RedPlate RedLine Operations Guide 

 

 

The RedLine comes complete with a footswitch:  

FOOTSWITCH 

 

 

MASTER

 

– Light on = Master1 control is active, Light off = Master2 control is active. 

 

POWER ON/OFF PROCEDURE 

1.  Check the Standby switch to make sure it is toggled downward for Standby operation.  
2.  Toggle the main power switch to the up position (this switch is located at the top of the IEC 

input module). The front panel pilot light should be lit. 

3.  Wait one minute and then toggle the Standby switch upwards to the Operate position. 
4.  POWER OFF 

– Toggle the main power switch downward, there is no need to go into 

standby first although it will not hurt anything. 

 

MAINTENANCE SECTION 

Your RedLine amp has been designed for years of trouble free operation. The vacuum tubes 

will need to be replaced over time. We recommend new output tubes every 160 - 240 hours and 
new preamp tubes every 320 - 480 hours. 

The front and rear panels have a protective finish that can be easily scratched with abrasives 

so always use a damp soft cloth to clean them (never use paper towels). 

 

 

TUBE CHART 

 

All tube brands are acceptable, a long plate is preferred in the V5 (Phase Inverter) position. 

 

Содержание RedLine 50

Страница 1: ...nual for an understanding of all the available features or just put all the knobs at noon and play This Manual applies to RedLine models produced after 11 1 2015 Signal Path Block Diagram FRONT PANEL The RedLine is designed to imitate and surpass all of the classic British style guitar amp preamps by producing a full range of tones with plenty of character and absolute control of the overall volum...

Страница 2: ...EAR PANEL SECTION SEND and RETURN Jacks The send jack connects to the input of an external effects device and the return jack connects to the output of an external effects device The return jack interrupts the signal path so the external effects unit must mix the wet and dry signals Footswitch Jack This is a standard for footswitch connection Impedance Selector Ω Set this to the total impedance of...

Страница 3: ...ndby switch upwards to the Operate position 4 POWER OFF Toggle the main power switch downward there is no need to go into standby first although it will not hurt anything MAINTENANCE SECTION Your RedLine amp has been designed for years of trouble free operation The vacuum tubes will need to be replaced over time We recommend new output tubes every 160 240 hours and new preamp tubes every 320 480 h...

Страница 4: ... the meter at chassis ground 6 Use a small flat blade screwdriver to adjust the bias pot for the bias number as stated on the rear panel 5 MV The reading is the sum of the idle current for all EL 34 tubes 7 Recheck the reading after 10 minutes of operation and again after a week or two of operation RedPlateAmps Warranty At RedPlateAmps we pride ourselves making products that are built to last The ...

Отзывы: