Page 5 of 8

Redring SB

Tank access and replacing parts

Task

Operation

Front cover removal

1. Turn power and water off

2. Drain unit via tap, be carefull of boiling water.

3. Remove the tap assy by unscrewing                 

counter-clockwise

4. Undo self-tapping screws, 2 at top and 2 at bottom 

of case. Remove the cover by drawing towards you.

Replace Solenoid

1. Directions as above in Cover Removal.

2. Disconnect wires to valve.

3. Disconnect the water fitting attached to valve.

4. Unscrew securing screws fixing valve. Remove old 

valve and replace with new valve.

5. Re-connect fitting, turn on water and check for leaks.

6. Refit case and return to operation.

Replace Element 

1. Directions as above in Cover Removal.

2. Disconnect element wiring.

3. Disconnect wiring from the manual re-set thermostat

and remove by unscrewing.

4. Remove the panel at the top of the tank, then the 3 

nuts securing the element, 2 at the bottom and 1 on 
the side of tank.

5. Remove the element through the top opening.

6. Replacement is the reverse procedure.

7. Refit case and return to operation.

NOTE: After replacing the element the top panel must 
be re- sealed to ensure water tight operation.

Replace Tap assembly

1. Directions as above in Cover Removal. Steps 1-3.

2. Re-fit the new tap assembly.

3. Ensure new thread seal tape is applied.

Replace Manual Re-Set Thermostat

1. Directions as above in Cover Removal.

2. Remove the connecting wires, unscrew the cutout.

3. Replacement is the reverse procedure.

Replace PCB.

1. Directions as above in Cover Removal.

2. Disconnect connecting wires and unscrew PCB.

3. Replacement is the reverse procedure.

4. Refit case and return to operation.

NOTE: PCB wiring is colour coded please ensure that 
the wires go back onto the same connection terminals.

All connections are 240 volt, take great care.
The temperature is non-adjustable.
PCB No.181801 is for 2.5 ltr.
PCB No.181815 is for 5ltr and larger.

Содержание 1070800E

Страница 1: ...Trouble Shooting All Models Redring SB Redring SB Professional On Wall Boiling Water Heater Models 1070800E 2 5 ltr 1070810E 5 ltr 1070815E 7 5 ltr 1070820E 10 ltr 1070825E 15 ltr 1070830E 20 ltr 1070...

Страница 2: ...and the heating cycle starts the heating will continue until the water reaches approximately 98 99 C 4 Once this temperature is reached the heating stops and filling restarts this process of heat fil...

Страница 3: ...311045 Control Board Assembly 2 5 Litre 15b 1311042 Control Board Assembly 5 to 25 Litre 16 1311058 Tap Cup Seal 17 1311060 Tap Insert 18 1310732 Tap Spring 399 0 399 0 399 0 6 2 1 8 6 2 1 8 6 2 1 8 6...

Страница 4: ...ce thermistor steam sensor No 4 page 3 2 If above does not solve problem replace PCB No 15a or 15b page 3 3 Check the thermistor is positioned correctly Manual reset thermostat Unscrew 1 Check water s...

Страница 5: ...e tank then the 3 nuts securing the element 2 at the bottom and 1 on the side of tank 5 Remove the element through the top opening 6 Replacement is the reverse procedure 7 Refit case and return to ope...

Страница 6: ...bove in Cover Removal 2 Remove PCB cover plate 3 Remove the thermistor 4 The probe end of the thermistor pushes into the condensor tube so that the tip just covers the hole drilled in the condensor tu...

Страница 7: ...Page 7 of 8 Redring SB Notes...

Страница 8: ...cts Ltd Morley Way Peterborough PE2 9JJ England General enquiry Tel 44 0 1733 456789 Fax 44 0 1733 310606 Technical Hotline Tel 44 0 8709 000430 Fax 44 0 8709 000530 Sales Spares Tel 44 0 8709 000420...

Отзывы: