-4-
Released 2018-06-28
Bulletin No. LPAX5-E
Drawing No. LP0489
LPAX
DISPLAY
INSTALLATION
CAUTION:
1
2
3
4
5
6
7
8
9
10
11
DISCONNECT ALL
POWER BEFORE INSTALLING OR REMOVING MODULE
SLOT
TWIST
!
WHILE FIRMLY DEPRESSING REAR FINGER TABS (TOP & BOTTOM),
INSERT SCREWDRIVER BLADE (3/16" OR 1/4") INTO NARROW SLOT
(AT THE ARROW) AND TWEIST IN THE DIRECTION SHOWN.
TO REMOVE MODULE:
MODEL LPAX
RED LION CONTROLS
YORK, PA. MADE IN U.S.A.
PAXCDC10
RS485 COMMUNICATION
12
13
14
15
- B(-)
- A(+)
- COMM
- N/C
1
2
3
4
5
6
7
8
9
10
11
~~
AC
AC
85-250VAC
50/60Hz
14VA
COMMUNICATION OPTION
ANALOG OUT OPTION
SETPOINT (SP) OPTION
MODEL PAXD
RED LION CONTROLS
YORK, PA. MADE IN U.S.A.
SEE LITERATURE FOR
JUMPER SELECTION
SIGNAL INPUTS
USER INPUTS
VOLT/OHM
CURRENT
+EXCITATION
COMM
1
2
3
N/C
COMM
!
R
-
19
17
+
18
-
+
16
ANALOG OUTPUT
PAXCDL10
RLY3
25
21
RLY2
22
COMM
RLY1
20
QUAD RELAY S.P.
PAXCDS20
0-10V
ANALOG
OUTPUT
OUTPUT ANALOG
0-20mA
24
23
COMM
RLY4
RELAYS RATED
3A @ 250VAC
(RESISTIVE LOAD)
MODULE
RETENTION
LATCH (TOP
AND BOTTOM)
MOUNTING
PANEL
PANEL
GASKET
FRONT
PANEL
MODULE RELEASE
FINGER TAB
(TOP & BOTTOM)
CASE
VENT
HOLES
REAR COVER PLATE
CAUTION
DISCONNECT
ALL POWER
BEFORE
OPENING
CONNECTED TO
MUST BE
METAL PANEL
MA2204X
E
!
CONNECT THIS STUD
TO A PROTECTIVE
EARTHING SYSTEM
MOUNTING STUDS AND NUTS
(6 PLACES)
The LPAX display is intended to be mounted into a panel or enclosure.
The display is provided with a gasket to provide a water-tight seal. The
recommended minimum panel thickness for NEMA 4/IP65 sealing is
0.060" (1.57 mm).
For panel mounting, prepare the panel cut-out to the dimensions shown.
The supplied template may be used to mark the cut-out and hole locations
on the panel. After the panel cut-out has been deburred, slide the panel
gasket over the rear of the display and onto the mounting studs. Insert the
display into the panel cut-out as illustrated in Figure 3. Install six # 10-32
keps nuts (supplied) and tighten evenly for uniform gasket compression.
Do not over-tighten the nuts.
By using additional mounting accessories, the LPAX can be surface-wall
mounted, suspended, or bottom mounted. Separate installation
instructions are provided with the mounting accessories.
Environment
And
Cleaning
3.0
WIRING
AND
PROGRAMMING
THE
DISPLAY
The display should be installed in a location that does not exceed the
maximum operating temperature and provides good air circulation. Placing
the system near devices that generate excessive heat should be avoided.
The bezel should be cleaned only with a soft cloth and neutral soap
product. Do NOT use solvents. Continuous exposure to direct sunlight may
accelerate the aging process of the bezel.
2.0
INSTALLING
THE
DISPLAY
Figure 3, Installing The LPAX Into A Panel
Once assembled, the LPAX and MPAX have all the same functions
and capabilities of our PAX Series Intelligent Panel Meters. Therefore,
you will find the appropriate PAX information packed with the MPAX
Module. Follow the instructions found in the appropriate PAX
documentation to wire and program the display for your application.
TROUBLESHOOTING
If for any reason you have trouble operating, connecting, or simply have
questions concerning your new unit, contact Red Lion’s technical support.
Email: [email protected]
Website: www.redlion.net
Inside US: +1 (877) 432-9908
Outside US: +1 (717) 767-6511
ORDERING
INFORMATION
1
Refer to “Selecting Your Display Components and Option Cards.”
Crimson
®
software is available for free download from http://www.redlion.net/
TYPE
MODEL NO.
DESCRIPTION
PART NUMBER
Display
LPAX
5-Digit Extra Large Display for Analog MPAX Modules
LPAX0500
Analog
Input
Module
MPAX
Universal DC
Input Module, AC Powered
MPAXD000
Universal DC Input Module, DC/24 VAC Powered
MPAXD010
Process
Input Module, AC Powered
MPAXP000
Process Input Module, DC/24 VAC Powered
MPAXP010
Thermocouple and RTD Module, AC Powered
MPAXT000
Thermocouple and RTD
Module, DC/24 VAC Powered
MPAXT010
AC True RMS Voltage and Current Module, AC Powered
MPAXH000
Strain Gage/Bridge Input Module, AC Powered
MPAXS000
Strain Gage Input Module, DC/24 VAC Powered
MPAXS010
Option Cards
PAXCDS
Dual Setpoint Relay Output Card
PAXCDS10
Quad Setpoint Relay Output Card
PAXCDS20
Quad Setpoint Sinking Open Collector Output Card
PAXCDS30
Quad Setpoint Sourcing Open Collector Output Card
PAXCDS40
Dual Triac/Dual SSR Drive Output Card
PAXCDS50
PAXCDC
1
RS485 Serial Communications Card with Terminal Block
PAXCDC10
Extended RS485 Serial Communications Card with Dual RJ11 Connector
PAXCDC1C
RS232 Serial Communications Card with Terminal Block
PAXCDC20
Extended RS232 Serial Communications Card with 9 Pin D Connector
PAXCDC2C
DeviceNet Communications Card
PAXCDC30
Modbus Communications Card
PAXCDC40
Extended Modbus Communications Card with Dual RJ11 Connector
PAXCDC4C
Profibus-DP Communications Card
PAXCDC50
PAXCDL
1
Analog Output Card
PAXCDL10
PAXUSB
PAX USB Programming Card
PAXUSB00
Accessories
CBLUSB
USB Programming Cable Type A-Mini B
CBLUSB01
LX
Custom Units Label
Listed Separately
ENC9
NEMA 4 Enclosure for LPAX
ENC90000
SHR
Shroud for LPAX
SHRLPAX0
MB
Mounting Bracket for LPAX
MBLPAX00