Bias adjustment and bias test point

 

– Allows external access for bias adjustment (see bias 

procedure in the 

Maintenance

 section). 

 
LINE OUT

 

– A line level signal jack derived from the speaker output which contains the whole 

tone of the amplifier. 

 
Speaker Jacks

 

– The MAIN and EXT jacks are wired in parallel. The MAIN jack must be used 

first because it has a protection device. ALWAYS HAVE A SPEAKER CONNECTED TO AVOID 
PERMANENT AMPLIFIER AND OUTPUT TUBE DAMAGE. 

 
Impedance 

Selector Ω

 - Set this to the total impedance of all attached speakers.  

 

SEND and RETURN Jacks

 

– The send jack connects to the input of an external effects device 

and the return jack connects to the output of an external effects device. The return jack interrupts 
the signal path so the external effects unit must mix the wet and dry signals. 

POWER ON/OFF PROCEDURE 

1.  Check the Standby switch to make sure it is toggled downward for Standby operation.  
2.  Toggle the main power switch to the up position (this switch is located at the top of the IEC 

input module). The front panel pilot light should be lit. 

3.  Wait one minute and then toggle the Standby switch upwards to the Operate position. 
4.  POWER OFF 

– Toggle the main power switch downward, there is no need to go into 

standby first although it will not hurt anything. 

MAINTENANCE SECTION 

Your RedStar amp has been designed for years of trouble free operation. The vacuum tubes 

will need to be replaced over time. We recommend new output tubes every 160 - 240 hours and 
new preamp tubes every 320 - 480 hours. 

The front and rear panels have a protective finish that can be easily scratched with abrasives 

so always use a damp soft cloth to clean them (never use paper towels). The cabinetry can be 
cleaned with our super secret tolex cleaner (on a paper towel - 2 squirts of WD-40 and 4 squirts 
window cleaner). 

TUBE LAYOUT 

 

All tube brands are acceptable, a long plate is preferred in the V6 (Phase Inverter) position. 

 

Содержание RedStar

Страница 1: ...mplifier Designed to be Pedal Friendly PREAMP SECTION The HI GAIN Preamp Section is a variation of the popular Hi Gain American Style preamp with even higher gain and sustain 1 The combination of Volume and Gain lets you adjust the character of the channel at various volume levels for consistency of tone and character in both small and large venue sizes 2 The BYPASS feature of the Bass control byp...

Страница 2: ...wdriver in the notch at the bottom of the power cord inlet connector the drawer snaps out in a rearward direction The RedStar can accept both the larger 3AG footprint or smaller European 5mm X 20mm fuses A time delay variety SLO BLO is recommended When the export version becomes available the fuse drawer can be rotated for voltage selection make sure the correct value fuse is located on the same s...

Страница 3: ...Standby switch to make sure it is toggled downward for Standby operation 2 Toggle the main power switch to the up position this switch is located at the top of the IEC input module The front panel pilot light should be lit 3 Wait one minute and then toggle the Standby switch upwards to the Operate position 4 POWER OFF Toggle the main power switch downward there is no need to go into standby first ...

Страница 4: ...ration and again after a week or two of operation INTERNAL TRIM POTS The RedStar has 1 internal trim pot 1 PI Balance Useful for working with unmatched 12AX7 tubes in the phase inverter position Refer to qualified personnel for proper setting RedPlateAmps Warranty At RedPlateAmps we pride ourselves making products that are built to last The workmanship in your RedPlate amplifier is warranted to be...

Отзывы: