![RedMax BLi200ZR Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/redmax/bli200zr/bli200zr_operators-manual_1429439008.webp)
8 – English
Troubleshooting the battery and/or the battery charger during charging
(5), (6).
Table 1: Battery
LED display
Possible faults
Possible action
Error LED
flashing
Temperature devi-
ation.
Use the battery charger only
when the surrounding tem-
perature is between 5 °C
(41 °F) and 40 °C (104 °F).
Battery is empty.
Charge the battery.
Error LED
is lit
Cell difference too
much (1 V).
Contact your service agent.
TRANSPORTATION, STORAGE
AND DISPOSAL
Transportation and storage
• The contained lithium-ion batteries are subject to the Dangerous
Goods Legislation requirements.
• For commercial transports e.g. by third parties, forwarding agents,
special requirement on packing and labeling must be observed.
• For preparation of the item being shipped, consulting an expert for
hazardous material is required. Please also observe possibly more
detailed national regulations.
•
Tape or mask off open contacts and pack up the battery in such a
manner that it cannot move around in the packing.
•
Store the equipment in a lockable area so that it is out of reach
of children and unauthorized persons. Store the battery and the
battery charger in a dry, moisture-free and frost-free space. Store
the battery where the temperature is between 5°C (41°F) and 25°C
(77°F) and never in direct sunlight.
• Be sure to store the battery separate from the battery charger.
• Do not store the battery in places where static electricity can occur.
Never store the battery in a metal box. Before longer storage
please charge the battery.
BLi200ZR_Redmax.indd 8