background image

C

211

1-717-767-6511

Ordering Information . . . . . . . . . . . . . . . . . . . 2
General Meter Specifications. . . . . . . . . . . . . 3
Installing the Meter . . . . . . . . . . . . . . . . . . . . 3
Setting the Switches . . . . . . . . . . . . . . . . . . . 4

Wiring the Meter . . . . . . . . . . . . . . . . . . . . . . 4
Reviewing the Front Buttons and Display . . . 6
Scaling the Meter . . . . . . . . . . . . . . . . . . . . . 6
Programming the Meter . . . . . . . . . . . . . . . . 7

O

RDERING

I

NFORMATION

PAXL

0

0

R0

R0 - 6 Digit Rate Meter

Meter Part Numbers

T

ABLE

O

F

C

ONTENTS

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Содержание PAXLR-PAX LITE

Страница 1: ...the programming is complete the front panel buttons can be disabled by a DIP switch setting The meter has been specifically designed for harsh industrial environments With NEMA 4X IP65 sealed bezel and extensive testing to meet CE requirements the meter provides a tough yet reliable application solution SAFETY SUMMARY All safety related regulations local codes and instructions that appear in the l...

Страница 2: ...Reviewing the Front Buttons and Display 6 Scaling the Meter 6 Programming the Meter 7 ORDERING INFORMATION PAXL 0 0 R0 R0 6 Digit Rate Meter Meter Part Numbers TABLE OF CONTENTS Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Office 650 588 9200 Outside Local Area 800 258 9200 www stevenengineering com ...

Страница 3: ...ts 2 EMI filter placed on the DC power supply when DC powered Corcom 1VB3 or Schaffner FN610 1 07 RLC LFIL0000 10 CONNECTIONS High compression cage clamp terminal block Wire Strip Length 0 3 7 5 mm Wire Gage Capacity 30 14 AWG copper wire Torque 4 5 inch lbs 0 51 N m max 11 CONSTRUCTION This unit is rated for NEMA 4X IP65 outdoor use IP20 Touch safe Installation Category II Pollution Degree 2 One ...

Страница 4: ...between a successful or troublesome installation Listed below are some EMC guidelines for successful installation in an industrial environment 1 The meter should be mounted in a metal enclosure which is properly connected to protective earth 2 Use shielded screened cables for all Signal and Control inputs The shield screen pigtail connection should be made as short as possible The connection point...

Страница 5: ...enerators Etc Magnetic Pickup Emitter Follower Current Source Switch position is application dependent 3 1 POWER WIRING AC Power Terminal 1 VAC Terminal 2 VAC DC Power Terminal 3 VDC Terminal 4 COMM Courtesy of Steven Engineering Inc 230 Ryan Way South San Francisco CA 94080 6370 Main Office 650 588 9200 Outside Local Area 800 258 9200 www stevenengineering com ...

Страница 6: ...greater accuracy multiply both Input and Display values by 10 Scaling Display 36000 Scaling Input 2 5 RATE DISPLAY OVERFLOW The rate of the input signal along with the programmed scaling values can cause the calculated rate display to exceed the meter s 6 digit capacity If this occurs the display will show to indicate an overflow condition INPUT FREQUENCY CALCULATION The meter determines the input...

Страница 7: ...ation The High Update Time is the maximum amount of time before the display is forced to zero The High Update Time must be higher than the Low Update Time and also higher than the desired slowest readable speed one divided by pulses per second The factory setting of 2 0 will force the display to zero for speeds below 0 5 Hz or one pulse every 2 seconds For more details on display updating refer to...

Отзывы: