail pack with non slip Bath mat 83 792801 Spares White 650 cover complete 93 597808 Plated front cover complete plated version 93 597814 Plated control knob plated version 93 5...

Страница 11: ...11 650 CHROME MODEL ACCESSORIES 11 Diagram 13 ...

Страница 12: ... details of terms and conditions are available on request from APPLIED ENERGY PRODUCTS LTD MORLEY WAY PETERBOROUGH PE2 9JJ Tel 44 0 1733 456789 Fax 44 0 1733 310606 Website www redring co uk 555 2066 01A 12 ...

Отзывы: