background image

8

DRAINING THE PUMP

Risk of injury or damage to equipment.

•  Do not remove priming plug, drain plug, pump housing or inlet or discharge hose fittings when pump is hot. Hot water and/or vapor 

inside could be pressurized.

If the pump is subject to freezing temperatures, pump housing must be thoroughly drained of any water to prevent damage from freezing.

1.  Allow the unit to cool completely.
2. After the unit has cooled, remove drain plug and priming plug from pump housing and drain any water left in the pump.
3. Make sure the suction and discharge lines are free of water.
4. After draining, reinstall the drain plug and priming plug.

TRANSPORTING THE PUMP

1.  Allow unit to cool completely.
2. Empty the fuel tank or close the fuel valve.
3. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact the plug.
4. Make sure that the pump is kept level to reduce the possibility of oil or fuel leakage.
5. Ensure that the pump is securely strapped down in the transport vehicle to prevent it from sliding or tipping.
6. Do not refuel the pump in or on the transport vehicle. Move the pump to its operating location and then fill the fuel tank.

STORAGE

Risk of injury or damage to equipment.

•  Do not remove priming plug, drain plug, pump housing or inlet or discharge hose fittings when pump is hot. Hot water and/or vapor inside 

could be pressurized. 

•  Store the pump in a well-ventilated area away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have a pilot 

light or other ignition source (heat, flame, sparks, etc.) because they can ignite fuel vapors.

If pump is being stored for more than 30 days:

1. Allow the unit to cool completely.
2. After the unit has cooled, remove drain plug and priming plug from pump housing and drain any water left in the pump.
3. Clean inside of pump housing per the “Cleaning” section of this manual.
4. Coat inside of pump with a light film of oil to reduce corrosion.
5. Tape up suction and discharge ports to prevent anything from accidentally entering the pump.
6. Refer to and follow instructions in the engine manufacturer's owner's manual for engine storage.
7. Cover pump and engine and store in a clean, dry area.

Содержание 4RLAG-2H

Страница 1: ... redlionproducts com EN TableOfContents Safety Instructions 2 Introduction 4 Application 4 Specifications 4 Pump Placement 5 Operation 5 Maintenance 7 Cleaning 7 Draining the Pump 8 Transporting the Pump 8 Storage 8 Troubleshooting 9 Replacement Parts 10 Limited Warranty 11 ...

Страница 2: ...tions Failuretofollowinstallation operationproceduresandallapplicablecodes mayresultinthefollowinghazards Risk of death personal injury or property damage Do not use to pump flammable or explosive fluids such as gasoline fuel oil kerosene etc Do not use in explosive atmospheres or hazardous locations as classified by the NEC ANSI NFPA70 When operating the engine on this pump produces carbon monoxi...

Страница 3: ...is cleaned up and any fuel vapors have dissipated Risk of bodily injury or equipment damage Rapid retraction kickback of the starter cord can pull your hand and arm toward the engine faster than you can let go Broken bones fractures bruises or sprains could result To minimize the occurrence of kickback pull the starter cord slowly until resistance is felt then pull rapidly to start the engine Do n...

Страница 4: ... Model 4RLAG 2H Engine Honda GX120 Air Cooled 4 Stroke OHV 118 cm3 Performance 4 0 HP 3600 rpm Fuel Type Refer to engine manufacturer s owner s manual Oil Type Refer to engine manufacturer s owner s manual Shut Off 98 ft 29 9 m Suction head max 25 ft 7 6 m Intake Size 2 MNPT 5 1 cm Discharge Size 2 MNPT 5 1 cm Maximum Flow 150 GPM 568 LPM Weight 52 Lb 23 6 kg Height 14 5 36 8 cm Width 14 25 36 2 c...

Страница 5: ...alled 10 Positiontheendofthedischargehosewhereyouwanttodischargedwatertobepumped Secure anchorthedischargehosetoavoidwhipping IMPORTANT One of the main causes of pumping problems is a leak in the suction line Even a very small leak will reduce priming and pumping performance greatly OPERATION PreparingtheEngine Refer to and follow the engine manufacturer s instructions for preparing the engine bef...

Страница 6: ...eration with a blocked inlet or discharge hose can cause water inside pump to overheat 3 Refer to the engine manufacturer s instructions for proper procedure for starting and stopping the engine 4 In a flooded suction situation the pump will discharge water almost immediately If the suction hose is above the water level being pumped it will take a few minutes to lift the water to the pump housing ...

Страница 7: ...iately for assistance 7 Checktheengineforoiland orfuelleaks Ifaleakisfound donotoperatetheengine Contacttheenginemanufacturerimmediatelyforassistance 8 Inspect for water leaks between pump and engine as well as all other sealing interfaces and have serviced as required If water is leaking the seal inside pump is worn or damaged Continued operation may cause water damage to engine 9 Inspect motor a...

Страница 8: ... vehicle to prevent it from sliding or tipping 6 Do not refuel the pump in or on the transport vehicle Move the pump to its operating location and then fill the fuel tank STORAGE Risk of injury or damage to equipment Do not remove priming plug drain plug pump housing or inlet or discharge hose fittings when pump is hot Hot water and or vapor inside could be pressurized Store the pump in a well ven...

Страница 9: ...elow the end of the suction hose The end of the suction hose must be submerged Pump will not start No fuel Add fuel per engine manufacturer s instructions Faulty spark plug Replace spark plug Fuel valve lever is in the OFF position Turn the fuel valve lever to the ON position Ignition switch is in the OFF position Turn the ignition switch to the ON position Choke is in the wrong position Slide cho...

Страница 10: ...5 F 617315 7 Pump casing A 617326 8 Gasket C 617345 9 Discharge flange C 617345 10 Flapper C 617345 11 Suction flange C 617345 12 O ring 25 5mm NBR C 617345 D 617331 13 Cap plug C 617345 D 617331 14 Roll frame E 617356 13C D 12C D 9C 8C 10C 11C 13C D 12C D 14E 7A 6B F 5F 4F 3B F 2A B F 1A Items with like identifiers are sold packaged together As a convenience all repair kits contain the fasteners ...

Страница 11: ...rand s published instructions applicable codes applicable ordinances and or with generally accepted industry standards 2 Any product that has been subject to misuse misapplication neglect alteration accident abuse tampering acts of God including lightning acts of terrorism acts of war fire improper storage or installation improper use improper maintenance or repair damage or casualty or to an exce...

Страница 12: ... REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION CIRCULATED AND SOLD BY THE BRAND AND OR 2 DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS This Limited Warranty gives you specific legal rights You may have other rights which vary according to the applicable laws and regulations Where any term of this warranty is prohibited by such laws...

Отзывы: